Commit Graph

80 Commits

Author SHA1 Message Date
Victor Stinner 978a9afc6a Issue #23243, asyncio: Emit a ResourceWarning when an event loop or a transport
is not explicitly closed. Close also explicitly transports in test_sslproto.
2015-01-29 17:50:58 +01:00
Victor Stinner ff018e406c asyncio: sync with Tulip
* Remove unused SSLProtocol._closing attribute
* test_sslproto: skip test if ssl module is missing
* Python issue #23208: Don't use the traceback of the current handle if we
  already know the traceback of the source. The handle may be more revelant,
  but having 3 tracebacks (handle, source, exception) becomes more difficult to
  read. The handle may be preferred later but it requires more work to make
  this choice.
2015-01-28 00:30:40 +01:00
Victor Stinner 9b524d59b0 Issue #23208, asyncio: Add BaseEventLoop._current_handle
In debug mode, BaseEventLoop._run_once() now sets the
BaseEventLoop._current_handle attribute to the handle currently executed.
In release mode or when no handle is executed, the attribute is None.

BaseEventLoop.default_exception_handler() displays the traceback of the current
handle if available.
2015-01-26 11:05:12 +01:00
Victor Stinner 2596dd0894 asyncio: Close transports on error
Fix create_datagram_endpoint(), connect_read_pipe() and connect_write_pipe():
close the transport if the task is cancelled or on error.
2015-01-26 11:02:18 +01:00
Victor Stinner 0c2e408833 asyncio: BaseEventLoop._create_connection_transport() catchs any exception, not
only Exception
2015-01-22 00:17:41 +01:00
Victor Stinner 442b0adccd asyncio: pyflakes, remove unused import
tests: Remove unused function; inline another function
2015-01-21 23:39:16 +01:00
Victor Stinner 29ad0111bd asyncio: sync with Tulip
* PipeHandle now uses None instead of -1 for a closed handle
* Sort imports in windows_utils.
* Fix test_events on Python older than 3.5. Skip SSL tests on the
  ProactorEventLoop if ssl.MemoryIO is missing
* Fix BaseEventLoop._create_connection_transport(). Close the transport if the
  creation of the transport (if the waiter) gets an exception.
* _ProactorBasePipeTransport now sets _sock to None when the transport is
  closed.
* Fix BaseSubprocessTransport.close(). Ignore pipes for which the protocol is
  not set yet (still equal to None).
* TestLoop.close() now calls the close() method of the parent class
  (BaseEventLoop).
* Cleanup BaseSelectorEventLoop: create the protocol on a separated line for
  readability and ease debugging.
* Fix BaseSubprocessTransport._kill_wait(). Set the _returncode attribute, so
  close() doesn't try to terminate the process.
* Tests: explicitly close event loops and transports
* UNIX pipe transports: add closed/closing in repr(). Add "closed" or "closing"
  state in the __repr__() method of _UnixReadPipeTransport and
  _UnixWritePipeTransport classes.
2015-01-15 00:04:21 +01:00
Victor Stinner 15cc678d89 asyncio: Truncate to 80 columns 2015-01-09 00:09:10 +01:00
Victor Stinner 8d9c145f61 asyncio: _make_ssl_transport: make the waiter parameter optional 2015-01-08 12:06:36 +01:00
Victor Stinner 8c1a4a2326 Issue #23046: Expose the BaseEventLoop class in the asyncio namespace 2015-01-06 01:03:58 +01:00
Victor Stinner 956de691f8 Issue #22926: In debug mode, call_soon(), call_at() and call_later() methods of
asyncio.BaseEventLoop now use the identifier of the current thread to ensure
that they are called from the thread running the event loop.

