# EFI SkyPower Driver
|
|
|
|
This driver implements support for the SkyPower range of EFI engine
|
|
control units. It supports monitoring and control of SkyPower engines.
|
|
|
|
# Parameters
|
|
|
|
The script used the following parameters:
|
|
|
|
## EFI_SP_ENABLE
|
|
|
|
this must be set to 1 to enable the driver
|
|
|
|
## EFI_SP_CANDRV
|
|
|
|
This sets the CAN scripting driver number to attach to. This is
|
|
normally set to 1 to use a CAN driver with CAN_Dx_PROTOCOL=10. To use
|
|
the 2nd scripting CAN driver set this to 2 and set CAN_Dx_PROTOCOL=12.
|
|
|
|
## EFI_SP_UPDATE_HZ
|
|
|
|
This sets the update rate of the script in Hz (how often it checks for
|
|
new data from the ECU). A value of 200 is reasonable.
|
|
|
|
## EFI_SP_THR_FN
|
|
|
|
This sets the SERVOn_FUNCTION number to monitor for throttle
|
|
command. For fixed wing forward throttle this should be set to 70. For
|
|
heli RSC control this should be set to 31. If set to zero then no
|
|
throttle control will be done by the driver.
|
|
|
|
## EFI_SPI_THR_RATE
|
|
|
|
This is the throttle output rate in Hz. A value of zero will disable
|
|
throttle control. A typical rate would be 50Hz.
|
|
|
|
## EFI_SP_START_FN
|
|
|
|
This is the RC option to use to monitor start control. This should be
|
|
set to one of the scripting RC options (from 300 to 307). Then an
|
|
RCn_OPTION should be set to the same value. When this switch goes high
|
|
the engine start function will be sent to the ECU. When this switch
|
|
goes low a engine stop will be sent. A value of 0 disables the starter
|
|
control.
|
|
|
|
## EFI_SP_GEN_FN
|
|
|
|
This is the RC option (auxiliary function) to use for generator
|
|
control. This should be set to one of the scripting RC options (from
|
|
300 to 307) if generator control is needed. Then an RCn_OPTION should
|
|
be set to the same value. When this switch goes high the generator
|
|
start function will be sent to the ECU. When this switch goes low a
|
|
generator stop will be sent. A value of 0 disables the generator
|
|
control.
|
|
|
|
## EFI_SP_MIN_RPM
|
|
|
|
This is the minimum running RPM. When set to a positive value then the
|
|
driver will monitor engine RPM when the engine is started and if it
|
|
drops below this value then an engine start will be sent to restart
|
|
the engine.
|
|
|
|
# Operation
|
|
|
|
This driver should be loaded by placing the lua script in the
|
|
APM/SCRIPTS directory on the microSD card, which can be done either
|
|
directly or via MAVFTP. The following key parameters should be set:
|
|
|
|
- SCR_ENABLE should be set to 1
|
|
- EFI_TYPE should be set to 7
|
|
|
|
then the flight controller should rebooted and parameters should be
|
|
refreshed.
|
|
|
|
Once loaded the EFI_SP parameters will appear and should be set
|
|
according to the parameter list above.
|
|
|
|
A 2 position RC switch should be setup with RCn_OPTION=300 (or the
|
|
value of EFI_SP_START_FN) to enable starter control. When that switch
|
|
goes high the engine will be started. When it goes low the engine will
|
|
be stopped.
|
|
|
|
The GCS will receive EFI_STATUS MAVLink messages which includes RPM,
|
|
cylinder head temperature, exhaust gas temperature, injection timing,
|
|
engine load, fuel consumption rate, throttle position atmospheric
|
|
pressure and ignition voltage.
|
|
|
|
Setting EFI_SP_RPM_MIN allows for automatic in-flight engine
|
|
restart. If the engine RPM drops below this EFI_SP_RPM_MIN for 2
|
|
seconds while the engine should be started then an engine start
|
|
command will be sent to restart the engine.
|