Both compileall.compile_dir() and the CLI for compileall now allow for
specifying how many workers to use (or 0 to use all CPUs).
Thanks to Claudiu Popa for the patch.
a package's __init__.py. TestLoader.loadTestsFromModule() still accepts
use_load_tests, but it is deprecated and ignored. A new keyword-only
attribute `pattern` is added and documented. Patch given by Robert Collins,
tweaked by Barry Warsaw.
Optimized bytes and bytes_le properties of UUID and UUID constructor with
bytes_le argument.
Fixed a bug in handling an error occured during reading from a pipe in
_ipconfig_getnode().
threading.Lock.acquire(), threading.RLock.acquire() and socket operations now
use a monotonic clock, instead of the system clock, when a timeout is used.
BaseSelectorEventLoop.sock_connect()
There is a race condition in create_connection() used with wait_for() to have a
timeout. sock_connect() registers the file descriptor of the socket to be
notified of write event (if connect() raises BlockingIOError). When
create_connection() is cancelled with a TimeoutError, sock_connect() coroutine
gets the exception, but it doesn't unregister the file descriptor for write
event. create_connection() gets the TimeoutError and closes the socket.
If you call again create_connection(), the new socket will likely gets the same
file descriptor, which is still registered in the selector. When sock_connect()
calls add_writer(), it tries to modify the entry instead of creating a new one.
This issue was originally reported in the Trollius project, but the bug comes
from Tulip in fact (Trollius is based on Tulip):
https://bitbucket.org/enovance/trollius/issue/15/after-timeouterror-on-wait_for
This change fixes the race condition. It also makes sock_connect() more
reliable (and portable) is sock.connect() raises an InterruptedError.
There is a race condition in create_connection() used with wait_for() to have a
timeout. sock_connect() registers the file descriptor of the socket to be
notified of write event (if connect() raises BlockingIOError). When
create_connection() is cancelled with a TimeoutError, sock_connect() coroutine
gets the exception, but it doesn't unregister the file descriptor for write
event. create_connection() gets the TimeoutError and closes the socket.
If you call again create_connection(), the new socket will likely gets the same
file descriptor, which is still registered in the selector. When sock_connect()
calls add_writer(), it tries to modify the entry instead of creating a new one.
This issue was originally reported in the Trollius project, but the bug comes
from Tulip in fact (Trollius is based on Tulip):
https://bitbucket.org/enovance/trollius/issue/15/after-timeouterror-on-wait_for
This change fixes the race condition. It also makes sock_connect() more
reliable (and portable) is sock.connect() raises an InterruptedError.
Without this reset, starttls would fail if a connect/starttls was done after a
quit, because smtplib assumed the existing value of emspt_features was
accurate, but it gets reset when starttls completes (and the new value does
not contain the starttls capability, since tls is already started at that
point). (There may be additional places where this lack of reset was an
issue as well.)
Patch by Milan Oberkirch.
Don't raise a TimeoutError if we reached the timeout and the future completed
in the same iteration of the event loop. A side effect of the bug is that
Queue.get() looses items.
Don't raise a TimeoutError if we reached the timeout and the future completed
in the same iteration of the event loop. A side effect of the bug is that
Queue.get() looses items.
* PipeServer.close() now cancels the "accept pipe" future which cancels the
overlapped operation.
* Fix _SelectorTransport.__repr__() if the transport was closed
* Fix debug log in BaseEventLoop.create_connection(): get the socket object
from the transport because SSL transport closes the old socket and creates a
new SSL socket object. Remove also the _SelectorSslTransport._rawsock
attribute: it contained the closed socket (not very useful) and it was not
used.
* Issue #22063: socket operations (sock_recv, sock_sendall, sock_connect,
sock_accept) of the proactor event loop don't raise an exception in debug
mode if the socket are in blocking mode. Overlapped operations also work on
blocking sockets.
* Fix unit tests in debug mode: mock a non-blocking socket for socket
operations which now raise an exception if the socket is blocking.
* _fatal_error() method of _UnixReadPipeTransport and _UnixWritePipeTransport
now log all exceptions in debug mode
* Don't log expected errors in unit tests
* Tulip issue 200: _WaitHandleFuture._unregister_wait() now catchs and logs
exceptions.
* Tulip issue 200: Log errors in debug mode instead of simply ignoring them.
* PipeServer.close() now cancels the "accept pipe" future which cancels the
overlapped operation.
