Commit Graph

101 Commits

Author SHA1 Message Date
Andrew Tridgell 080d7615fc AP_BattMonitor: support EFI "battery" backend
this maps Ah to Litres and Amps to Litres/hour
2023-02-09 07:12:39 +11:00
Peter Barker 6b088c6a83 AP_BattMonitor: add and use an AP_BattMonitor_Config.h 2023-01-25 22:42:55 +11:00
Andrew Tridgell 24d4a4cf5e AP_BattMonitor: added support for INA239 SPI battery monitor 2022-12-20 10:44:52 +11:00
Henry Wurzburg 6b852e39c9 AP_BattMonitor: add synthetic current sensor,fix SITL current 2022-11-24 06:53:35 +11:00
Tom Pittenger 812128125b AP_BattMonitor: add set_temperature() by external temperature sources/libraries 2022-10-18 10:05:31 +11:00
jackhong12 4a4f361a17 all: use CLASS_NO_COPY() macro 2022-10-04 11:23:04 +11:00
TunaLobster aa2c6b8d17 AP_BattMonitor: Add macros for Fuel options
Adds macros for FuelFlow, FuelLevel_PWM, and FuelLevel_Analog. The features are enabled on all 2MB boards.
2022-08-16 09:36:31 +10:00
TunaLobster 6733f75542 AP_BattMonitor: Add Fuel Level Analog driver 2022-08-16 09:36:31 +10:00
Andrew Tridgell ba10c0ae42 AP_BattMonitor: make healthy() check all configured monitors
GCS reporting for SYS_STATUS should check all healthy, not just first
backend
2022-06-24 11:13:16 +10:00
Andrew Tridgell 9c067f360f AP_BattMonitor: added option to send resting voltage to GCS 2022-03-22 11:12:54 +11:00
Hwurzburg 95e074a7bc AP_BattMonitor: update option names in BATTMonitor in prep for expansion 2022-02-01 12:35:03 +11:00
Shiv Tyagi c34301d925 AP_BattMonitor: remove MPPT_PacketDigital from Type enum
we have removed AP_BattMonitor_MPPT_PacketDigital, hence this should be removed too
2021-12-17 20:24:25 +09:00
Shiv Tyagi b34a7e46a8 AP_BatteryMonitor: remove AP_BattMonitor_MPPT_PacketDigital class
since latest versions of PacketDigital MPPT support UAVCAN, we can remove this older class
2021-12-16 09:39:43 +09:00
Randy Mackay dea7e969bd AP_BattMonitor_UAVCAN: re-format text based fault reporting and add get_mavlink_fault_bitmask 2021-12-07 02:12:06 -08:00
Josh Henderson fb28b39206 AP_BattMonitor: remove old parameter conversion to allow setting BATT_MONITOR to 0 2021-11-16 11:58:01 +11:00
Andrew Tridgell 75dfa6bae4 AP_BattMonitor: support other INA2xx battery monitors
added parameters for I2C bus and address. Tested on INA231 and INA226

