Peter Barker
616c129f57
AP_BattMonitor: use corrected version of send_to_components
2020-02-05 10:51:29 +11:00
James
e474b7dcfe
AP_BattMonitor: add PWM Fuel Level Sensor
...
this sensor produces PWM between 1100 and 1900, giving fuel level as a
percentage
2019-08-05 11:35:16 +10:00
Pierre Kancir
b67bab01f6
AP_BattMonitor: pass mavlink_message_t by const reference
2019-07-16 20:51:42 +10:00
Michael du Breuil
0a4e3a77b3
AP_BattMonitor: Refactor interface for fetching current related data
2019-07-14 00:28:00 -07:00
Andrew Tridgell
88111ef81a
AP_BattMonitor: reset failsafe flags when we reset battery remaining
2019-06-25 09:56:25 +10:00
Andrew Tridgell
11518857b6
AP_BattMonitor: added reset_remaining() API
...
used to allow battery swap before takeoff
2019-06-25 09:56:25 +10:00
Michael du Breuil
cc7d13e9ef
AP_BattMonitor: Remove param ignore flags
2019-06-11 10:28:45 +10:00
Tom Pittenger
9aa1fe6dc5
AP_BattMonitor: rename dataflash to logger
2019-03-28 16:40:57 +11:00
Andrew Tridgell
5571a84a49
AP_BattMonitor: added a "battery" backend for liquid fuel flow
...
This is for sensors that give a pulse for each fixed volume of fuel.
Output is:
- current in Amps maps to in litres/hour
- consumed mAh is in consumed millilitres
- fixed 1.0v voltage
2019-03-19 11:35:59 +11:00
Tom Pittenger
8ef4616bc2
AP_BattMonitor: unify singleton naming to _singleton and get_singleton()
2019-02-10 19:09:58 -07:00
Peter Barker
ef699367d5
AP_BattMonitor: correct use of random stack data
2019-01-29 11:36:38 +09:00
Matt
134e7fb81c
AP_BattMonitor: Add powering off mavlink broadcast
2019-01-28 15:35:04 -07:00
Peter Barker
6fc76a32af
GLOBAL: use AP::logger() and strip redundant Log_ from methods
2019-01-18 18:08:20 +11:00
Peter Barker
b47733142f
GLOBAL: rename DataFlash_Class to AP_Logger
2019-01-18 18:08:20 +11:00
Andrew Tridgell
25247433dc
AP_BattMonitor: added Sum backend type
...
this is used to combine battery monitors into a single reporting
unit. It operates on all instances beyond itself
2018-11-30 13:02:35 +11:00
Andrew Tridgell
4673fd8c7c
AP_BattMonitor: fix problem with BATT_MONITOR=0 and BATT2_MONITOR=N
...
this fixes a problem that came up with a user where they had
BATT_MONITOR=0 and BATT2_MONITOR=7. They did not get any battery
monitoring.
There are several ways to tackle this, but this is the simplest
2018-11-26 13:27:02 +11:00
Andrew Tridgell
1a5d60609d
AP_BattMonitor: added BATT_MONITOR_DEFAULT option
...
this is for boards with builtin current and voltage monitoring
2018-10-31 20:30:35 +11:00
Peter Barker
9923bd1fd2
AP_BattMonitor: use sizeof(array) in place of constant
2018-10-21 07:54:30 +11:00
Michael du Breuil
8b3d993b1e
AP_BattMonitor: Enable 9 battery monitors
2018-10-09 00:44:46 +01:00
Michael du Breuil
0137d6543f
AP_BattMonitor: Allow AP_BattMonitor to run arming checks
2018-10-09 00:44:46 +01:00
Michael du Breuil
1bb4f07365
AP_BattMonitor: Move failsafe checks to the backend
2018-10-09 00:44:46 +01:00
Siddharth Purohit
6e85003b56
AP_BattMonitor: move BattInfo message subscription and handling to AP_BattMonitor
2018-08-29 22:54:59 +01:00
Michael du Breuil
fd9f9cdfe0
AP_BattMonitor: Removed the need to set the battery_voltage flag
2018-08-01 09:22:09 +10:00
Andrew Tridgell
dc9ae42067
AP_BattMonitor: added ESC telemetry virtual battery
...
this aggregates all BLHeli ESCs into a single virtual battery
2018-06-19 09:36:03 +10:00
Randy Mackay
bb9b866c7f
AP_BattMonitor: resolve compiler warning re init order
2018-03-28 15:08:54 +09:00
Michael du Breuil
4a11093ebb
AP_BattMonitor: Support critical and low battery failsafes
...
