ardupilot/libraries/AP_Generator/AP_Generator_RichenPower.h

218 lines
6.6 KiB
C++

// -*- tab-width: 4; Mode: C++; c-basic-offset: 4; indent-tabs-mode: nil -*-
#pragma once
#include "AP_Generator_config.h"
#if AP_GENERATOR_RICHENPOWER_ENABLED
#include "AP_Generator_Backend.h"
#include <AP_Logger/AP_Logger_config.h>
#include <AP_Common/AP_Common.h>
#include <stdint.h>
#include <stdio.h>
/*
* Example setup:
* param set SERIAL2_PROTOCOL 30 # Generator protocol
* param set SERIAL2_BAUD 9600
* param set RC9_OPTION 85 # pilot directive for generator
* param set SERVO8_FUNCTION 42 # autopilot directive to generator
*/
class AP_Generator_RichenPower : public AP_Generator_Backend
{
public:
// constructor
using AP_Generator_Backend::AP_Generator_Backend;
// init should be called at vehicle startup to get the generator library ready
void init(void) override;
// update should be called regularly to update the generator state
void update(void) override;
// methods to control the generator state:
bool stop(void) override;
bool idle(void) override;
bool run(void) override;
// method to send a GENERATOR_STATUS mavlink message
void send_generator_status(const GCS_MAVLINK &channel) override;
// prearm checks to ensure generator is good for arming. Note
// that if the generator has never sent us a message then these
// automatically pass!
bool pre_arm_check(char *failmsg, uint8_t failmsg_len) const override;
// Update front end with voltage, current, and rpm values
void update_frontend_readings(void);
// healthy returns true if the generator is not present, or it is
// present, providing telemetry and not indicating an errors.
bool healthy() const override;
private:
// read - read serial port, return true if a new reading has been found
bool get_reading();
AP_HAL::UARTDriver *uart;
// methods and state to record pilot desired runstate and actual runstate:
enum class RunState {
STOP = 17,
IDLE = 18,
RUN = 19,
};
RunState pilot_desired_runstate = RunState::STOP;
RunState commanded_runstate = RunState::STOP; // output is based on this
void set_pilot_desired_runstate(RunState newstate) {
// GCS_SEND_TEXT(MAV_SEVERITY_INFO, "RichenPower: Moving to state (%u) from (%u)\n", (unsigned)newstate, (unsigned)runstate);
pilot_desired_runstate = newstate;
}
void update_runstate();
// boolean so we can emit the RichenPower protocol version once
bool protocol_information_anounced;
// reported mode from the generator:
enum class Mode {
IDLE = 0,
RUN = 1,
CHARGE = 2,
BALANCE = 3,
OFF = 4,
};
// un-packed data from the generator:
struct Reading {
uint32_t runtime; //seconds
uint32_t seconds_until_maintenance;
uint16_t errors;
uint16_t rpm;
float output_voltage;
float output_current;
Mode mode;
};
#if HAL_LOGGING_ENABLED
// method and state to write and entry to the onboard log:
void Log_Write();
uint32_t last_logged_reading_ms;
#endif
struct Reading last_reading;
uint32_t last_reading_ms;
const uint8_t HEADER_MAGIC1 = 0xAA;
const uint8_t HEADER_MAGIC2 = 0x55;
const uint8_t FOOTER_MAGIC1 = 0x55;
const uint8_t FOOTER_MAGIC2 = 0xAA;
// reported errors from the generator:
enum class Errors { // bitmask
MaintenanceRequired = 0,
StartDisabled = 1,
Overload = 2,
LowVoltageOutput = 3,
LowBatteryVoltage = 4,
LAST
};
const char *error_strings[5] = {
"MaintenanceRequired",
"StartDisabled",
"Overload",
"LowVoltageOutput",
"LowBatteryVoltage",
};
static_assert(ARRAY_SIZE(error_strings) == (uint8_t)Errors::LAST,
"have error string for each error");
// RichenPower data packet format:
struct PACKED RichenPacket {
uint8_t headermagic1;
uint8_t headermagic2;
uint16_t version;
uint8_t runtime_minutes;
uint8_t runtime_seconds;
uint16_t runtime_hours;
uint16_t seconds_until_maintenance_high;
uint16_t seconds_until_maintenance_low;
uint16_t errors;
uint16_t rpm;
uint16_t throttle;
uint16_t idle_throttle;
uint16_t output_voltage;
uint16_t output_current;
uint16_t dynamo_current;
uint8_t unknown1;
uint8_t mode;
uint8_t unknown6[38]; // "data"?!
uint16_t checksum;
uint8_t footermagic1;
uint8_t footermagic2;
};
union RichenUnion {
uint8_t parse_buffer[70];
struct RichenPacket packet;
};
RichenUnion u;
// number of bytes currently in the buffer
uint8_t body_length;
// move the expected header bytes into &buffer[0], adjusting
// body_length as appropriate.
void move_header_in_buffer(uint8_t initial_offset);
// a simple heat model to avoid the motor moving to run too fast
// or being stopped before cooldown. The generator itself does
// not supply temperature via telemetry, so we fake one based on
// RPM.
uint32_t last_heat_update_ms;
float heat;
void update_heat();
// returns true if the generator should be allowed to move into
// the "run" (high-RPM) state:
bool generator_ok_to_run() const;
// returns an amount of synthetic heat required for the generator
// to move into the "run" state:
static constexpr float heat_required_for_run();
// approximate run and idle speeds for the generator:
static const uint16_t RUN_RPM = 15000;
static const uint16_t IDLE_RPM = 6000;
static constexpr float heat_environment_loss_factor = 0.005f;
// powf is not constexpr, so we create a const for it:
// powf(1.0f-heat_environment_loss_factor, 30)
static constexpr float heat_environment_loss_30s = 0.860384;
static constexpr float heat_environment_loss_60s = 0.740261;
// boolean so we can announce we've stopped the generator due to a
// crash just once:
bool vehicle_was_crashed;
// data and methods to handle time-in-idle-state:
uint32_t idle_state_start_ms;
uint32_t time_in_idle_state_ms() const {
if (idle_state_start_ms == 0) {
return 0;
}
return AP_HAL::millis() - idle_state_start_ms;
}
// check if the generator requires maintenance and send a message if it does:
void check_maintenance_required();
// if we are emitting warnings about the generator requiring
// maintenamce, this is the last time we sent the warning:
uint32_t last_maintenance_warning_ms;
};
#endif // AP_GENERATOR_RICHENPOWER_ENABLED