Before, the get_event_loop() method was used to check the thread, and no
exception was raised when the thread had no event loop. Now the methods always
raise an exception in debug mode when called from the wrong thread. It should
help to notice misusage of the API.
2014-12-26 21:07:52 +01:00
Victor Stinner 3a1c738e6c Issue #23074: asyncio.get_event_loop() now raises an exception if the thread
has no event loop even if assertions are disabled.
2014-12-18 01:20:10 +01:00
Victor Stinner f3e2e09213 Closes #22429, asyncio: Fix EventLoop.run_until_complete(), don't stop the
event loop if a BaseException is raised, because the event loop is already
stopped.
2014-12-05 01:44:10 +01:00
Victor Stinner e80bf0d4a9 Closes #22922: More EventLoop methods fail if the loop is closed. Initial patch
written by Torsten Landschoff.

create_task(), call_at(), call_soon(), call_soon_threadsafe() and
run_in_executor() now raise an error if the event loop is closed.
2014-12-04 23:07:47 +01:00
Victor Stinner 2d99d93d11 asyncio: Coroutine objects are now rejected with a TypeError by the following
functions:

* add_signal_handler()
* call_at()
* call_later()
* call_soon()
* call_soon_threadsafe()
* run_in_executor()

Fix also the error message of add_signal_handler() (fix the name of the
function).
2014-11-20 15:03:52 +01:00
Victor Stinner c8bd53f815 Issue #22601: run_forever() now consumes BaseException of the temporary task
If the coroutine raised a BaseException, consume the exception to not log a
warning. The caller doesn't have access to the local task.
2014-10-11 14:30:18 +02:00
Victor Stinner 68da8fc4c0 Issue #22448: asyncio, cleanup _run_once(), only iterate once to remove delayed
calls that were cancelled.
2014-09-30 18:08:36 +02:00
Yury Selivanov 592ada9b4b asyncio: Improve canceled timer handles cleanup. Closes issue #22448.
Patch by Joshua Moore-Oliva.
2014-09-25 12:07:56 -04:00
Victor Stinner b261475a48 asyncio: sync with Tulip
* PipeServer.close() now cancels the "accept pipe" future which cancels the
  overlapped operation.
* Fix _SelectorTransport.__repr__() if the transport was closed
* Fix debug log in BaseEventLoop.create_connection(): get the socket object
  from the transport because SSL transport closes the old socket and creates a
  new SSL socket object. Remove also the _SelectorSslTransport._rawsock
  attribute: it contained the closed socket (not very useful) and it was not
  used.
* Issue #22063: socket operations (sock_recv, sock_sendall, sock_connect,
  sock_accept) of the proactor event loop don't raise an exception in debug
  mode if the socket are in blocking mode. Overlapped operations also work on
  blocking sockets.
* Fix unit tests in debug mode: mock a non-blocking socket for socket
  operations which now raise an exception if the socket is blocking.
* _fatal_error() method of _UnixReadPipeTransport and _UnixWritePipeTransport
  now log all exceptions in debug mode
* Don't log expected errors in unit tests
* Tulip issue 200: _WaitHandleFuture._unregister_wait() now catchs and logs
  exceptions.
* Tulip issue 200: Log errors in debug mode instead of simply ignoring them.
2014-08-25 23:20:52 +02:00
Victor Stinner 5006b1fd96 Issue #20055: Fix BaseEventLoop.stop() docstring, incomplete sentence.
Patch written by Saimadhav Heblikar.
2014-07-24 11:34:11 +02:00
Victor Stinner acdb782a83 asyncio: sync with Tulip
* Tulip issue #184: Log subprocess events in debug mode

  - Log stdin, stdout and stderr transports and protocols
  - Log process identifier (pid)
  - Log connection of pipes
  - Log process exit
  - Log Process.communicate() tasks: feed stdin, read stdout and stderr
  - Add __repr__() method to many classes related to subprocesses


* Add BaseSubprocessTransport._pid attribute. Store the pid so it is still
  accessible after the process exited. It's more convinient for debug.

* create_connection(): add the socket in the "connected to" debug log

* Clean up some docstrings and comments. Remove unused unimplemented
  _read_from_self().
2014-07-14 18:33:40 +02:00
Victor Stinner e912e652f8 asyncio: sync with Tulip
* Tulip issue #183: log socket events in debug mode

  - Log most important socket events: socket connected, new client, connection
    reset or closed by peer (EOF), etc.
  - Log time elapsed in DNS resolution (getaddrinfo)
  - Log pause/resume reading
  - Log time of SSL handshake
  - Log SSL handshake errors
  - Add a __repr__() method to many classes

* Fix ProactorEventLoop() in debug mode. ProactorEventLoop._make_self_pipe()
  doesn't call call_soon() directly because it checks for the current loop
  which fails, because the method is called to build the event loop.

