#include "AP_BattMonitor_config.h"
|
|
|
|
#if AP_BATTERY_SCRIPTING_ENABLED
|
|
|
|
#include "AP_BattMonitor_Scripting.h"
|
|
|
|
#define AP_BATT_MONITOR_SCRIPTING_TIMEOUT_US 5000000
|
|
|
|
bool AP_BattMonitor_Scripting::capacity_remaining_pct(uint8_t &percentage) const
|
|
{
|
|
if (internal_state.capacity_remaining_pct != UINT8_MAX) {
|
|
percentage = internal_state.capacity_remaining_pct;
|
|
return true;
|
|
}
|
|
// Fall back to default implementation
|
|
return AP_BattMonitor_Backend::capacity_remaining_pct(percentage);
|
|
}
|
|
|
|
bool AP_BattMonitor_Scripting::get_cycle_count(uint16_t &cycles) const
|
|
{
|
|
if (internal_state.cycle_count == UINT16_MAX) {
|
|
return false;
|
|
}
|
|
cycles = internal_state.cycle_count;
|
|
return true;
|
|
}
|
|
|
|
// Called by frontend to update the state. Called at 10Hz
|
|
void AP_BattMonitor_Scripting::read()
|
|
{
|
|
WITH_SEMAPHORE(sem);
|
|
|
|
// Check for timeout, to prevent a faulty script from appearing healthy
|
|
if (last_update_us == 0 || AP_HAL::micros() - last_update_us > AP_BATT_MONITOR_SCRIPTING_TIMEOUT_US) {
|
|
_state.healthy = false;
|
|
return;
|
|
}
|
|
|
|
if (_state.last_time_micros == last_update_us) {
|
|
// No new data
|
|
return;
|
|
}
|
|
|
|
/*
|
|
the script can fill in voltages up to 32 cells, for mavlink reporting
|
|
the extra cell voltages get distributed over the max of 14 for mavlink
|
|
*/
|
|
for (uint8_t i = 0; i < MIN(AP_BATT_MONITOR_CELLS_MAX,internal_state.cell_count); i++) {
|
|
_state.cell_voltages.cells[i] = internal_state.cell_voltages[i];
|
|
}
|
|
_state.voltage = internal_state.voltage;
|
|
if (!isnan(internal_state.current_amps)) {
|
|
_state.current_amps = internal_state.current_amps;
|
|
}
|
|
if (!isnan(internal_state.consumed_mah)) {
|
|
_state.consumed_mah = internal_state.consumed_mah;
|
|
}
|
|
// Overide integrated consumed energy with script value if it has been set
|
|
if (!isnan(internal_state.consumed_wh)) {
|
|
_state.consumed_wh = internal_state.consumed_wh;
|
|
}
|
|
if (!isnan(internal_state.temperature)) {
|
|
_state.temperature = internal_state.temperature;
|
|
}
|
|
|
|
_state.healthy = internal_state.healthy;
|
|
|
|
// Update the timestamp (has to be done after the consumed_mah calculation)
|
|
_state.last_time_micros = last_update_us;
|
|
}
|
|
|
|
bool AP_BattMonitor_Scripting::handle_scripting(const BattMonitorScript_State &battmon_state)
|
|
{
|
|
WITH_SEMAPHORE(sem);
|
|
internal_state = battmon_state;
|
|
const uint32_t now_us = AP_HAL::micros();
|
|
uint32_t dt_us = now_us - last_update_us;
|
|
if (last_update_us != 0 && !isnan(internal_state.current_amps) && isnan(internal_state.consumed_mah)) {
|
|
AP_BattMonitor_Backend::update_consumed(_state, dt_us);
|
|
}
|
|
last_update_us = now_us;
|
|
return true;
|
|
}
|
|
|
|
#endif // AP_BATTERY_SCRIPTING_ENABLED
|