* Fix _SelectorTransport.__repr__() if the transport was closed
* Fix debug log in BaseEventLoop.create_connection(): get the socket object
from the transport because SSL transport closes the old socket and creates a
new SSL socket object. Remove also the _SelectorSslTransport._rawsock
attribute: it contained the closed socket (not very useful) and it was not
used.
* Issue #22063: socket operations (sock_recv, sock_sendall, sock_connect,
sock_accept) of the proactor event loop don't raise an exception in debug
mode if the socket are in blocking mode. Overlapped operations also work on
blocking sockets.
* Fix unit tests in debug mode: mock a non-blocking socket for socket
operations which now raise an exception if the socket is blocking.
* _fatal_error() method of _UnixReadPipeTransport and _UnixWritePipeTransport
now log all exceptions in debug mode
* Don't log expected errors in unit tests
* Tulip issue 200: _WaitHandleFuture._unregister_wait() now catchs and logs
exceptions.
* Tulip issue 200: Log errors in debug mode instead of simply ignoring them.
window is created for every test class.
Fixed Tkinter images copying operations in NoDefaultRoot mode.
Tcl command names generated for "after" callbacks now contains a name of
original function.
window is created for every test class.
Fixed Tkinter images copying operations in NoDefaultRoot mode.
Tcl command names generated for "after" callbacks now contains a name of
original function.
Patch by Milan Oberkirch, developed as part of his 2014 GSOC project.
Note that this also fixes a bug in mock_socket ('getpeername' was returning a
simple string instead of the tuple required for IPvX protocols), a bug in
DebugServer with respect to handling binary data (should have been fixed when
decode_data was introduced, but wasn't found until this patch was written),
and a long-standing bug in DebugServer (it was printing an extra blank line at
the end of the displayed message text).
`mkdir -p` and `os.makedirs()` functionality. When true, ignore
FileExistsErrors. Patch by Berker Peksag.
(With minor cleanups, additional tests, doc tweaks, etc. by Barry)
Also:
* Remove some unused imports in test_pathlib.py reported by pyflakes.
- Close#22063: socket operations (socket,recv, sock_sendall, sock_connect,
sock_accept) now raise an exception in debug mode if sockets are in blocking
mode.
- asyncio: Use the new os.set_blocking() function of Python 3.5 if available
* _WaitHandleFuture.cancel() now notify IocpProactor through the overlapped
object that the wait was cancelled.
* Optimize IocpProactor.wait_for_handle() gets the result if the wait is
signaled immediatly.
* Enhance representation of Future and Future subclasses
- Add "created at filename:lineno" in the representation
- Add Future._repr_info() method which can be more easily overriden than
Future.__repr__(). It should now be more easy to enhance Future
representation without having to modify each subclass. For example,
_OverlappedFuture and _WaitHandleFuture get the new "created at" information.
- Use reprlib to format Future result, and function arguments when formatting a
callback, to limit the length of the representation.
* Fix repr(_WaitHandleFuture)
* _WaitHandleFuture and _OverlappedFuture: hide frames of internal calls in the
source traceback.
* Cleanup ProactorIocp._poll(): set the timeout to 0 after the first call to
GetQueuedCompletionStatus()
* test_locks: close the temporary event loop and check the condition lock
* Remove workaround in test_futures, no more needed
* _WaitHandleFuture.cancel() now notify IocpProactor through the overlapped
object that the wait was cancelled.
* Optimize IocpProactor.wait_for_handle() gets the result if the wait is
signaled immediatly.
* Enhance representation of Future and Future subclasses
- Add "created at filename:lineno" in the representation
- Add Future._repr_info() method which can be more easily overriden than
Future.__repr__(). It should now be more easy to enhance Future
representation without having to modify each subclass. For example,
_OverlappedFuture and _WaitHandleFuture get the new "created at" information.
- Use reprlib to format Future result, and function arguments when formatting a
callback, to limit the length of the representation.
* Fix repr(_WaitHandleFuture)
* _WaitHandleFuture and _OverlappedFuture: hide frames of internal calls in the
source traceback.
* Cleanup ProactorIocp._poll(): set the timeout to 0 after the first call to
GetQueuedCompletionStatus()
* test_locks: close the temporary event loop and check the condition lock
* Remove workaround in test_futures, no more needed
the overlapped in the _cache dictionary, even if we already got the result. We
need to keep a reference to the overlapped object, otherwise the memory may be
reused and GetQueuedCompletionStatus() may use random bytes and behaves badly.