* Cleanup _ProactorReadPipeTransport constructor. Not need to set again
  _read_fut attribute to None, it is already done in the base class.
2014-07-12 03:11:53 +02:00
Victor Stinner 8ebeb03740 asyncio: improve the documentation of servers
- Fix the documentation of Server.close(): it closes sockets
- Replace AbstractServer with Server
- Document Server.sockets attribute
2014-07-11 23:47:40 +02:00
Victor Stinner b28dbac86d asyncio, Tulip issue 180: Make Server attributes and methods private
- loop, waiters and active_count attributes are now private
- attach(), detach() and wakeup() methods are now private

The sockets attribute remains public.
2014-07-11 22:52:21 +02:00
Victor Stinner 770e48d017 asyncio: sync with Tulip
* Tulip issue #182: Improve logs of BaseEventLoop._run_once()

  - Don't log non-blocking poll
  - Only log polling with a timeout if it gets events or if it timed out after
    more than 1 second.

* Fix some pyflakes warnings: remove unused imports
2014-07-11 11:58:33 +02:00
Victor Stinner c39ba7d611 asyncio: sync with Tulip
- repr(Task) and repr(CoroWrapper) now also includes where these objects were
  created. If the coroutine is not a generator (don't use "yield from"), use
  the location of the function, not the location of the coro() wrapper.
- Fix create_task(): truncate the traceback to hide the call to create_task().
2014-07-11 00:21:27 +02:00
Victor Stinner bfff45d611 asyncion, Tulip issue 181: BaseEventLoop.create_datagram_endpoint() now waits
until protocol.connection_made() has been called. Document also why transport
constructors use a waiter.
2014-07-08 23:57:31 +02:00
Victor Stinner 896a25ab30 asyncio: sync with Tulip
- Tulip issue 185: Add a create_task() method to event loops. The create_task()
  method can be overriden in custom event loop to implement their own task
  class. For example, greenio and Pulsar projects use their own task class. The
  create_task() method is now preferred over creating directly task using the
  Task class.
- tests: fix a warning
- fix typo in the name of a test function
- Update AbstractEventLoop: add new event loop methods; update also the unit test
2014-07-08 11:29:25 +02:00
Victor Stinner 98b6391fd4 Issue #21163: BaseEventLoop.run_until_complete() and test_utils.run_briefly()
don't log the "destroy pending task" message anymore. The log is redundant for
run_until_complete() and useless in run_briefly().
2014-06-30 14:51:04 +02:00
Victor Stinner b75380f333 asyncio: sync with Tulip
- Sort imports
- Simplify/optimize iscoroutine(). Inline inspect.isgenerator(obj): replace it
  with isinstance(obj, types.GeneratorType)
- CoroWrapper: check at runtime if Python has the yield-from bug #21209.  If
  Python has the bug, check if CoroWrapper.send() was called by yield-from to
  decide if parameters must be unpacked or not.
- Fix "Task was destroyed but it is pending!" warning in
  test_task_source_traceback()
2014-06-30 14:39:11 +02:00
Victor Stinner f951d28ac8 asyncio: sync with Tulip, add a new asyncio.coroutines module 2014-06-29 00:46:45 +02:00
Victor Stinner 80f53aa9a0 asyncio, Tulip issue 137: In debug mode, save traceback where Future, Task and
Handle objects are created. Pass the traceback to call_exception_handler() in
the 'source_traceback' key.

The traceback is truncated to hide internal calls in asyncio, show only the
traceback from user code.

