2019-03-12 05:02:29 -03:00
|
|
|
#include <AP_HAL/AP_HAL.h>
|
|
|
|
#include "AP_BattMonitor_FuelFlow.h"
|
|
|
|
#include <GCS_MAVLink/GCS.h>
|
|
|
|
|
|
|
|
/*
|
|
|
|
"battery" monitor for liquid fuel flow systems that give a pulse on
|
|
|
|
a pin for fixed volumes of fuel.
|
|
|
|
|
|
|
|
this driver assumes that BATTx_AMP_PERVLT is set to give the
|
|
|
|
number of millilitres per pulse.
|
|
|
|
|
|
|
|
Output is:
|
|
|
|
|
|
|
|
- current in Amps maps to in litres/hour
|
|
|
|
- consumed mAh is in consumed millilitres
|
|
|
|
- fixed 1.0v voltage
|
|
|
|
*/
|
|
|
|
extern const AP_HAL::HAL& hal;
|
|
|
|
|
|
|
|
#define FUELFLOW_MIN_PULSE_DELTA_US 10
|
|
|
|
|
|
|
|
/// Constructor
|
|
|
|
AP_BattMonitor_FuelFlow::AP_BattMonitor_FuelFlow(AP_BattMonitor &mon,
|
|
|
|
AP_BattMonitor::BattMonitor_State &mon_state,
|
|
|
|
AP_BattMonitor_Params ¶ms) :
|
|
|
|
AP_BattMonitor_Backend(mon, mon_state, params)
|
|
|
|
{
|
|
|
|
_state.voltage = 1.0; // show a fixed voltage of 1v
|
|
|
|
|
|
|
|
// we can't tell if it is healthy as we expect zero pulses when no
|
|
|
|
// fuel is flowing
|
|
|
|
_state.healthy = true;
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
handle interrupt on an instance
|
|
|
|
*/
|
|
|
|
void AP_BattMonitor_FuelFlow::irq_handler(uint8_t pin, bool pin_state, uint32_t timestamp)
|
|
|
|
{
|
|
|
|
if (irq_state.last_pulse_us == 0) {
|
|
|
|
irq_state.last_pulse_us = timestamp;
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
uint32_t delta = timestamp - irq_state.last_pulse_us;
|
|
|
|
if (delta < FUELFLOW_MIN_PULSE_DELTA_US) {
|
|
|
|
// simple de-bounce
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
irq_state.pulse_count++;
|
|
|
|
irq_state.total_us += delta;
|
|
|
|
irq_state.last_pulse_us = timestamp;
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
read - read the "voltage" and "current"
|
|
|
|
*/
|
|
|
|
void AP_BattMonitor_FuelFlow::read()
|
|
|
|
{
|
|
|
|
int8_t pin = _params._curr_pin;
|
|
|
|
if (last_pin != pin) {
|
|
|
|
// detach from last pin
|
|
|
|
if (last_pin != -1) {
|
|
|
|
hal.gpio->detach_interrupt(last_pin);
|
|
|
|
}
|
|
|
|
// attach to new pin
|
|
|
|
last_pin = pin;
|
|
|
|
if (last_pin > 0) {
|
|
|
|
hal.gpio->pinMode(last_pin, HAL_GPIO_INPUT);
|
|
|
|
if (!hal.gpio->attach_interrupt(
|
|
|
|
last_pin,
|
|
|
|
FUNCTOR_BIND_MEMBER(&AP_BattMonitor_FuelFlow::irq_handler, void, uint8_t, bool, uint32_t),
|
|
|
|
AP_HAL::GPIO::INTERRUPT_RISING)) {
|
|
|
|
gcs().send_text(MAV_SEVERITY_WARNING, "FuelFlow: Failed to attach to pin %u", last_pin);
|
|
|
|
}
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
uint32_t now_us = AP_HAL::micros();
|
|
|
|
if (_state.last_time_micros == 0) {
|
|
|
|
// need initial time, so we can work out expected pulse rate
|
|
|
|
_state.last_time_micros = now_us;
|
|
|
|
return;
|
|
|
|
}
|
2019-04-04 19:06:45 -03:00
|
|
|
float dt = (now_us - _state.last_time_micros) * 1.0e-6f;
|
2019-03-12 05:02:29 -03:00
|
|
|
|
|
|
|
if (dt < 1 && irq_state.pulse_count == 0) {
|
|
|
|
// we allow for up to 1 second with no pulses to cope with low
|
|
|
|
// flow idling. After that we will start reading zero current
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
// get the IRQ state with interrupts disabled
|
|
|
|
struct IrqState state;
|
|
|
|
void *irqstate = hal.scheduler->disable_interrupts_save();
|
|
|
|
state = irq_state;
|
|
|
|
irq_state.pulse_count = 0;
|
|
|
|
irq_state.total_us = 0;
|
|
|
|
hal.scheduler->restore_interrupts(irqstate);
|
|
|
|
|
|
|
|
/*
|
|
|
|
this driver assumes that BATTx_AMP_PERVLT is set to give the
|
|
|
|
number of millilitres per pulse.
|
|
|
|
*/
|
2019-04-04 19:06:45 -03:00
|
|
|
float irq_dt = state.total_us * 1.0e-6f;
|
2019-03-12 05:02:29 -03:00
|
|
|
float litres, litres_pec_sec;
|
|
|
|
if (state.pulse_count == 0) {
|
|
|
|
litres = 0;
|
|
|
|
litres_pec_sec = 0;
|
|
|
|
} else {
|
2019-04-04 19:06:45 -03:00
|
|
|
litres = state.pulse_count * _params._curr_amp_per_volt * 0.001f;
|
2019-03-12 05:02:29 -03:00
|
|
|
litres_pec_sec = litres / irq_dt;
|
|
|
|
}
|
|
|
|
|
|
|
|
_state.last_time_micros = now_us;
|
|
|
|
|
|
|
|
// map amps to litres/hour
|
|
|
|
_state.current_amps = litres_pec_sec * (60*60);
|
|
|
|
|
|
|
|
// map consumed_mah to consumed millilitres
|
|
|
|
_state.consumed_mah += litres * 1000;
|
|
|
|
|
|
|
|
// map consumed_wh using fixed voltage of 1
|
|
|
|
_state.consumed_wh = _state.consumed_mah;
|
|
|
|
}
|