Lorenz Meier
|
91becef344
|
Cleanup of heartbeat handling and status printing. Ready to go mainline
|
2014-07-23 08:18:55 +02:00 |
Lorenz Meier
|
0c0b1a4c66
|
Print mavlink radio module rates
|
2014-07-23 08:18:45 +02:00 |
Lorenz Meier
|
ed9f9ec864
|
code style only: Fix indendation in mavlink.h
|
2014-07-23 08:18:34 +02:00 |
Lorenz Meier
|
1b5d4e5bd4
|
Comment out uavcan due to build breakage, will go back in ASAP
|
2014-07-22 17:42:34 +02:00 |
Lorenz Meier
|
086fc7f758
|
Merge pull request #1128 from PX4/uavcan
Basic UAVCAN support
|
2014-07-22 06:48:49 +02:00 |
Pavel Kirienko
|
940becd0c1
|
UAVCAN update: Mako dependency removed
|
2014-07-22 02:55:14 +04:00 |
Lorenz Meier
|
5bb3e92d36
|
Merge pull request #1211 from PX4/battload
Consider the throttle load for battery voltage calculation
|
2014-07-21 20:51:34 +02:00 |
Lorenz Meier
|
07d11583bb
|
Rely on theoretical value, as the closed-loop test with multimeter suggests this is the most accurate measurement
|
2014-07-21 20:21:20 +02:00 |
Lorenz Meier
|
178b0f7399
|
Cross-check with nominal values from divider
|
2014-07-21 19:25:23 +02:00 |
Lorenz Meier
|
331623bbd4
|
Fix missing line endings
|
2014-07-21 13:48:59 +02:00 |
Lorenz Meier
|
0fc73a1484
|
Fix comment, missing brace in comment
|
2014-07-21 13:46:38 +02:00 |
Lorenz Meier
|
956c084f31
|
Fit IO voltage estimation using a new dataset, cross-validated with a second unit. Pending testing
|
2014-07-21 13:31:35 +02:00 |
Lorenz Meier
|
afff123742
|
Add PX4IO voltage dataset and linear fit
|
2014-07-21 13:30:56 +02:00 |
Lorenz Meier
|
25d1cc3995
|
Final value for battery load param default
|
2014-07-21 07:35:23 +02:00 |
Lorenz Meier
|
c95de36d3a
|
commander: Add missing parameter definition
|
2014-07-20 19:42:31 +02:00 |
Lorenz Meier
|
264fe884a2
|
Fixed load voltage calculation
|
2014-07-20 16:28:44 +02:00 |
Lorenz Meier
|
3935540c7d
|
Set full voltage correctly to ensure percentage range fits. Force all users to new value by param renaming. Since this will tend to show batteries as more drained than before, this is a change in a safe direction and will not trigger unnoticed discharges.
|
2014-07-20 16:23:43 +02:00 |
Lorenz Meier
|
e21cb64553
|
Merge branch 'master' of github.com:PX4/Firmware into battload
|
2014-07-20 16:21:59 +02:00 |
Lorenz Meier
|
2685e3cfa4
|
Merge pull request #1216 from PX4/arming_feedback
Arming feedback
|
2014-07-20 16:17:29 +02:00 |
Lorenz Meier
|
a5f538dc5c
|
Commander: Print technical feedback as last resort if no feedback was provided before
|
2014-07-20 16:06:31 +02:00 |
Lorenz Meier
|
f3b8890601
|
commander: Explain sensor arming fail case to users
|
2014-07-20 14:31:23 +02:00 |
Lorenz Meier
|
b3a80025b3
|
Do not confuse operators / users with technical error messages
|
2014-07-20 14:28:24 +02:00 |
Lorenz Meier
|
5fb2a92e77
|
commander: Do not confuse developers with wrong comments, do not confuse users with not at all helpful "general error" messages.