Add tests for the new source_traceback, and a test for the 'Future/Task
exception was never retrieved' log.
2014-06-27 13:52:20 +02:00
Victor Stinner 751c7c0f2d asyncio: Fix BaseEventLoop._assert_is_current_event_loop(): get_event_loop()
raises an exception if there is no current loop
2014-06-23 15:14:13 +02:00
Victor Stinner f328c7dc69 asyncio, Tulip issue 171: BaseEventLoop.close() now raises an exception if the
event loop is running. You must first stop the event loop and then wait until
it stopped, before closing it.
2014-06-23 01:02:37 +02:00
Victor Stinner 1580fe3fce asyncio, Tulip issue 172: only log selector timing in debug mode 2014-06-23 00:31:08 +02:00
Victor Stinner 7b7120e159 asyncio: Enable the debug mode of event loops when the PYTHONASYNCIODEBUG
environment variable is set
2014-06-23 00:12:14 +02:00
Victor Stinner d6de5d8455 asyncio: BaseEventLoop._assert_is_current_event_loop() now only raises an
exception if the current loop is not None.

Guido van Rossum wrote:

"The behavior that you can set the loop to None (and keep track of it
explicitly) is part of the spec, and this should still be supported even in
debug mode. The behavior that we raise an error if you are caught having
multiple active loops per thread is just a debugging heuristic, and it
shouldn't break code that follows the spec."
2014-06-23 00:03:43 +02:00
Victor Stinner 0e6f52a211 asyncio, Tulip issue 105: in debug mode, log callbacks taking more than 100 ms
to be executed.
2014-06-20 17:34:15 +02:00
Victor Stinner d143209d7f Tulip issue 83: document more asyncio functions in docstrings 2014-06-19 17:11:49 +02:00
Victor Stinner bb2fc5b2a5 Issue #21326: Add a new is_closed() method to asyncio.BaseEventLoop
Add BaseEventLoop._closed attribute and use it to check if the event loop was
closed or not, instead of checking different attributes in each subclass of
BaseEventLoop.

run_forever() and run_until_complete() methods now raise a RuntimeError('Event loop is
closed') exception if the event loop was closed.

BaseProactorEventLoop.close() now also cancels "accept futures".
2014-06-10 10:23:10 +02:00
Victor Stinner 223a624158 Issue #21119: asyncio now closes sockets on errors
Fix ResourceWarning: create_connection(), create_datagram_endpoint() and
create_unix_server() methods of event loop now close the newly created socket
on error.
2014-06-04 00:11:52 +02:00
Guido van Rossum 3d1bc608a8 asyncio: Upstream issue #167: remove dead code, by Marc Schlaich. 2014-05-10 15:47:15 -07:00
Victor Stinner 93569c2b3d asyncio: Ensure call_soon(), call_later() and call_at() are invoked on current
loop in debug mode. Raise a RuntimeError if the event loop of the current
thread is different.  The check should help to debug thread-safetly issue.
Patch written by David Foster.
2014-03-21 10:00:52 +01:00
Victor Stinner 934c885885 asyncio: _check_resolved_address() must also accept IPv6 without flow_info and
scope_id: (host, port).
2014-02-20 21:59:38 +01:00
Victor Stinner d1a727a9e5 asyncio: Fix _check_resolved_address() for IPv6 address 2014-02-20 16:43:09 +01:00
Victor Stinner 0f3e6bca1b asyncio, Tulip issue #136: Add get/set_debug() methods to BaseEventLoopTests.
Add also a PYTHONASYNCIODEBUG environment variable to debug coroutines since
Python startup, to be able to debug coroutines defined directly in the asyncio
module.
2014-02-19 23:15:02 +01:00
Yury Selivanov 57797521bd asyncio: pep8-ify the code. 2014-02-18 22:56:15 -05:00
Yury Selivanov 569efa2e4b asyncio: New error handling API. Issue #20681. 2014-02-18 18:02:19 -05:00
Yury Selivanov b057c52b01 asyncio: Add support for UNIX Domain Sockets. 2014-02-18 12:15:06 -05:00
Victor Stinner 1b0580b320 ayncio, Tulip issue 129: BaseEventLoop.sock_connect() now raises an error if
the address is not resolved (hostname instead of an IP address) for AF_INET and
AF_INET6 address families.
2014-02-13 09:24:37 +01:00