There is still a hack for ConnectNamedPipe(): the overlapped object is not
register into _cache if the overlapped object completed directly.
Log also an error in debug mode in ProactorIocp._loop() if we get an unexpected
event.
Add a protection in ProactorIocp.close() to avoid blocking, even if it should
not happen. I still don't understand exactly why some the completion of some
overlapped objects are not notified.
in the _cache dictionary, even if we already got the result. We need to keep a
reference to the overlapped object, otherwise the memory may be reused and
GetQueuedCompletionStatus() may use random bytes and behaves badly.
There is still a hack for ConnectNamedPipe(): the overlapped object is not
register into _cache if the overlapped object completed directly.
Log also an error in debug mode in ProactorIocp._loop() if we get an unexpected
event.
Add a protection in ProactorIocp.close() to avoid blocking, even if it should
not happen. I still don't understand exactly why some the completion of some
overlapped objects are not notified.
2009-02-02 51562 (27c589f09a21) merged Mac support revisions into 3.0.
2009-03-04 52014 (dc3d24824b60) merged slightly improved version into 2.7.
Change 3.4+ to match the later 2.7 patch. Buttons tested manually.
reference to the overlapped object. IocpProactor._poll() now also ignores false
alarms: GetQueuedCompletionStatus() returns the overlapped but it is still
pending.
* Tulip issue #196: IocpProactor._poll() clears the reference to the
overlapped operation when the operation is done. It would be better to clear
the reference in a new _OverlappedFuture.set_result() method, but it cannot
be done yet because of a weird bug.
* BaseSelectorEventLoop._write_to_self() now logs errors in debug mode.
* Tulip issue #196: IocpProactor._poll() clears the reference to the
overlapped operation when the operation is done. It would be better to clear
the reference in a new _OverlappedFuture.set_result() method, but it cannot
be done yet because of a weird bug.
* BaseSelectorEventLoop._write_to_self() now logs errors in debug mode.
* Fix _WaitHandleFuture.cancel(): return the result of the parent cancel()
method.
* _OverlappedFuture.cancel() now clears its reference to the overlapped object.
Make also the _OverlappedFuture.ov attribute private.
* Check if _WaitHandleFuture completed before unregistering it in the callback.
Add also _WaitHandleFuture._poll() and repr(_WaitHandleFuture).
* _WaitHandleFuture now unregisters its wait handler if WaitForSingleObject()
raises an exception.
* _OverlappedFuture.set_exception() now cancels the overlapped operation.
* Fix _WaitHandleFuture.cancel(): return the result of the parent cancel()
method.
* _OverlappedFuture.cancel() now clears its reference to the overlapped object.
Make also the _OverlappedFuture.ov attribute private.
* Check if _WaitHandleFuture completed before unregistering it in the callback.
Add also _WaitHandleFuture._poll() and repr(_WaitHandleFuture).
* _WaitHandleFuture now unregisters its wait handler if WaitForSingleObject()
raises an exception.
* _OverlappedFuture.set_exception() now cancels the overlapped operation.
Improve stability of the proactor event loop, especially operations on
overlapped objects:
* Tulip issue 195: Don't call UnregisterWait() twice if a _WaitHandleFuture is
cancelled twice to fix a crash.
* IocpProactor.close(): cancel futures to cancel overlapped operations, instead
of cancelling directly overlapped operations. Future objects may not call
ov.cancel() if the future was cancelled or if the overlapped was already
cancelled. The cancel() method of the future may also catch exceptions. Log
also errors on cancellation.
* tests: rename "f" to "fut"
* Add a __repr__() method to IocpProactor
* Add a destructor to IocpProactor which closes it
* _OverlappedFuture.cancel() doesn't cancel the overlapped anymore if it is
done: if it is already cancelled or completed. Log also an error if the
cancellation failed.
* Add the address of the overlapped object in repr(_OverlappedFuture)
* _OverlappedFuture truncates the source traceback to hide the call to the
parent constructor (useless in debug).
Improve stability of the proactor event loop, especially operations on
overlapped objects:
* Tulip issue 195: Don't call UnregisterWait() twice if a _WaitHandleFuture is
cancelled twice to fix a crash.
* IocpProactor.close(): cancel futures to cancel overlapped operations, instead
of cancelling directly overlapped operations. Future objects may not call
ov.cancel() if the future was cancelled or if the overlapped was already
cancelled. The cancel() method of the future may also catch exceptions. Log
also errors on cancellation.
