Andrew Tridgell
4d821b2c91
AP_BattMonitor: added get_cell_voltage() for scripting
2023-10-25 07:31:24 +11:00
Lokesh Ramina
b7a0f47853
AP_BATTMonitor: Reserve ID 28 for AD7091R5 I2C ADC
...
Reserving an ID for a Battmonitor type which reads the analog value from an I2C ADC IC.
2023-08-03 13:03:51 +10:00
Peter Barker
e363d6dfa5
AP_BattMonitor: don't check MINIMIZE_FEATURES when also checking BOARD_FLASH_SIZE
...
we have an assertion that no board with >1MB of flash is minimized
2023-04-15 09:33:35 +10:00
Andrew Tridgell
11a2f5ed9c
AP_BattMonitor: rename more variables, types and defines
2023-04-11 10:31:31 +10:00
Andy Piper
d565a378b7
AP_BattMonitor: support configuring battery #2 in hwdef
2023-03-15 18:51:37 +11:00
Tom Pittenger
f413f82345
AP_BattMonitor: add external MPPT on-off control
2023-03-07 11:42:24 +11:00
Andrew Tridgell
080d7615fc
AP_BattMonitor: support EFI "battery" backend
...
this maps Ah to Litres and Amps to Litres/hour
2023-02-09 07:12:39 +11:00
Peter Barker
6b088c6a83
AP_BattMonitor: add and use an AP_BattMonitor_Config.h
2023-01-25 22:42:55 +11:00
Andrew Tridgell
24d4a4cf5e
AP_BattMonitor: added support for INA239 SPI battery monitor
2022-12-20 10:44:52 +11:00
Henry Wurzburg
6b852e39c9
AP_BattMonitor: add synthetic current sensor,fix SITL current
2022-11-24 06:53:35 +11:00
Tom Pittenger
812128125b
AP_BattMonitor: add set_temperature() by external temperature sources/libraries
2022-10-18 10:05:31 +11:00
jackhong12
4a4f361a17
all: use CLASS_NO_COPY() macro
2022-10-04 11:23:04 +11:00
TunaLobster
aa2c6b8d17
AP_BattMonitor: Add macros for Fuel options
...
Adds macros for FuelFlow, FuelLevel_PWM, and FuelLevel_Analog. The features are enabled on all 2MB boards.
2022-08-16 09:36:31 +10:00
TunaLobster
6733f75542
AP_BattMonitor: Add Fuel Level Analog driver
2022-08-16 09:36:31 +10:00
Andrew Tridgell
ba10c0ae42
AP_BattMonitor: make healthy() check all configured monitors
...
GCS reporting for SYS_STATUS should check all healthy, not just first
backend
2022-06-24 11:13:16 +10:00
Andrew Tridgell
9c067f360f
AP_BattMonitor: added option to send resting voltage to GCS
2022-03-22 11:12:54 +11:00
Hwurzburg
95e074a7bc
AP_BattMonitor: update option names in BATTMonitor in prep for expansion
2022-02-01 12:35:03 +11:00
Shiv Tyagi
c34301d925
AP_BattMonitor: remove MPPT_PacketDigital from Type enum
...
we have removed AP_BattMonitor_MPPT_PacketDigital, hence this should be removed too
2021-12-17 20:24:25 +09:00
Shiv Tyagi
b34a7e46a8
AP_BatteryMonitor: remove AP_BattMonitor_MPPT_PacketDigital class
...
since latest versions of PacketDigital MPPT support UAVCAN, we can remove this older class
2021-12-16 09:39:43 +09:00
Randy Mackay
dea7e969bd
AP_BattMonitor_UAVCAN: re-format text based fault reporting and add get_mavlink_fault_bitmask
2021-12-07 02:12:06 -08:00
Josh Henderson
fb28b39206
AP_BattMonitor: remove old parameter conversion to allow setting BATT_MONITOR to 0
2021-11-16 11:58:01 +11:00
Andrew Tridgell
75dfa6bae4
AP_BattMonitor: support other INA2xx battery monitors
...
added parameters for I2C bus and address. Tested on INA231 and INA226
This allows any 2M flash board to use an INA2xx battery monitor
2021-11-05 14:30:43 +11:00
Iampete1
73fb871695
AP_BatteryMoniter: combine pointer loaded param tables
2021-11-02 11:12:57 +11:00
Randy Mackay
d3c8a5e85f
AP_BattMonitor: add torqeedo battery monitor
2021-10-19 01:30:51 -04:00
李孟晓
bf1a17825c
AP_BattMonitor: Provide the time remaining
2021-10-13 18:44:05 +11:00
Andrew Tridgell
281b8eb234
AP_BattMonitor: support LTC2946 I2C battery monitoring
2021-10-12 15:47:51 +11:00
Andrew Tridgell
2903e10fc0
AP_BattMonitor: added INA231 backend
...
