Andrew Tridgell
2b3d17d955
AP_Baro: fixed APM1 build
2014-07-14 09:50:17 +10:00
Andrew Tridgell
be02f0c34f
AP_Baro: work around occasional 0 values from MS5611
...
this was seen on the PXF board. It isn't yet known why it happens
2014-07-14 09:44:36 +10:00
Andrew Tridgell
f73ec95c39
AP_Baro_MS5611: added PROM CRC checking
...
disabled on APM2 to save flash space
2014-07-14 09:44:35 +10:00
Andrew Tridgell
e118984c26
AP_Baro: save some flash and memory on APM2
...
we don't need the I2C MS5611 driver
2014-07-08 14:21:42 +10:00
Andrew Tridgell
8a65a729f3
AP_Baro: start MS5611 at high speed
2013-11-07 12:48:17 +11:00
Andrew Tridgell
d60a68fd9c
AP_Baro: check baro at exactly 100Hz
...
prevent waits for samples
2013-10-13 11:02:53 +09:00
Andrew Tridgell
c04d9b0c03
AP_Baro: updates for AP_HAL::MemberProc
2013-09-30 21:06:42 +10:00
Andrew Tridgell
20b1131059
AP_Baro: use new scheduler API
2013-09-28 21:24:03 +10:00
Andrew Tridgell
fc119d9b80
AP_Baro: cleaned up temperature and pressure units
...
thanks to Mike McCauley for pointing this out
2013-09-21 21:30:41 +10:00
Andrew Tridgell
97b7130bb9
libraries: update license header to GPLv3
...
we switched to GPLv3 a long time ago, but neglected to update the
per-file license headers
2013-08-30 13:01:39 +10:00
James Bielman
5631f865b2
Update floating point calculations to use floats instead of doubles.
...
- Allows use of hardware floating point on the Cortex-M4.
- Added "f" suffix to floating point literals.
- Call floating point versions of stdlib math functions.
2013-01-16 13:52:01 +11:00
James Bielman
25d078e2bd
AP_Baro_MS5611: Don't panic if taking semaphore fails during init.
...
- The MPU6000 holds on to the I2C semaphore for quite some time during
init, which caused a panic when the MS5611 is also on I2C.
2013-01-10 14:22:41 -08:00
Andrew Tridgell
9b972af307
AP_Baro: skip timer if we don't get the SPI semaphore
2013-01-09 20:27:48 +11:00
James Bielman
eca1417858
AP_HAL: Add semaphores to I2C driver.
...
- Guard I2C transactions with this semaphore in the MS5611 and
HMC5843 drivers.
2013-01-04 15:43:43 -08:00
James Bielman
d84ba8ef59
Use HAL suspend/resume timer procs rather than atomic.
...
- Preparation for removing begin/end atomic.
2013-01-03 17:33:13 -08:00
Pat Hickey
5d91f342bb
AP_Baro_MS5611: uses new semaphore lib
2013-01-03 13:48:07 -08:00
James Bielman
5753ae5692
AP_Baro: Add I2C support to MS5611 driver.
2013-01-03 13:48:06 -08:00
Andrew Tridgell
c5ba33d39a
AP_Baro: fixed MS5611 semaphore handling
2012-12-21 19:33:57 +11:00
Pat Hickey
107ab1a694
AP_Baro: translated to SPI transactions
2012-12-20 14:52:32 +11:00
Pat Hickey
2c2279722b
AP_Baro_MS5611: use scheduler panic
2012-12-20 14:52:31 +11:00
Pat Hickey
bfd03ab40c
AP_Baro: robust spi device
2012-12-20 14:51:35 +11:00
Pat Hickey
eaa0a990a4
AP_Baro: MS5611 robust semaphores
2012-12-20 14:51:35 +11:00
Pat Hickey
52925b655f
AP_Baro: MS5611 uses delay in busy wait
2012-12-20 14:51:35 +11:00
Pat Hickey
c1114168e4
AP_Baro tests rebase fixups
2012-12-20 14:51:29 +11:00
Pat Hickey
668caa4a2e
Fix calls to AP_HAL::Scheduler::register_timer_process
2012-12-20 14:51:27 +11:00
Pat Hickey
5d40074e4e
AP_Baro: port to AP_HAL
2012-12-20 14:51:26 +11:00
Andrew Tridgell
e331634bc5
AP_Baro: switch to SREG = oldSREG pattern for interrupt mask/restore
2012-11-20 22:31:17 +11:00
Andrew Tridgell
e5846bd965
AP_Baro: removed _sync_access check
...
this isn't needed as the common variables are already protected by
cli()/sei()
2012-09-20 17:34:33 +10:00
uncrustify
b0003c020f
uncrustify libraries/AP_Baro/AP_Baro_MS5611.cpp
2012-08-21 19:00:18 -07:00
Andrew Tridgell
f501503eb0
AP_Baro: improved barometer averaging
...
this changes the barometer calculations to floating point. On a MS5611
this is actually about twice as fast as the previous 64 bit
calculations, but gains us more accuracy as we are able to take
advantage of sub-bit precision when we average over 8 samples.