* tests: rename "f" to "fut"
* Add a __repr__() method to IocpProactor
* Add a destructor to IocpProactor which closes it
* _OverlappedFuture.cancel() doesn't cancel the overlapped anymore if it is
done: if it is already cancelled or completed. Log also an error if the
cancellation failed.
* Add the address of the overlapped object in repr(_OverlappedFuture)
* _OverlappedFuture truncates the source traceback to hide the call to the
parent constructor (useless in debug).
ignores BlockingIOError exceptions. Initial patch written by Xavier de Gaye.
Document also in asyncore documentation that recv() may raise BlockingIOError.
not a terminal to not write the ANSI sequence "\033[1034h" into stdout. This
sequence is used on some terminal (ex: TERM=xterm-256color") to enable support
of 8 bit characters.
terminal to not write the ANSI sequence "\033[1034h" into stdout. This sequence
is used on some terminal (ex: TERM=xterm-256color") to enable support of 8 bit
characters.
lines or narrowed for small screens.
Issie #19132: Turtledemo buttons no longer disappear when window is shrun.
Patch mostly by Lita Cho (21597) using idea from patch by Jan Kanis (18132).
Adds `load_package_tests` function to test.support, uses it in test_asyncio,
test_email, test_json, test_tools, test_importlib and all test_importlib
sub-packages to implement test discovery.
* Issue #19811, #22022: test_pathlib uses support.rmtree() instead of
shutil.rmtree() to remove the temporary directory.
* Issue #19629: Fix support.rmtree(), use os.lstat() to check if the file is a
directory, not os.path.isdir()
- Use _testcapi.raise_signal() in test_signal
- close also os.pipe() file descriptors in some test_signal tests where they
were not closed properly
- Remove faulthandler._sigill() and faulthandler._sigbus(): reuse
_testcapi.raise_signal() in test_faulthandler
Since Python 3.3, the C signal handler writes the signal number into the wakeup
file descriptor and then schedules the Python call using Py_AddPendingCall().
asyncio uses the wakeup file descriptor to wake up the event loop, and relies
on Py_AddPendingCall() to schedule the final callback with call_soon().
If the C signal handler is called in a thread different than the thread of the
event loop, the loop is awaken but Py_AddPendingCall() was not called yet. In
this case, the event loop has nothing to do and go to sleep again.
Py_AddPendingCall() is called while the event loop is sleeping again and so the
final callback is not scheduled immediatly.
This patch changes how asyncio handles signals. Instead of relying on
Py_AddPendingCall() and the wakeup file descriptor, asyncio now only relies on
the wakeup file descriptor. asyncio reads signal numbers from the wakeup file
descriptor to call its signal handler.
Since Python 3.3, the C signal handler writes the signal number into the wakeup
file descriptor and then schedules the Python call using Py_AddPendingCall().
asyncio uses the wakeup file descriptor to wake up the event loop, and relies
on Py_AddPendingCall() to schedule the final callback with call_soon().
If the C signal handler is called in a thread different than the thread of the
event loop, the loop is awaken but Py_AddPendingCall() was not called yet. In
this case, the event loop has nothing to do and go to sleep again.
Py_AddPendingCall() is called while the event loop is sleeping again and so the
final callback is not scheduled immediatly.
This patch changes how asyncio handles signals. Instead of relying on
Py_AddPendingCall() and the wakeup file descriptor, asyncio now only relies on
the wakeup file descriptor. asyncio reads signal numbers from the wakeup file
descriptor to call its signal handler.
BrokenPipeError
If you want to handle the BrokenPipeError, you can easily reimplement
communicate().
Add also a unit test to ensure that stdin.write() + stdin.drain() raises
BrokenPipeError.
If you want to handle the BrokenPipeError, you can easily reimplement
communicate().
Add also a unit test to ensure that stdin.write() + stdin.drain() raises
BrokenPipeError.
* Tulip issue #184: Log subprocess events in debug mode
- Log stdin, stdout and stderr transports and protocols
- Log process identifier (pid)
- Log connection of pipes
- Log process exit
- Log Process.communicate() tasks: feed stdin, read stdout and stderr
- Add __repr__() method to many classes related to subprocesses
* Add BaseSubprocessTransport._pid attribute. Store the pid so it is still
accessible after the process exited. It's more convinient for debug.
* create_connection(): add the socket in the "connected to" debug log
* Clean up some docstrings and comments. Remove unused unimplemented
_read_from_self().