only enabled via hwdef.dat for now
2021-10-12 15:47:51 +11:00
Tatsuya Yamaguchi
1dcc5c3030
AP_BattMonitor: cope with AP_BATT_MONITOR_MAX_INSTANCES < 9
2021-09-22 18:58:12 +10:00
Willian Galvani
735e2ab651
AP_BattMonitor: change capacity_remaining_pct() to a bool
2021-09-08 17:17:41 +10:00
Josh Henderson
289264f1dd
AP_BattMonitor: move analog parameters to subgroupvarptr
2021-08-03 09:36:26 +10:00
Josh Henderson
e37efa45de
AP_BattMonitor: add SMBus address param and create SMBus subtree
2021-08-03 09:36:26 +10:00
Dr.-Ing. Amilcar do Carmo Lucas
85666959ea
AP_BattMonitor: Increase the max. nr. of supported battery cells from 12 to 14
...
Uses a second message, because the original message does not support any more fields
2021-06-15 09:46:26 +10:00
Josh Henderson
80a17cb97f
AP_BattMonitor: get Mavlink charge state
2021-06-08 09:27:13 +10:00
Tom Pittenger
a365e18420
AP_BattMonitor: add MPPT PacketDigital driver
2021-04-28 19:22:53 -07:00
Iampete1
9fdceeded3
AP_BattMoniter: add reset remaining per-instance rename existing to _mask
2021-03-31 19:21:59 +11:00
Patrick José Pereira
d190fff887
AP_BattMonitor: Add missing const in member functions
...
Signed-off-by: Patrick José Pereira <patrickelectric@gmail.com>
2021-02-03 18:45:14 +11:00
Peter Barker
00a8a8fe8e
AP_BattMonitor: use enum class For Battery Failsafe
2020-12-07 15:20:14 +11:00
Tom Pittenger
171a10e117
AP_BattMonitor: Add support for multiple UAVCAN batteries from a single node
2020-11-25 14:20:53 +11:00
Gone4Dirt
836717c0af
AP_BattMonitor: Add support for AP_Generator frontend-backend
2020-11-24 12:54:52 +11:00
Nick Belanger
dbe5b90398
AP_BattMonitor: Adding driver for Rotoye Batmon equipped smart batteries
2020-11-11 14:24:13 +11:00
Peter Barker
2e3ba2a4d2
AP_BattMonitor: move battery type enumeration out of parameters object
2020-08-11 13:21:52 +10:00
Peter Barker
8e708a0a32
AP_BattMonitor: add backend for generator supply
2020-07-03 08:21:42 +09:00
Randy Mackay
3e519b25a4
AP_BattMonitor: fix comments re voltage scaling
2020-06-24 10:19:15 +09:00
Randy Mackay
cc6298e7ac
AP_BattMonitor: SMBus Generic reads up to 12 cell voltages
...
Checks for the highest cell for 15 seconds and then reduces the cell voltage calls to cover only those cells that actually exist
also renames SMBus _last_cell_update_us
2020-06-24 10:19:15 +09:00
Randy Mackay
4ea565e4ed
AP_BattMonitor: Maxell driver inherits from SMBus_Generic
2020-06-05 16:57:39 -07:00
Randy Mackay
f869cd9aa6
AP_BattMonitor: complete rename of SMBus_Maxell to Generic
2020-06-05 16:57:39 -07:00
Randy Mackay
300c0aafb1
AP_BattMonitor: add cycle count for smbus batteries
2019-12-18 15:54:42 +11:00
Andrew Tridgell
fbe69ba9ab
AP_BattMonitor: support selective enable of SMBUS and fuel battery monitors
2019-12-09 21:35:00 +11:00
James
e474b7dcfe
AP_BattMonitor: add PWM Fuel Level Sensor
...
this sensor produces PWM between 1100 and 1900, giving fuel level as a
percentage
2019-08-05 11:35:16 +10:00
Michael du Breuil
0a4e3a77b3
AP_BattMonitor: Refactor interface for fetching current related data
2019-07-14 00:28:00 -07:00