2012-07-06 15:11:30 +10:00
Andrew Tridgell
209136386b
AP_Baro: added get_pressure_samples() interface
...
this returns how many samples were used to calculate the last pressure
2012-07-05 16:29:21 +10:00
Andrew Tridgell
057eb5e6f6
Baro: average over all pressure/temperature samples on MS5611
...
this allows us to use the MS5611 barometer at its full 100Hz sample
rate (80Hz for pressure, 20Hz for temperature). The pressure and
temperature values are averaged between reads without adding any
latency. Previously the driver would throw away values between
readings
This also fixes a race condition in reading from the SPI bus that
could lead to bad values from the barometer
2012-07-02 13:44:53 +10:00
Andrew Tridgell
c387edd74c
Baro: added get_altitude() and get_climb_rate() interfaces
...
this allows the barometer driver to calibrate and return altitude and
climb rate values. This will be used by the AHRS drift correction code
for vertical velocity
The climb rate uses a 5 point average filter
2012-06-27 16:01:50 +10:00
Andrew Tridgell
88b2139d91
Baro: added suspend/resume on init
2012-05-01 12:06:54 +10:00
justinbeech
62b104cbfa
Found free extra 256 bytes of RAM eliminate _clz use from libgcc
...
Believe it or not, changing / 2^31 to >>31 saved 256 bytes in the "d" segment.
The reason is that GCC version prior to 4.3.5 does not have a count_leading_zeros (clz) assembler macro, so it uses a 256 byte lookup table called _clz
The _clz table gets pulled in if you do 64 bit division.
This tiny change is the only place that we do long long division.
Changing to a shift saves 256 bytes of ram.
2012-02-17 09:46:05 +00:00
Jason Short
026e4a6567
change constant to float 44330.0
2012-02-15 09:10:14 -08:00
Andrew Tridgell
804332c340
AP_Baro: fixed some signed/unsigned warnings
...
and a potential bug on timer wrap
2012-02-13 21:39:18 +11:00
justinbeech
69f1613f2c
Uncommented cold temp compensation after testing. Fixed read throttle so read rate ends up nailing 100hz, not 90hz. minor commenting improvements.
2012-02-13 00:00:06 +00:00
Andrew Tridgell
7ba744a11a
I2C: convert barometer library to new I2C library
...
this also adds a healthy attribute and error checking
2011-12-28 20:41:53 +11:00
Andrew Tridgell
e7720254dd
AP_Baro: update MS5611 driver for new ap_proceduce prototype
...
this saves calling millis() quite so often
2011-12-21 23:31:38 +11:00
Andrew Tridgell
bb0f179495
AP_Baro: fixed temperature on MS5611
...
this caused a 2x scaling of altitude
2011-12-17 14:58:58 +11:00
Pat Hickey
f4aaa56b16
AP_Baro_MS5611: Asynchronous operation, plus c++ style changes.
...
Yeah, I know this was a big change to make all at once.
2011-12-11 15:21:10 -08:00
Pat Hickey
d026e48032
AP_Baro : Add init( AP_PeriodicProcess * ) method to interface & implementations
...
AP_Baro_MS5611 and AP_Baro_BMP085 implement the interface, with stubs only
2011-12-11 15:21:10 -08:00
Pat Hickey
f3ad7f3af8
Wire and SPI Init: move to sketch system.pde from libraries
...
* Wire.begin removed from AP_Baro_BMP085::init()
* SPI.begin removed from AP_Baro_MS5611::init()
* SPI.begin removed from AP_InertialSensor_MPU6000::hardware_init()
* Both Wire.begin and SPI.begin added very early in init_ardupilot in
ArduCopter/system.pde and ArduPlane/system.pde
2011-12-11 15:21:10 -08:00
Pat Hickey
f52453beed
AP_Baro_MS5611: init must also perform SPI.begin
2011-12-11 15:21:09 -08:00
Pat Hickey
64eb1889ab
AP_Baro_MS5611: CS pin is arduino pin 40
2011-12-11 15:21:09 -08:00
Pat Hickey
1832ed0355
AP_Baro_MS5611: Implement AP_Baro interface
2011-12-11 15:21:09 -08:00
Pat Hickey
fdffd69257
AP_Baro_MS5611: renamed class implementation from APM_MS5611
2011-12-11 15:21:09 -08:00
Pat Hickey
c407b0d85e
AP_Baro_MS5611.h: reorganized
...
* moved ms5611 macros to c file
* reorganized class declaration & retabbed
* made Temp, Pres, and Alt private variables.
2011-12-11 15:21:09 -08:00
Pat Hickey
34cebd8a3e
AP_Baro_MS5611: Overwrote with Jose Julio's latest files.
2011-12-11 15:21:09 -08:00
Pat Hickey
9250053bfe
Added AP_Baro and AP_Baro_MS5611 classes.
...
Incomplete and does not work.
2011-12-11 15:21:08 -08:00