#pragma once
|
|
|
|
#include "AP_BattMonitor_config.h"
|
|
|
|
#if AP_BATTERY_INA3221_ENABLED
|
|
|
|
/*
|
|
*
|
|
* Datasheet: https://www.ti.com/lit/ds/symlink/ina3221.pdf?ts=1597369254046
|
|
*/
|
|
|
|
// The INA3221 takes two measurements for each channel: one for shunt voltage
|
|
// and one for bus voltage. Each measurement can be independently or
|
|
// sequentially measured, based on the mode setting (bits 2-0 in the
|
|
// Configuration register). When the INA3221 is in normal operating mode
|
|
// (that is, the MODE bits of the Configuration register are set to 111), the
|
|
// device continuously converts a shunt-voltage reading followed by a
|
|
// bus-voltage reading. This procedure converts one channel, and then continues
|
|
// to the shunt voltage reading of the next enabled channel, followed by the
|
|
// bus-voltage reading for that channel, and so on, until all enabled channels
|
|
// have been measured. The programmed Configuration register mode setting
|
|
// applies to all channels. Any channels that are not enabled are bypassed in
|
|
// the measurement sequence, regardless of mode setting.
|
|
|
|
|
|
// 8.3.3 Software Reset
|
|
// The INA3221 features a software reset that reinitializes the device and
|
|
// register settings to default power-up values without having to cycle power
|
|
// to the device. Use bit 15 (RST) of the Configuration register to perform a
|
|
// software reset. Setting RST reinitializes all registers and settings to the
|
|
// default power state with the exception of the power-valid output state. If a
|
|
// software reset is issued, the INA3221 holds the output of the PV pin until
|
|
// the power-valid detection sequence completes. The Power-Valid UpperLimit and
|
|
// Power-Valid Lowerlimit registers return to the default state when the
|
|
// software reset has been issued. Therefore, any reprogrammed limit registers
|
|
// are reset, resulting in the original power-valid thresholds validating the
|
|
// power-valid conditions. This architecture prevents interruption to circuitry
|
|
// connected to the powervalid output during a software reset event.
|
|
|
|
// The INA3221 has programmable conversion times for both the shunt- and
|
|
// bus-voltage measurements. The selectable conversion times for these
|
|
// measurements range from 140μs to 8.244ms.
|
|
|
|
|
|
#include "AP_BattMonitor.h"
|
|
#include "AP_BattMonitor_Backend.h"
|
|
|
|
#ifndef HAL_BATTMON_INA3221_MAX_DEVICES
|
|
#define HAL_BATTMON_INA3221_MAX_DEVICES 1
|
|
#endif
|
|
|
|
class AP_BattMonitor_INA3221 : public AP_BattMonitor_Backend
|
|
{
|
|
public:
|
|
/// Constructor
|
|
AP_BattMonitor_INA3221(AP_BattMonitor &mon,
|
|
AP_BattMonitor::BattMonitor_State &mon_state,
|
|
AP_BattMonitor_Params ¶ms);
|
|
|
|
void init() override;
|
|
|
|
/// Read the battery voltage and current. Should be called at 10hz
|
|
void read() override;
|
|
|
|
bool has_current() const override {
|
|
return true;
|
|
}
|
|
|
|
static const struct AP_Param::GroupInfo var_info[];
|
|
|
|
private:
|
|
|
|
AP_Int8 i2c_bus;
|
|
AP_Int8 i2c_address;
|
|
AP_Int8 channel;
|
|
|
|
static struct AddressDriver {
|
|
bool read_register(uint8_t addr, uint16_t &ret);
|
|
bool write_register(uint8_t addr, uint16_t val);
|
|
bool write_config(void);
|
|
void timer(void);
|
|
void register_timer();
|
|
|
|
AP_HAL::OwnPtr<AP_HAL::I2CDevice> dev;
|
|
uint8_t bus;
|
|
uint8_t address;
|
|
uint8_t channel_mask;
|
|
uint8_t dev_channel_mask;
|
|
|
|
struct StateList {
|
|
struct StateList *next;
|
|
HAL_Semaphore sem;
|
|
uint8_t channel;
|
|
|
|
bool healthy;
|
|
float voltage;
|
|
float current_amps;
|
|
float delta_mah;
|
|
float delta_wh;
|
|
uint32_t last_time_micros;
|
|
};
|
|
StateList *statelist;
|
|
|
|
} address_driver[HAL_BATTMON_INA3221_MAX_DEVICES];
|
|
static uint8_t address_driver_count;
|
|
|
|
AddressDriver::StateList *address_driver_state;
|
|
};
|
|
|
|
#endif // AP_BATTERY_INA3221_ENABLED
|