bpo-31034: Reliable signal handler for test_asyncio (#2867)
* bpo-31034: Reliable signal handler for test_asyncio Don't rely on the current SIGHUP signal handler, make sure that it's set to the "default" signal handler: SIG_DFL. * Add comments
This commit is contained in:
parent
302bbbe9ba
commit
830080913c
|
@ -1980,6 +1980,11 @@ class SubprocessTestsMixin:
|
||||||
|
|
||||||
@unittest.skipIf(sys.platform == 'win32', "Don't have SIGHUP")
|
@unittest.skipIf(sys.platform == 'win32', "Don't have SIGHUP")
|
||||||
def test_subprocess_send_signal(self):
|
def test_subprocess_send_signal(self):
|
||||||
|
# bpo-31034: Make sure that we get the default signal handler (killing
|
||||||
|
# the process). The parent process may have decided to ignore SIGHUP,
|
||||||
|
# and signal handlers are inherited.
|
||||||
|
old_handler = signal.signal(signal.SIGHUP, signal.SIG_DFL)
|
||||||
|
try:
|
||||||
prog = os.path.join(os.path.dirname(__file__), 'echo.py')
|
prog = os.path.join(os.path.dirname(__file__), 'echo.py')
|
||||||
|
|
||||||
connect = self.loop.subprocess_exec(
|
connect = self.loop.subprocess_exec(
|
||||||
|
@ -1993,6 +1998,8 @@ class SubprocessTestsMixin:
|
||||||
self.loop.run_until_complete(proto.completed)
|
self.loop.run_until_complete(proto.completed)
|
||||||
self.assertEqual(-signal.SIGHUP, proto.returncode)
|
self.assertEqual(-signal.SIGHUP, proto.returncode)
|
||||||
transp.close()
|
transp.close()
|
||||||
|
finally:
|
||||||
|
signal.signal(signal.SIGHUP, old_handler)
|
||||||
|
|
||||||
def test_subprocess_stderr(self):
|
def test_subprocess_stderr(self):
|
||||||
prog = os.path.join(os.path.dirname(__file__), 'echo2.py')
|
prog = os.path.join(os.path.dirname(__file__), 'echo2.py')
|
||||||
|
|
|
@ -166,6 +166,11 @@ class SubprocessMixin:
|
||||||
|
|
||||||
@unittest.skipIf(sys.platform == 'win32', "Don't have SIGHUP")
|
@unittest.skipIf(sys.platform == 'win32', "Don't have SIGHUP")
|
||||||
def test_send_signal(self):
|
def test_send_signal(self):
|
||||||
|
# bpo-31034: Make sure that we get the default signal handler (killing
|
||||||
|
# the process). The parent process may have decided to ignore SIGHUP,
|
||||||
|
# and signal handlers are inherited.
|
||||||
|
old_handler = signal.signal(signal.SIGHUP, signal.SIG_DFL)
|
||||||
|
try:
|
||||||
code = 'import time; print("sleeping", flush=True); time.sleep(3600)'
|
code = 'import time; print("sleeping", flush=True); time.sleep(3600)'
|
||||||
args = [sys.executable, '-c', code]
|
args = [sys.executable, '-c', code]
|
||||||
create = asyncio.create_subprocess_exec(*args,
|
create = asyncio.create_subprocess_exec(*args,
|
||||||
|
@ -185,6 +190,8 @@ class SubprocessMixin:
|
||||||
|
|
||||||
returncode = self.loop.run_until_complete(send_signal(proc))
|
returncode = self.loop.run_until_complete(send_signal(proc))
|
||||||
self.assertEqual(-signal.SIGHUP, returncode)
|
self.assertEqual(-signal.SIGHUP, returncode)
|
||||||
|
finally:
|
||||||
|
signal.signal(signal.SIGHUP, old_handler)
|
||||||
|
|
||||||
def prepare_broken_pipe_test(self):
|
def prepare_broken_pipe_test(self):
|
||||||
# buffer large enough to feed the whole pipe buffer
|
# buffer large enough to feed the whole pipe buffer
|
||||||
|
|
Loading…
Reference in New Issue