2020-08-14 17:41:59 -03:00
uint64 timestamp # time since system start (microseconds)
2021-06-30 07:00:50 -03:00
bool connected # Whether or not a battery is connected, based on a voltage threshold
2020-08-14 17:41:59 -03:00
float32 voltage_v # Battery voltage in volts, 0 if unknown
2015-05-25 14:23:43 -03:00
float32 voltage_filtered_v # Battery voltage in volts, filtered, 0 if unknown
2020-08-14 17:41:59 -03:00
float32 current_a # Battery current in amperes, -1 if unknown
2016-05-10 05:17:48 -03:00
float32 current_filtered_a # Battery current in amperes, filtered, 0 if unknown
2024-02-06 12:32:09 -04:00
float32 current_average_a # Battery current average in amperes (for FW average in level flight), -1 if unknown
2015-05-25 14:23:43 -03:00
float32 discharged_mah # Discharged amount in mAh, -1 if unknown
2020-08-14 17:41:59 -03:00
float32 remaining # From 1 to 0, -1 if unknown
float32 scale # Power scaling factor, >= 1, or -1 if unknown
2021-09-16 06:15:44 -03:00
float32 time_remaining_s # predicted time in seconds remaining until battery is empty under previous averaged load, NAN if unknown
2020-08-14 17:41:59 -03:00
float32 temperature # temperature of the battery. NaN if unknown
2021-11-24 12:45:37 -04:00
uint8 cell_count # Number of cells, 0 if unknown
2020-03-25 07:27:05 -03:00
uint8 BATTERY_SOURCE_POWER_MODULE = 0
2020-03-30 05:26:11 -03:00
uint8 BATTERY_SOURCE_EXTERNAL = 1
uint8 BATTERY_SOURCE_ESCS = 2
2020-08-14 17:41:59 -03:00
uint8 source # Battery source
uint8 priority # Zero based priority is the connection on the Power Controller V1..Vn AKA BrickN-1
uint16 capacity # actual capacity of the battery
uint16 cycle_count # number of discharge cycles the battery has experienced
uint16 average_time_to_empty # predicted remaining battery capacity based on the average rate of discharge in min
uint16 serial_number # serial number of the battery pack
2022-07-27 01:33:16 -03:00
uint16 manufacture_date # manufacture date, part of serial number of the battery pack. Formatted as: Day + Month× 32 + (Year– 1980)× 512
2021-12-28 07:09:17 -04:00
uint16 state_of_health # state of health. FullChargeCapacity/DesignCapacity, 0-100%.
2020-08-14 17:41:59 -03:00
uint16 max_error # max error, expected margin of error in % in the state-of-charge calculation with a range of 1 to 100%
uint8 id # ID number of a battery. Should be unique and consistent for the lifetime of a vehicle. 1-indexed.
2021-04-11 22:27:31 -03:00
uint16 interface_error # interface error counter
2018-03-06 05:42:20 -04:00
2021-11-24 12:45:37 -04:00
float32[14] voltage_cell_v # Battery individual cell voltages, 0 if unknown
2020-08-14 17:41:59 -03:00
float32 max_cell_voltage_delta # Max difference between individual cell voltages
2017-06-29 17:45:52 -03:00
2020-08-14 17:41:59 -03:00
bool is_powering_off # Power off event imminent indication, false if unknown
2021-12-28 07:09:17 -04:00
bool is_required # Set if the battery is explicitly required before arming
2016-02-24 14:08:56 -04:00
2020-08-14 17:41:59 -03:00
uint8 BATTERY_WARNING_NONE = 0 # no battery low voltage warning active
uint8 BATTERY_WARNING_LOW = 1 # warning of low voltage
uint8 BATTERY_WARNING_CRITICAL = 2 # critical voltage, return / abort immediately
uint8 BATTERY_WARNING_EMERGENCY = 3 # immediate landing required
uint8 BATTERY_WARNING_FAILED = 4 # the battery has failed completely
2021-12-28 07:09:17 -04:00
uint8 BATTERY_STATE_UNHEALTHY = 6 # Battery is diagnosed to be defective or an error occurred, usage is discouraged / prohibited. Possible causes (faults) are listed in faults field.
uint8 BATTERY_STATE_CHARGING = 7 # Battery is charging
2016-02-24 14:08:56 -04:00
2021-12-28 07:09:17 -04:00
uint8 BATTERY_FAULT_DEEP_DISCHARGE = 0 # Battery has deep discharged
uint8 BATTERY_FAULT_SPIKES = 1 # Voltage spikes
uint8 BATTERY_FAULT_CELL_FAIL= 2 # One or more cells have failed
uint8 BATTERY_FAULT_OVER_CURRENT = 3 # Over-current
uint8 BATTERY_FAULT_OVER_TEMPERATURE = 4 # Over-temperature
uint8 BATTERY_FAULT_UNDER_TEMPERATURE = 5 # Under-temperature fault
uint8 BATTERY_FAULT_INCOMPATIBLE_VOLTAGE = 6 # Vehicle voltage is not compatible with battery one
uint8 BATTERY_FAULT_INCOMPATIBLE_FIRMWARE = 7 # Battery firmware is not compatible with current autopilot firmware
uint8 BATTERY_FAULT_INCOMPATIBLE_MODEL = 8 # Battery model is not supported by the system
uint8 BATTERY_FAULT_HARDWARE_FAILURE = 9 # hardware problem
uint8 BATTERY_WARNING_OVER_TEMPERATURE = 10 # Over-temperature
uint8 BATTERY_FAULT_COUNT = 11 # Counter - keep it as last element!
uint16 faults # Smart battery supply status/fault flags (bitmask) for health indication.
uint32 custom_faults # Bitmask indicating smart battery internal manufacturer faults, those are not user actionable.
uint8 warning # Current battery warning
uint8 mode # Battery mode. Note, the normal operation mode
uint8 BATTERY_MODE_UNKNOWN = 0 # Battery does not support a mode, or if it does, is operational
uint8 BATTERY_MODE_AUTO_DISCHARGING = 1 # Battery is auto discharging (towards storage level)
uint8 BATTERY_MODE_HOT_SWAP = 2 # Battery in hot-swap mode
uint8 BATTERY_MODE_COUNT = 3 # Counter - keep it as last element (once we're fully migrated to events interface we can just comment this)!
2020-09-24 12:01:28 -03:00
uint8 MAX_INSTANCES = 4
2021-04-11 22:27:31 -03:00
float32 average_power # The average power of the current discharge
float32 available_energy # The predicted charge or energy remaining in the battery
2022-01-24 22:24:40 -04:00
float32 full_charge_capacity_wh # The compensated battery capacity
float32 remaining_capacity_wh # The compensated battery capacity remaining
2021-04-11 22:27:31 -03:00
float32 design_capacity # The design capacity of the battery
uint16 average_time_to_full # The predicted remaining time until the battery reaches full charge, in minutes
uint16 over_discharge_count # Number of battery overdischarge
float32 nominal_voltage # Nominal voltage of the battery pack