Also removes the example script, as it was broken, and causing more
headaches then it was worth
2018-03-27 22:12:21 +01:00
Dr.-Ing. Amilcar Do Carmo Lucas
6cbeb73d1b
AP_BattMonitor: NFC rename functions and variables to match their functionality
2018-03-03 17:16:34 +00:00
DOMINATOR\Eugene
fcccc0174b
AP_BattMonitor: UAVCAN battery information added
2018-03-02 11:48:00 +12:00
Holger Steinhaus
7383552ebc
AP_BatteryMonitor: count mWh spent since powerup
2018-02-06 20:00:16 -07:00
Michael du Breuil
03bf247d36
AP_BattMonitor: Create a battery singleton
...
Also logs battery data from the read function directly
2018-02-06 00:11:32 +00:00
Michael du Breuil
8712fbd55d
AP_BattMonitor: Move per battery params into a containing class
2018-01-17 22:21:55 +00:00
Michael du Breuil
bb0d43d03c
AP_BattMonitor: Remove unneeded memebers
...
is_powering_off was only used for solo, and was just an intermediate
copy before updating notify
2018-01-17 22:21:55 +00:00
Andrew Tridgell
08346deed5
AP_BattMonitor: run SMBus batteries at 100kHz
...
use longer timeouts and SMBUS mode. This fixes the SMBus battery
support for Solo on ChibiOS
2018-01-15 11:46:02 +11:00
Patrick José Pereira
73a76455d2
AP_BattMonitor: Solve typo in BATT2 description
...
Signed-off-by: Patrick José Pereira <patrickelectric@gmail.com>
2017-10-31 09:32:03 +09:00
Francisco Ferreira
a83457ab07
AP_BattMonitor: complement commit d3314d7684
by adding to second battery monitor too
2017-06-26 13:41:12 +01:00
fsherratt
d3314d7684
AP_BattMonitor: param desc explicitly list Pixhawk 2 PM1 pins
...
There is confusion over which pins to use with the pixhawk 2, updated documentation to explicitly state the PM1 pins as being the same as the original pixhawk
2017-06-24 11:01:03 +09:00
Randy Mackay
7a2d8fd5fd
AP_BattMonitor: add has_cell_voltages method
2017-06-06 14:57:04 +09:00
Randy Mackay
6d8dc0fccf
AP_BattMonitor: replace int with uint8_t
...
non-functional change
2017-06-06 14:57:04 +09:00
Leonard Hall
d5e898156f
AP_BattMonitor: allow using resting voltage for failsafe
2017-06-06 14:57:04 +09:00
Leonard Hall
8709fe58ec
AP_BattMonitor: resistance learning
2017-06-06 14:57:04 +09:00
Randy Mackay
f64777849f
AP_BattMonitor: rename VOLT_TIMER to LOW_TIMER
2017-06-06 14:57:04 +09:00
Randy Mackay
989677ddfd
AP_BattMonitor: move has_current to backend
2017-06-06 14:57:04 +09:00
Francisco Ferreira
9c027713d1
AP_BattMonitor: update current/voltage parameter documentation
...
Remove information for old APM boards
Correct information for The Cube (Pixhawk 2.1) Power2 port
2017-05-19 01:19:23 +01:00
Dr.-Ing. Amilcar Do Carmo Lucas
25cfee9824
AP_BattMonitor: Use SI units conventions in parameter units
...
Follow the rules from:
http://physics.nist.gov/cuu/Units/units.html
http://physics.nist.gov/cuu/Units/outside.html
and
http://physics.nist.gov/cuu/Units/checklist.html
one further constrain is that only printable (7bit) ASCII characters are allowed
2017-05-17 18:07:25 +10:00
Andrew Tridgell
d4e6720b01
AP_BattMonitor: added BATT_VOLT_TIMEO
...
this is useful for aircraft with very low C batteries, to prevent a low
voltage failsafe on takeoff. For long endurance aircraft low C batteries
are often used, and the voltage sags a lot on takeoff, but it fine for
the rest of the flight
2017-04-28 17:40:18 +10:00
Michael du Breuil
f919c409bb
AP_BattMonitor: Remove redundant state copy
...
Every backend stored a instance reference, which wasn't used in most locations
which is redundant given that the state already tracks the instance for us as
well.
2017-04-28 00:36:10 +01:00
Michael du Breuil
3ab3face9b
AP_BattMonitor: SMBus: Read serial number
2017-04-28 00:36:10 +01:00
Michael du Breuil
121ebebfef
AP_BattMonitor: Add temperature interface
2017-04-19 14:17:24 +01:00
Michael du Breuil
e39ae6d48c
AP_BattMonitor: Add cell monitoring
2017-04-19 14:17:24 +01:00
Andre Kjellstrup
94eabed583
AP_BattMonitor: update volt and curr pin param descriptions
2017-04-13 13:30:23 +09:00