* Tulip issue #183: log socket events in debug mode
- Log most important socket events: socket connected, new client, connection
reset or closed by peer (EOF), etc.
- Log time elapsed in DNS resolution (getaddrinfo)
- Log pause/resume reading
- Log time of SSL handshake
- Log SSL handshake errors
- Add a __repr__() method to many classes
* Fix ProactorEventLoop() in debug mode. ProactorEventLoop._make_self_pipe()
doesn't call call_soon() directly because it checks for the current loop
which fails, because the method is called to build the event loop.
* Cleanup _ProactorReadPipeTransport constructor. Not need to set again
_read_fut attribute to None, it is already done in the base class.
- loop, waiters and active_count attributes are now private
- attach(), detach() and wakeup() methods are now private
The sockets attribute remains public.
:c:type:`int` for the size to support reading more than 2 GB at once. On
Windows, the size is truncted to INT_MAX. As any call to os.read(), the OS
may read less bytes than the number of requested bytes.
* Tulip issue #182: Improve logs of BaseEventLoop._run_once()
- Don't log non-blocking poll
- Only log polling with a timeout if it gets events or if it timed out after
more than 1 second.
* Fix some pyflakes warnings: remove unused imports
* Tulip issue #182: Improve logs of BaseEventLoop._run_once()
- Don't log non-blocking poll
- Only log polling with a timeout if it gets events or if it timed out after
more than 1 second.
* Fix some pyflakes warnings: remove unused imports
- CoroWrapper.__del__() now reuses repr(CoroWrapper) to log the "... was never
yielded from" warning
- Improve CoroWrapper: copy also the qualified name on Python 3.4, not only on
Python 3.5+
- CoroWrapper.__del__() now reuses repr(CoroWrapper) to log the "... was never
yielded from" warning
- Improve CoroWrapper: copy also the qualified name on Python 3.4, not only on
Python 3.5+
- repr(Task) and repr(CoroWrapper) now also includes where these objects were
created. If the coroutine is not a generator (don't use "yield from"), use
the location of the function, not the location of the coro() wrapper.
- Fix create_task(): truncate the traceback to hide the call to create_task().
- repr(Task) and repr(CoroWrapper) now also includes where these objects were
created. If the coroutine is not a generator (don't use "yield from"), use
the location of the function, not the location of the coro() wrapper.
- Fix create_task(): truncate the traceback to hide the call to create_task().
- Issues #21936, #21163: Fix sporadic failures of
test_future_exception_never_retrieved()
- Handle.cancel() now clears references to callback and args
- In debug mode, repr(Handle) now contains the location where the Handle was
created.
- Issues #21936, #21163: Fix sporadic failures of
test_future_exception_never_retrieved()
- Handle.cancel() now clears references to callback and args
- In debug mode, repr(Handle) now contains the location where the Handle was
created.
asyncio: sync with Tulip
- Tulip issue 185: Add a create_task() method to event loops. The create_task()
method can be overriden in custom event loop to implement their own task
class. For example, greenio and Pulsar projects use their own task class. The
create_task() method is now preferred over creating directly task using the
Task class.
- tests: fix a warning
- fix typo in the name of a test function
- Update AbstractEventLoop: add new event loop methods; update also the unit test
Update asyncio documentation
- Document the new create_task() method
- "Hide" the Task class: point to the create_task() method for interoperability
- Rewrite the documentation of the Task class
- Document the "Pending task destroyed"
- Update output in debug mode of examples in the dev section
- Replace Task() with create_task() in examples
- Tulip issue 185: Add a create_task() method to event loops. The create_task()
method can be overriden in custom event loop to implement their own task
class. For example, greenio and Pulsar projects use their own task class. The
create_task() method is now preferred over creating directly task using the
Task class.
- tests: fix a warning
- fix typo in the name of a test function
- Update AbstractEventLoop: add new event loop methods; update also the unit test
- Tulip issue #181: Faster create_connection(). Call directly
waiter.set_result() in the constructor of _ProactorBasePipeTransport and
_SelectorSocketTransport, instead of using of delaying the call with
call_soon().
- Cleanup iscoroutine()
- Tulip issue #181: Faster create_connection(). Call directly
waiter.set_result() in the constructor of _ProactorBasePipeTransport and
_SelectorSocketTransport, instead of using of delaying the call with
call_soon().
- Cleanup iscoroutine()