Commit Graph

286 Commits

Author SHA1 Message Date
Andrew Tridgell b1da3467c4 AP_BattMonitor: fixed a segv with BATT_MONITOR=14
this causes a hang on boot on some boards
2022-01-31 19:41:01 +09:00
Mohammad Hefny 72294648bf AP_Batt: link to battery monitor 2021-11-29 19:02:57 +09:00
bugobliterator ae0d11a26d AP_BattMonitor: use separate register_driver method while contructing CAN Driver 2021-08-14 11:05:37 +09:00
Peter Barker 819c331acd AP_BattMonitor: correct static_assert call 2021-06-28 11:05:00 +09:00
Michael du Breuil 0de9d3e759 AP_BattMonitor: Rearrange battery parameters to reduce memory usage
Saves 8 bytes per Params instance, which we have 9 of on every vehicle,
for a total saving of 72 bytes
2021-06-22 10:08:02 +10:00
Iampete1 cab8274690 AP_BattMoniter: log in Ah and Wh, add percentage to log 2021-06-22 09:19:40 +10:00
Iampete1 8ea9803193 AP_BatteryMoniter: fix mah to wah conversion 2021-06-22 09:19:40 +10:00
Andy Piper 3e6d8357e9 AP_BattMonitor: zero consumption total before recalculating
add reset function to ESC backend.
2021-06-16 17:48:47 +10:00
Peter Barker 278dc4a09b AP_BattMonitor: add cells 13 and 14 for SITL only
Allows for testing higher-cell-count scenarios
2021-06-15 09:46:26 +10:00
Peter Barker bf10b454d1 AP_BattMonitor: add assertion to avoid memory over-read 2021-06-15 09:46:26 +10:00
Peter Barker bf9937489b AP_BattMonitor: switch to Log_Write for BCL2
Just for the flash savings on smaller boards
2021-06-15 09:46:26 +10:00
Dr.-Ing. Amilcar do Carmo Lucas 85666959ea AP_BattMonitor: Increase the max. nr. of supported battery cells from 12 to 14
Uses a second message, because the original message does not support any more fields
2021-06-15 09:46:26 +10:00
Tom Pittenger adccc3deb7 AP_BattMonitor: add support for AP_Periph MPPT driver 2021-06-09 18:36:18 +10:00
李孟晓 27089b4d2b AP_BattMonitor: Fix the comment of BATTx_OPTIONS 2021-06-08 11:16:19 +10:00
Josh Henderson 80a17cb97f AP_BattMonitor: get Mavlink charge state 2021-06-08 09:27:13 +10:00
James O'Shannessy 89e4df485a AP_BattMonitor: Record and report UAVCAN Battery Info temperature correctly 2021-06-01 12:35:24 +10:00
Andy Piper 71e7f7e476 AP_BattMonitor: refector to use AP_ESC_Telem
rename AP_BattMonitor_BLHeliESC -> AP_BattMonitor_ESC
record volts, amps and consumption as floats
Correct ESC-telemetry-based voltage and temperature (<amilcar.lucas@iav.de>)
Correct ESC-telemetry-based voltage and temperature when less than 12 ESCs are used (<amilcar.lucas@iav.de>)
fix jumps in consumed current (<amilcar.lucas@iav.de>)
Implement temperature readings (<amilcar.lucas@iav.de>)
Fix temperature scaling (<amilcar.lucas@iav.de>)
2021-05-12 17:01:11 +10:00
Tom Pittenger b62ab14791 AP_BattMonitor: prepare MPPT driver for AP_Periph 2021-04-28 19:22:53 -07:00
Tom Pittenger a7f81c838f AP_BattMonitor: make virtual Backend.init() optional to fix CANDriver.init(uint8, uint8) ambiguitiy 2021-04-28 19:22:53 -07:00
Tom Pittenger a365e18420 AP_BattMonitor: add MPPT PacketDigital driver 2021-04-28 19:22:53 -07:00
Iampete1 9fdceeded3 AP_BattMoniter: add reset remaining per-instance rename existing to _mask 2021-03-31 19:21:59 +11:00
Michael du Breuil e5de148ad1 AP_BattMonitor: Fix nullptr deref when resetting a battery 2021-03-30 09:47:44 +11:00
Peter Barker 84953c2e39 AP_BattMonitor: fix constexpr-and-MIN don't get along bug
lib/libArduCopter_libs.a(AP_BattMonitor_SMBus_NeoDesign.cpp.0.o): In function `AP_BattMonitor_SMBus_NeoDesign::timer()':