|
2014-07-20 14:28:05 +02:00 |
Lorenz Meier
|
4c0e229347
|
Merge pull request #1214 from PX4/inav_params_descr
position_estimator_inav: parameters descriptions added
|
2014-07-19 23:21:58 +02:00 |
Anton Babushkin
|
e7d8d9c91f
|
position_estimator_inav: parameters descriptions added
|
2014-07-19 23:19:49 +02:00 |
Lorenz Meier
|
8688cad8e6
|
Merge pull request #1205 from PX4/forcefail
Force failsafe
|
2014-07-19 21:22:33 +02:00 |
Lorenz Meier
|
5d2489880c
|
Fix low voltage warning threshold to 9%, not 90%
|
2014-07-19 21:14:14 +02:00 |
Lorenz Meier
|
74f31618f2
|
report error in pwm command if any
|
2014-07-19 15:21:29 +02:00 |
Lorenz Meier
|
fd50655354
|
add missing hint to pwm usage
|
2014-07-19 15:15:10 +02:00 |
Lorenz Meier
|
0b3e300303
|
Merge branch 'forcefail' of github.com:PX4/Firmware into forcefail
|
2014-07-19 15:10:36 +02:00 |
Lorenz Meier
|
f3ec1cd580
|
pwm command: Add missing exit 0 status
|
2014-07-19 15:10:20 +02:00 |
Lorenz Meier
|
f3fe9c2fdf
|
Print force fail status
|
2014-07-19 15:09:07 +02:00 |
Lorenz Meier
|
87cc7a81ff
|
Support force fail in valid filter
|
2014-07-19 15:08:56 +02:00 |
Thomas Gubler
|
0b743a9f5c
|
parse flighttermination command
|
2014-07-19 14:39:41 +02:00 |
Thomas Gubler
|
de0dd71061
|
pwm: add missing exit
|
2014-07-19 14:39:19 +02:00 |
Lorenz Meier
|
3db78a4ab3
|
commander: Warn at 18 and 9% battery remaining instead of 25 and 10% to not trigger the warning too early (at 50%) as it was before
|
2014-07-19 14:34:19 +02:00 |
Lorenz Meier
|
3a0fc36c67
|
Consider the throttle load for battery voltage calculation
|
2014-07-19 14:12:33 +02:00 |
Thomas Gubler
|
78b8e4d59f
|
really checkout latest mavlink master
|
2014-07-19 13:23:35 +02:00 |
Thomas Gubler
|
7b3654a576
|
checkout latest mavlink master
|
2014-07-19 13:08:54 +02:00 |
Thomas Gubler
|
689536893c
|
px4io driver: force failsafe depending on actuator armed
|
2014-07-19 12:46:52 +02:00 |
Thomas Gubler
|
d7e1502a26
|
Merge remote-tracking branch 'upstream/master' into forcefail
|
2014-07-19 12:44:50 +02:00 |
Lorenz Meier
|
322089a390
|
Fix unused params
|
2014-07-19 11:29:49 +02:00 |
Lorenz Meier
|
57794925fe
|
Revert "Remove MT_ENABLED param and handles"
This reverts commit 90a5ae1afd .
|
2014-07-19 10:53:04 +02:00 |
Lorenz Meier
|
a4e1a66583
|
Revert "Remove last reference to mtecs enabled param"
This reverts commit 81f60329e4 .
|
2014-07-19 10:52:50 +02:00 |
Pavel Kirienko
|
528253e33a
|
UAVCAN update
|
2014-07-18 23:24:07 +04:00 |
Lorenz Meier
|
5c8c58a1e6
|
pwm system command: Allow to force failsave (forcefail command)
|
2014-07-18 11:19:37 +02:00 |
Lorenz Meier
|
903b482378
|
PX4IO driver: Add support to set force failsafe
|
2014-07-18 11:19:05 +02:00 |
Lorenz Meier
|
9a53fd9648
|
Add force failsafe flag
|
2014-07-18 11:18:32 +02:00 |
Thomas Gubler
|
a1a921d152
|
Merge pull request #1204 from PX4/tecs-cleanup
Remove all unused TECS parameters
|
2014-07-18 09:30:55 +02:00 |
Lorenz Meier
|
81f60329e4
|
Remove last reference to mtecs enabled param
|
2014-07-18 08:07:35 +02:00 |