1998-08-10 16:42:37 -03:00
|
|
|
\section{\module{code} ---
|
2000-04-03 17:13:55 -03:00
|
|
|
Interpreter base classes}
|
1998-07-23 14:59:49 -03:00
|
|
|
\declaremodule{standard}{code}
|
|
|
|
|
2000-04-03 17:13:55 -03:00
|
|
|
\modulesynopsis{Base classes for interactive Python interpreters.}
|
1998-07-23 14:59:49 -03:00
|
|
|
|
1997-07-18 18:08:07 -03:00
|
|
|
|
2000-04-03 17:13:55 -03:00
|
|
|
The \code{code} module provides facilities to implement
|
|
|
|
read-eval-print loops in Python. Two classes and convenience
|
|
|
|
functions are included which can be used to build applications which
|
|
|
|
provide an interactive interpreter prompt.
|
1997-07-18 18:08:07 -03:00
|
|
|
|
|
|
|
|
2000-04-03 17:13:55 -03:00
|
|
|
\begin{classdesc}{InteractiveInterpreter}{\optional{locals}}
|
|
|
|
This class deals with parsing and interpreter state (the user's
|
|
|
|
namespace); it does not deal with input buffering or prompting or
|
|
|
|
input file naming (the filename is always passed in explicitly).
|
|
|
|
The optional \var{locals} argument specifies the dictionary in
|
|
|
|
which code will be executed; it defaults to a newly created
|
|
|
|
dictionary with key \code{'__name__'} set to \code{'__console__'}
|
|
|
|
and key \code{'__doc__'} set to \code{None}.
|
|
|
|
\end{classdesc}
|
|
|
|
|
|
|
|
\begin{classdesc}{InteractiveConsole}{\optional{locals\optional{, filename}}}
|
|
|
|
Closely emulate the behavior of the interactive Python interpreter.
|
|
|
|
This class builds on \class{InteractiveInterpreter} and adds
|
|
|
|
prompting using the familiar \code{sys.ps1} and \code{sys.ps2}, and
|
|
|
|
input buffering.
|
|
|
|
\end{classdesc}
|
|
|
|
|
|
|
|
|
|
|
|
\begin{funcdesc}{interact}{\optional{banner\optional{,
|
|
|
|
readfunc\optional{, local}}}}
|
|
|
|
Convenience function to run a read-eval-print loop. This creates a
|
|
|
|
new instance of \class{InteractiveConsole} and sets \var{readfunc}
|
|
|
|
to be used as the \method{raw_input()} method, if provided. If
|
|
|
|
\var{local} is provided, it is passed to the
|
|
|
|
\class{InteractiveConsole} constructor for use as the default
|
|
|
|
namespace for the interpreter loop. The \method{interact()} method
|
|
|
|
of the instance is then run with \var{banner} passed as the banner
|
|
|
|
to use, if provided. The console object is discarded after use.
|
|
|
|
\end{funcdesc}
|
|
|
|
|
|
|
|
\begin{funcdesc}{compile_command}{source\optional{,
|
|
|
|
filename\optional{, symbol}}}
|
1997-07-18 18:08:07 -03:00
|
|
|
This function is useful for programs that want to emulate Python's
|
|
|
|
interpreter main loop (a.k.a. the read-eval-print loop). The tricky
|
|
|
|
part is to determine when the user has entered an incomplete command
|
2000-04-03 17:13:55 -03:00
|
|
|
that can be completed by entering more text (as opposed to a
|
|
|
|
complete command or a syntax error). This function
|
|
|
|
\emph{almost} always makes the same decision as the real interpreter
|
|
|
|
main loop.
|
|
|
|
|
|
|
|
\var{source} is the source string; \var{filename} is the optional
|
|
|
|
filename from which source was read, defaulting to \code{'<input>'};
|
|
|
|
and \var{symbol} is the optional grammar start symbol, which should
|
|
|
|
be either \code{'single'} (the default) or \code{'eval'}.
|
|
|
|
|
|
|
|
Returns a code object (the same as \code{compile(\var{source},
|
|
|
|
\var{filename}, \var{symbol})}) if the command is complete and
|
|
|
|
valid; \code{None} if the command is incomplete; raises
|
|
|
|
\exception{SyntaxError} if the command is complete and contains a
|
2001-08-27 17:02:17 -03:00
|
|
|
syntax error, or raises \exception{OverflowError} or
|
2004-05-12 00:07:27 -03:00
|
|
|
\exception{ValueError} if the command contains an invalid literal.
|
1997-07-18 18:08:07 -03:00
|
|
|
\end{funcdesc}
|
2000-04-03 17:13:55 -03:00
|
|
|
|
|
|
|
|
|
|
|
\subsection{Interactive Interpreter Objects
|
|
|
|
\label{interpreter-objects}}
|
|
|
|
|
|
|
|
\begin{methoddesc}{runsource}{source\optional{, filename\optional{, symbol}}}
|
|
|
|
Compile and run some source in the interpreter.
|
|
|
|
Arguments are the same as for \function{compile_command()}; the
|
|
|
|
default for \var{filename} is \code{'<input>'}, and for
|
|
|
|
\var{symbol} is \code{'single'}. One several things can happen:
|
|
|
|
|
|
|
|
\begin{itemize}
|
|
|
|
\item
|
|
|
|
The input is incorrect; \function{compile_command()} raised an
|
|
|
|
exception (\exception{SyntaxError} or \exception{OverflowError}). A
|
|
|
|
syntax traceback will be printed by calling the
|
|
|
|
\method{showsyntaxerror()} method. \method{runsource()} returns
|
2002-04-04 22:21:09 -04:00
|
|
|
\code{False}.