/home/pbarker/rc/ardupilot/build/sitl/../../libraries/AP_BattMonitor/AP_BattMonitor_SMBus_NeoDesign.cpp:27: undefined reference to `AP_BattMonitor_SMBus_NeoDesign::max_cell_count'
collect2: error: ld returned 1 exit status
2021-02-04 09:17:57 +11:00
Michael du Breuil f854477efe AP_BattMonitor: Limit the scope of possible corruption if the NeoDesigns gets a bad cell count 2021-02-03 19:21:39 +11:00
Patrick José Pereira d190fff887 AP_BattMonitor: Add missing const in member functions
Signed-off-by: Patrick José Pereira <patrickelectric@gmail.com>
2021-02-03 18:45:14 +11:00
李孟晓 40dbb316c1 AP_BattMonitor: ignore SoC option for UAVCAN devices 2021-01-13 18:30:53 +11:00
Josh Henderson e91953fa3b AP_BattMonitor: move log BAT & BCL into AP_BattMonitor 2021-01-12 17:43:55 +11:00
Josh Henderson dfa8e55622 AP_BattMonitor: add has_temperature method to Backend 2021-01-12 17:43:55 +11:00
李孟晓 aae2d0082d AP_BattMonitor_UAVCAN: Fix issue with multiple batteries not working 2020-12-16 12:44:21 +11:00
Peter Barker 00a8a8fe8e AP_BattMonitor: use enum class For Battery Failsafe 2020-12-07 15:20:14 +11:00
Tom Pittenger 171a10e117 AP_BattMonitor: Add support for multiple UAVCAN batteries from a single node 2020-11-25 14:20:53 +11:00
Tom Pittenger 48e2b78cab AP_BattMonitor: fix compile for AP_Periph 2020-11-25 14:20:53 +11:00
Gone4Dirt 836717c0af AP_BattMonitor: Add support for AP_Generator frontend-backend 2020-11-24 12:54:52 +11:00
Nick Belanger dbe5b90398 AP_BattMonitor: Adding driver for Rotoye Batmon equipped smart batteries 2020-11-11 14:24:13 +11:00
Rishabh cd8404f80c AP_BattMonitor: Update @value field in param to be increasing order 2020-10-27 17:15:04 +11:00
Peter Barker 4d59939db6 AP_BattMonitor: create and use new AP_HAL::PWMSource object 2020-09-08 16:10:50 +10:00
Siddharth Purohit 9820ea9023 AP_BattMonitor: move to using CANManager library 2020-08-19 17:31:09 +10:00
Peter Barker 2e3ba2a4d2 AP_BattMonitor: move battery type enumeration out of parameters object 2020-08-11 13:21:52 +10:00
Peter Barker 8e708a0a32 AP_BattMonitor: add backend for generator supply 2020-07-03 08:21:42 +09:00
Henry Wurzburg a3f0ce0a87 AP_BattMonitor: fix parameters appearing in wiki param list erroneously 2020-06-30 16:24:19 +10:00
Randy Mackay 77d6b19d86 AP_BattMonitor: Generic driver timeout definition in seconds
also remove unnecessary init of local data variable
also change assert to be more forgiving
2020-06-24 10:19:15 +09:00
Randy Mackay 3e519b25a4 AP_BattMonitor: fix comments re voltage scaling 2020-06-24 10:19:15 +09:00
Randy Mackay cc6298e7ac AP_BattMonitor: SMBus Generic reads up to 12 cell voltages
Checks for the highest cell for 15 seconds and then reduces the cell voltage calls to cover only those cells that actually exist

also renames SMBus _last_cell_update_us
2020-06-24 10:19:15 +09:00
Randy Mackay 9f26bd0a67 AP_BattMonitor: TYPE param swap for SMBus-Maxell and SMBus-Generic
Generic becomes type "7" which was previously Maxell.  Maxell becomes type 16
2020-06-05 16:57:39 -07:00
Randy Mackay 2396a8176c AP_BattMonitor: comment fix 2020-06-05 16:57:39 -07:00
Randy Mackay 268c67d12d AP_BattMonitor: correct Maxell capacity 2020-06-05 16:57:39 -07:00
Randy Mackay 3de2dff6e3 AP_BattMonitor: simplify SMBus driver includes 2020-06-05 16:57:39 -07:00
Randy Mackay 4ea565e4ed AP_BattMonitor: Maxell driver inherits from SMBus_Generic 2020-06-05 16:57:39 -07:00
Randy Mackay f869cd9aa6 AP_BattMonitor: complete rename of SMBus_Maxell to Generic 2020-06-05 16:57:39 -07:00
Randy Mackay c13c037f7b AP_BattMonitor: rename SMBus_Maxell to Generic 2020-06-05 16:57:39 -07:00