Issue #26604:
* Add a new optional source parameter to _warnings.warn() and warnings.warn()
* Modify asyncore, asyncio and _pyio modules to set the source parameter when
logging a ResourceWarning warning
Issue #23347: send_signal(), kill() and terminate() methods of
BaseSubprocessTransport now check if the transport was closed and if the
process exited.
Issue #23347: Refactor creation of subprocess transports. Changes on
BaseSubprocessTransport:
* Add a wait() method to wait until the child process exit
* The constructor now accepts an optional waiter parameter. The _post_init()
coroutine must not be called explicitly anymore. It makes subprocess
transports closer to other transports, and it gives more freedom if we want
later to change completly how subprocess transports are created.
* close() now kills the process instead of kindly terminate it: the child
process may ignore SIGTERM and continue to run. Call explicitly terminate()
and wait() if you want to kindly terminate the child process.
* close() now logs a warning in debug mode if the process is still running and
needs to be killed
* _make_subprocess_transport() is now fully asynchronous again: if the creation
of the transport failed, wait asynchronously for the process eixt. Before the
wait was synchronous. This change requires close() to *kill*, and not
terminate, the child process.
* Remove the _kill_wait() method, replaced with a more agressive close()
method. It fixes _make_subprocess_transport() on error.
BaseSubprocessTransport.close() calls the close() method of pipe transports,
whereas _kill_wait() closed directly pipes of the subprocess.Popen object
without unregistering file descriptors from the selector (which caused severe
bugs).
These changes simplifies the code of subprocess.py.
* Cleanup gather(): use cancelled() method instead of using private Future
attribute
* Fix _UnixReadPipeTransport and _UnixWritePipeTransport. Only start reading
when connection_made() has been called.
* Issue #23333: Fix BaseSelectorEventLoop._accept_connection(). Close the
transport on error. In debug mode, log errors using call_exception_handler()
* Rephrase also the comment explaining why the waiter is not awaken immediatly.
* SSLProtocol.eof_received() doesn't instanciate ConnectionResetError exception
directly, it will be done by Future.set_exception(). The exception is not
used if the waiter was cancelled or if there is no waiter.
* PipeHandle now uses None instead of -1 for a closed handle
* Sort imports in windows_utils.
* Fix test_events on Python older than 3.5. Skip SSL tests on the
ProactorEventLoop if ssl.MemoryIO is missing
* Fix BaseEventLoop._create_connection_transport(). Close the transport if the
creation of the transport (if the waiter) gets an exception.
* _ProactorBasePipeTransport now sets _sock to None when the transport is
closed.
* Fix BaseSubprocessTransport.close(). Ignore pipes for which the protocol is
not set yet (still equal to None).
* TestLoop.close() now calls the close() method of the parent class
(BaseEventLoop).
* Cleanup BaseSelectorEventLoop: create the protocol on a separated line for
readability and ease debugging.
* Fix BaseSubprocessTransport._kill_wait(). Set the _returncode attribute, so
close() doesn't try to terminate the process.
* Tests: explicitly close event loops and transports
* UNIX pipe transports: add closed/closing in repr(). Add "closed" or "closing"
state in the __repr__() method of _UnixReadPipeTransport and
_UnixWritePipeTransport classes.
* Tulip issue 184: FlowControlMixin constructor now get the event loop if the
loop parameter is not set. Add unit tests to ensure that constructor of
StreamReader and StreamReaderProtocol classes get the event loop.
* Remove outdated TODO/XXX
written by Torsten Landschoff.
create_task(), call_at(), call_soon(), call_soon_threadsafe() and
run_in_executor() now raise an error if the event loop is closed.
functions:
* add_signal_handler()
* call_at()
* call_later()
* call_soon()
* call_soon_threadsafe()
* run_in_executor()
Fix also the error message of add_signal_handler() (fix the name of the
function).
Move the _loop attribute from the constructor of _SelectorTransport,
_ProactorBasePipeTransport and _UnixWritePipeTransport classes to the
constructor of the _FlowControlMixin class.
Add also an assertion to explicit that the parent class must ensure that the
loop is defined (not None)