Fix typo from commit 6370f345e1
Signed-off-by: Christian Heimes <christian@python.org>
<!--
Thanks for your contribution!
Please read this comment in its entirety. It's quite important.
# Pull Request title
It should be in the following format:
```
bpo-NNNN: Summary of the changes made
```
Where: bpo-NNNN refers to the issue number in the https://bugs.python.org.
Most PRs will require an issue number. Trivial changes, like fixing a typo, do not need an issue.
# Backport Pull Request title
If this is a backport PR (PR made against branches other than `master`),
please ensure that the PR title is in the following format:
```
[X.Y] <title from the original PR> (GH-NNNN)
```
Where: [X.Y] is the branch name, e.g. [3.6].
GH-NNNN refers to the PR number from `master`.
-->
<!-- issue-number: bpo-32262 -->
https://bugs.python.org/issue32262
<!-- /issue-number -->
* Convert asyncio/tasks.py to async/await
* Convert asyncio/queues.py to async/await
* Convert asyncio/test_utils.py to async/await
* Convert asyncio/base_subprocess.py to async/await
* Convert asyncio/subprocess.py to async/await
* Convert asyncio/streams.py to async/await
* Fix comments
* Convert asyncio/locks.py to async/await
* Convert asyncio.sleep to async def
* Add a comment
* Add missing news
* Convert stubs from AbstrctEventLoop to async functions
* Convert subprocess_shell/subprocess_exec
* Convert connect_read_pipe/connect_write_pip to async/await syntax
* Convert create_datagram_endpoint
* Convert create_unix_server/create_unix_connection
* Get rid of old style coroutines in unix_events.py
* Convert selector_events.py to async/await
* Convert wait_closed and create_connection
* Drop redundant line
* Convert base_events.py
* Code cleanup
* Drop redundant comments
* Fix indentation
* Add explicit tests for compatibility between old and new coroutines
* Convert windows event loop to use async/await
* Fix double awaiting of async function
* Convert asyncio/locks.py
* Improve docstring
* Convert tests to async/await
* Convert more tests
* Convert more tests
* Convert more tests
* Convert tests
* Improve test
* bpo-31034: Reliable signal handler for test_asyncio
Don't rely on the current SIGHUP signal handler, make sure that it's
set to the "default" signal handler: SIG_DFL.
* Add comments
Issue #24763: Fix resource warnings when asyncio.BaseSubprocessTransport
constructor fails, if subprocess.Popen raises an exception for example.
Patch written by Martin Richard, test written by me.
transport was closed. The check broken a Tulip example and this limitation is
arbitrary. Check if _proc is None should be enough.
Enhance also close(): do nothing when called the second time.
Issue #23347: send_signal(), kill() and terminate() methods of
BaseSubprocessTransport now check if the transport was closed and if the
process exited.
Issue #23347: Refactor creation of subprocess transports. Changes on
BaseSubprocessTransport:
* Add a wait() method to wait until the child process exit
* The constructor now accepts an optional waiter parameter. The _post_init()
coroutine must not be called explicitly anymore. It makes subprocess
transports closer to other transports, and it gives more freedom if we want
later to change completly how subprocess transports are created.
* close() now kills the process instead of kindly terminate it: the child
process may ignore SIGTERM and continue to run. Call explicitly terminate()
and wait() if you want to kindly terminate the child process.
* close() now logs a warning in debug mode if the process is still running and
needs to be killed
* _make_subprocess_transport() is now fully asynchronous again: if the creation
of the transport failed, wait asynchronously for the process eixt. Before the
wait was synchronous. This change requires close() to *kill*, and not
terminate, the child process.
* Remove the _kill_wait() method, replaced with a more agressive close()
method. It fixes _make_subprocess_transport() on error.
BaseSubprocessTransport.close() calls the close() method of pipe transports,
whereas _kill_wait() closed directly pipes of the subprocess.Popen object
without unregistering file descriptors from the selector (which caused severe
bugs).
These changes simplifies the code of subprocess.py.
Override the connect_read_pipe() method of the loop to mock immediatly
pause_reading() and resume_reading() methods.
The test failed randomly on FreeBSD 9 buildbot and on Windows using trollius.
* Use test_utils.run_briefly() to execute pending calls to really close
transports
* sslproto: mock also _SSLPipe.shutdown(), it's need to close the transport
* pipe test: the test doesn't close explicitly the PipeHandle, so ignore
the warning instead
* test_popen: use the context manager ("with p:") to explicitly close pipes
* If an exception is raised during the creation of a subprocess, kill the
subprocess (close pipes, kill and read the return status). Log an error in
such case.
* Fix SubprocessStreamProtocol.connection_made() to handle cancelled waiter.
Add unit test cancelling subprocess methods.