From 3.8 async functions used with mock.patch return an `AsyncMock`. `_accept_connection2` is an async function where create_task is also mocked. Don't mock `create_task` so that tasks are created out of coroutine returned by `AsyncMock` and the tasks are completed.
https://bugs.python.org/issue37015
*Moved from python/asyncio#493.*
This PR fixes issue python/asyncio#480, as explained in [this comment](https://github.com/python/asyncio/issues/480#issuecomment-278703828).
The `_SelectorDatagramTransport.sendto` method has to be modified ~~so `_sock.sendto` is used in all cases (because it is tricky to reliably tell if the socket is connected or not). Could that be an issue for connected sockets?~~ *EDIT* ... so `_sock.send` is used only if `_sock` is connected.
It also protects `socket.getsockname` against `OSError` in `_SelectorTransport`. This might happen on Windows if the socket is not connected (e.g. for UDP broadcasting).
https://bugs.python.org/issue31922
In this commit:
* Support BufferedProtocol in set_protocol() and start_tls()
* Fix proactor to cancel readers reliably
* Update tests to be compatible with OpenSSL 1.1.1
* Clarify BufferedProtocol docs
* Bump TLS tests timeouts to 60 seconds; eliminate possible race from start_serving
* Rewrite test_start_tls_server_1
* bpo-33263 Fix FD leak in _SelectorSocketTransport. (GH-6450)
Under particular circumstances _SelectorSocketTransport can try to add a reader
even the transport is already being closed. This can lead to FD leak and
invalid stated of the following connections. Fixed the SelectorSocketTransport
to add the reader only if the trasport is still active.
* Remove asyncio.selectors and asyncio._overlapped symbols from the
namespace of the asyncio module
* Replace "from asyncio import selectors" with "import selectors"
* Replace "from asyncio import _overlapped" with "import _overlapped"
asyncio.selectors was added to support Python 3.3, which doesn't have
selectors in its standard library, and Python 3.4 in the same code
base. Same rationale for asyncio._overlapped. Python 3.3 reached its
end of life, and asyncio is no more maintained as a third party
module on PyPI.
* bpo-30280: asyncio now cleans up threads
asyncio base TestCase now uses threading_setup() and
threading_cleanup() of test.support to cleanup threads.
* asyncio: Fix TestBaseSelectorEventLoop cleanup
bpo-30280: TestBaseSelectorEventLoop of
test.test_asyncio.test_selector_events now correctly closes the event
loop: cleanup its executor to not leak threads.
Don't override the close() method of the event loop, only override
the_close_self_pipe() method.
* _SelectorTransport constructor: extra parameter is now optional
* Fix _SelectorDatagramTransport constructor. Only start reading after
connection_made() has been called.
* Fix _SelectorSslTransport.close(). Don't call protocol.connection_lost() if
protocol.connection_made() was not called yet: if the SSL handshake failed or
is still in progress. The close() method can be called if the creation of the
connection is cancelled, by a timeout for example.
* Use test_utils.run_briefly() to execute pending calls to really close
transports
* sslproto: mock also _SSLPipe.shutdown(), it's need to close the transport
* pipe test: the test doesn't close explicitly the PipeHandle, so ignore
the warning instead
* test_popen: use the context manager ("with p:") to explicitly close pipes
* PipeHandle now uses None instead of -1 for a closed handle
* Sort imports in windows_utils.
* Fix test_events on Python older than 3.5. Skip SSL tests on the
ProactorEventLoop if ssl.MemoryIO is missing
* Fix BaseEventLoop._create_connection_transport(). Close the transport if the
creation of the transport (if the waiter) gets an exception.
* _ProactorBasePipeTransport now sets _sock to None when the transport is
closed.
* Fix BaseSubprocessTransport.close(). Ignore pipes for which the protocol is
not set yet (still equal to None).
* TestLoop.close() now calls the close() method of the parent class
(BaseEventLoop).
* Cleanup BaseSelectorEventLoop: create the protocol on a separated line for
readability and ease debugging.
* Fix BaseSubprocessTransport._kill_wait(). Set the _returncode attribute, so
close() doesn't try to terminate the process.
* Tests: explicitly close event loops and transports
* UNIX pipe transports: add closed/closing in repr(). Add "closed" or "closing"
state in the __repr__() method of _UnixReadPipeTransport and
_UnixWritePipeTransport classes.
The new SSL implementation is based on the new ssl.MemoryBIO which is only
available on Python 3.5. On Python 3.4 and older, the legacy SSL implementation
(using SSL_write, SSL_read, etc.) is used. The proactor event loop only
supports the new implementation.
The new asyncio.sslproto module adds _SSLPipe, SSLProtocol and
_SSLProtocolTransport classes. _SSLPipe allows to "wrap" or "unwrap" a socket
(switch between cleartext and SSL/TLS).
Patch written by Antoine Pitrou. sslproto.py is based on gruvi/ssl.py of the
gruvi project written by Geert Jansen.
This change adds SSL support to ProactorEventLoop on Python 3.5 and newer!
It becomes also possible to implement STARTTTLS: switch a cleartext socket to
SSL.
There is a race condition in create_connection() used with wait_for() to have a
timeout. sock_connect() registers the file descriptor of the socket to be
notified of write event (if connect() raises BlockingIOError). When
create_connection() is cancelled with a TimeoutError, sock_connect() coroutine
gets the exception, but it doesn't unregister the file descriptor for write
event. create_connection() gets the TimeoutError and closes the socket.
If you call again create_connection(), the new socket will likely gets the same
file descriptor, which is still registered in the selector. When sock_connect()
calls add_writer(), it tries to modify the entry instead of creating a new one.
This issue was originally reported in the Trollius project, but the bug comes
from Tulip in fact (Trollius is based on Tulip):
https://bitbucket.org/enovance/trollius/issue/15/after-timeouterror-on-wait_for
This change fixes the race condition. It also makes sock_connect() more
reliable (and portable) is sock.connect() raises an InterruptedError.
* PipeServer.close() now cancels the "accept pipe" future which cancels the
overlapped operation.
* Fix _SelectorTransport.__repr__() if the transport was closed
* Fix debug log in BaseEventLoop.create_connection(): get the socket object
from the transport because SSL transport closes the old socket and creates a
new SSL socket object. Remove also the _SelectorSslTransport._rawsock
attribute: it contained the closed socket (not very useful) and it was not
used.
* Issue #22063: socket operations (sock_recv, sock_sendall, sock_connect,
sock_accept) of the proactor event loop don't raise an exception in debug
mode if the socket are in blocking mode. Overlapped operations also work on
blocking sockets.
* Fix unit tests in debug mode: mock a non-blocking socket for socket
operations which now raise an exception if the socket is blocking.
* _fatal_error() method of _UnixReadPipeTransport and _UnixWritePipeTransport
now log all exceptions in debug mode
* Don't log expected errors in unit tests
* Tulip issue 200: _WaitHandleFuture._unregister_wait() now catchs and logs
exceptions.
* Tulip issue 200: Log errors in debug mode instead of simply ignoring them.