This allows any 2M flash board to use an INA2xx battery monitor
2021-11-05 14:30:43 +11:00
Iampete1 73fb871695 AP_BatteryMoniter: combine pointer loaded param tables 2021-11-02 11:12:57 +11:00
Randy Mackay d3c8a5e85f AP_BattMonitor: add torqeedo battery monitor 2021-10-19 01:30:51 -04:00
李孟晓 bf1a17825c AP_BattMonitor: Provide the time remaining 2021-10-13 18:44:05 +11:00
Andrew Tridgell 281b8eb234 AP_BattMonitor: support LTC2946 I2C battery monitoring 2021-10-12 15:47:51 +11:00
Andrew Tridgell 2903e10fc0 AP_BattMonitor: added INA231 backend
only enabled via hwdef.dat for now
2021-10-12 15:47:51 +11:00
Tatsuya Yamaguchi 1dcc5c3030 AP_BattMonitor: cope with AP_BATT_MONITOR_MAX_INSTANCES < 9 2021-09-22 18:58:12 +10:00
Willian Galvani 735e2ab651 AP_BattMonitor: change capacity_remaining_pct() to a bool 2021-09-08 17:17:41 +10:00
Josh Henderson 289264f1dd AP_BattMonitor: move analog parameters to subgroupvarptr 2021-08-03 09:36:26 +10:00
Josh Henderson e37efa45de AP_BattMonitor: add SMBus address param and create SMBus subtree 2021-08-03 09:36:26 +10:00
Dr.-Ing. Amilcar do Carmo Lucas 85666959ea AP_BattMonitor: Increase the max. nr. of supported battery cells from 12 to 14
Uses a second message, because the original message does not support any more fields
2021-06-15 09:46:26 +10:00
Josh Henderson 80a17cb97f AP_BattMonitor: get Mavlink charge state 2021-06-08 09:27:13 +10:00
Tom Pittenger a365e18420 AP_BattMonitor: add MPPT PacketDigital driver 2021-04-28 19:22:53 -07:00
Iampete1 9fdceeded3 AP_BattMoniter: add reset remaining per-instance rename existing to _mask 2021-03-31 19:21:59 +11:00
Patrick José Pereira d190fff887 AP_BattMonitor: Add missing const in member functions
Signed-off-by: Patrick José Pereira <patrickelectric@gmail.com>
2021-02-03 18:45:14 +11:00
Peter Barker 00a8a8fe8e AP_BattMonitor: use enum class For Battery Failsafe 2020-12-07 15:20:14 +11:00
Tom Pittenger 171a10e117 AP_BattMonitor: Add support for multiple UAVCAN batteries from a single node 2020-11-25 14:20:53 +11:00
Gone4Dirt 836717c0af AP_BattMonitor: Add support for AP_Generator frontend-backend 2020-11-24 12:54:52 +11:00
Nick Belanger dbe5b90398 AP_BattMonitor: Adding driver for Rotoye Batmon equipped smart batteries 2020-11-11 14:24:13 +11:00
Peter Barker 2e3ba2a4d2 AP_BattMonitor: move battery type enumeration out of parameters object 2020-08-11 13:21:52 +10:00
Peter Barker 8e708a0a32 AP_BattMonitor: add backend for generator supply 2020-07-03 08:21:42 +09:00
Randy Mackay 3e519b25a4 AP_BattMonitor: fix comments re voltage scaling 2020-06-24 10:19:15 +09:00
Randy Mackay cc6298e7ac AP_BattMonitor: SMBus Generic reads up to 12 cell voltages
Checks for the highest cell for 15 seconds and then reduces the cell voltage calls to cover only those cells that actually exist

also renames SMBus _last_cell_update_us
2020-06-24 10:19:15 +09:00
Randy Mackay 4ea565e4ed AP_BattMonitor: Maxell driver inherits from SMBus_Generic 2020-06-05 16:57:39 -07:00
Randy Mackay f869cd9aa6 AP_BattMonitor: complete rename of SMBus_Maxell to Generic 2020-06-05 16:57:39 -07:00
Randy Mackay 300c0aafb1 AP_BattMonitor: add cycle count for smbus batteries 2019-12-18 15:54:42 +11:00
Andrew Tridgell fbe69ba9ab AP_BattMonitor: support selective enable of SMBUS and fuel battery monitors 2019-12-09 21:35:00 +11:00
James e474b7dcfe AP_BattMonitor: add PWM Fuel Level Sensor
this sensor produces PWM between 1100 and 1900, giving fuel level as a
percentage
2019-08-05 11:35:16 +10:00
Michael du Breuil 0a4e3a77b3 AP_BattMonitor: Refactor interface for fetching current related data 2019-07-14 00:28:00 -07:00
Andrew Tridgell 11518857b6 AP_BattMonitor: added reset_remaining() API
used to allow battery swap before takeoff
2019-06-25 09:56:25 +10:00
Michael du Breuil e177db7dcd AP_BattMonitor: Remove unused method, make some public functions private 2019-04-26 08:07:19 +10:00
Andrew Tridgell 5571a84a49 AP_BattMonitor: added a "battery" backend for liquid fuel flow
This is for sensors that give a pulse for each fixed volume of fuel.

Output is:
    - current in Amps maps to in litres/hour
    - consumed mAh is in consumed millilitres
    - fixed 1.0v voltage
2019-03-19 11:35:59 +11:00
Michael du Breuil d96aad86a5 AP_BattMonitor: Make type() const 2019-03-11 22:42:59 +00:00
Tom Pittenger 8ef4616bc2 AP_BattMonitor: unify singleton naming to _singleton and get_singleton() 2019-02-10 19:09:58 -07:00
Matt 134e7fb81c AP_BattMonitor: Add powering off mavlink broadcast 2019-01-28 15:35:04 -07:00