|
2000-04-03 17:13:55 -03:00
|
|
|
|
|
|
|
\item
|
|
|
|
The input is incomplete, and more input is required;
|
|
|
|
\function{compile_command()} returned \code{None}.
|
2002-04-04 22:21:09 -04:00
|
|
|
\method{runsource()} returns \code{True}.
|
2000-04-03 17:13:55 -03:00
|
|
|
|
|
|
|
\item
|
|
|
|
The input is complete; \function{compile_command()} returned a code
|
|
|
|
object. The code is executed by calling the \method{runcode()} (which
|
|
|
|
also handles run-time exceptions, except for \exception{SystemExit}).
|
2002-04-04 22:21:09 -04:00
|
|
|
\method{runsource()} returns \code{False}.
|
2000-04-03 17:13:55 -03:00
|
|
|
\end{itemize}
|
|
|
|
|
|
|
|
The return value can be used to decide whether to use
|
|
|
|
\code{sys.ps1} or \code{sys.ps2} to prompt the next line.
|
|
|
|
\end{methoddesc}
|
|
|
|
|
|
|
|
\begin{methoddesc}{runcode}{code}
|
|
|
|
Execute a code object.
|
|
|
|
When an exception occurs, \method{showtraceback()} is called to
|
|
|
|
display a traceback. All exceptions are caught except
|
2000-07-16 16:01:10 -03:00
|
|
|
\exception{SystemExit}, which is allowed to propagate.
|
2000-04-03 17:13:55 -03:00
|
|
|
|
|
|
|
A note about \exception{KeyboardInterrupt}: this exception may occur
|
|
|
|
elsewhere in this code, and may not always be caught. The caller
|
|
|
|
should be prepared to deal with it.
|
|
|
|
\end{methoddesc}
|
|
|
|
|
|
|
|
\begin{methoddesc}{showsyntaxerror}{\optional{filename}}
|
|
|
|
Display the syntax error that just occurred. This does not display
|
|
|
|
a stack trace because there isn't one for syntax errors.
|
|
|
|
If \var{filename} is given, it is stuffed into the exception instead
|
|
|
|
of the default filename provided by Python's parser, because it
|
|
|
|
always uses \code{'<string>'} when reading from a string.
|
|
|
|
The output is written by the \method{write()} method.
|
|
|
|
\end{methoddesc}
|
|
|
|
|
|
|
|
\begin{methoddesc}{showtraceback}{}
|
|
|
|
Display the exception that just occurred. We remove the first stack
|
|
|
|
item because it is within the interpreter object implementation.
|
|
|
|
The output is written by the \method{write()} method.
|
|
|
|
\end{methoddesc}
|
|
|
|
|
|
|
|
\begin{methoddesc}{write}{data}
|
2000-09-14 17:42:53 -03:00
|
|
|
Write a string to the standard error stream (\code{sys.stderr}).
|
|
|
|
Derived classes should override this to provide the appropriate output
|
|
|
|
handling as needed.
|
2000-04-03 17:13:55 -03:00
|
|
|
\end{methoddesc}
|
|
|
|
|
|
|
|
|
|
|
|
\subsection{Interactive Console Objects
|
|
|
|
\label{console-objects}}
|
|
|
|
|
|
|
|
The \class{InteractiveConsole} class is a subclass of
|
|
|
|
\class{InteractiveInterpreter}, and so offers all the methods of the
|
|
|
|
interpreter objects as well as the following additions.
|
|
|
|
|
|
|
|
\begin{methoddesc}{interact}{\optional{banner}}
|
|
|
|
Closely emulate the interactive Python console.
|
|
|
|
The optional banner argument specify the banner to print before the
|
|
|
|
first interaction; by default it prints a banner similar to the one
|
|
|
|
printed by the standard Python interpreter, followed by the class
|
|
|
|
name of the console object in parentheses (so as not to confuse this
|
|
|
|
with the real interpreter -- since it's so close!).
|
|
|
|
\end{methoddesc}
|
|
|
|
|
|
|
|
\begin{methoddesc}{push}{line}
|
|
|
|
Push a line of source text to the interpreter.
|
|
|
|
The line should not have a trailing newline; it may have internal
|
|
|
|
newlines. The line is appended to a buffer and the interpreter's
|
|
|
|
\method{runsource()} method is called with the concatenated contents
|
|
|
|
of the buffer as source. If this indicates that the command was
|
|
|
|
executed or invalid, the buffer is reset; otherwise, the command is
|
|
|
|
incomplete, and the buffer is left as it was after the line was
|
2002-04-04 22:21:09 -04:00
|
|
|
appended. The return value is \code{True} if more input is required,
|
|
|
|
\code{False} if the line was dealt with in some way (this is the same as
|
2000-04-03 17:13:55 -03:00
|
|
|
\method{runsource()}).
|
|
|
|
\end{methoddesc}
|
|
|
|
|
|
|
|
\begin{methoddesc}{resetbuffer}{}
|
|
|
|
Remove any unhandled source text from the input buffer.
|
|
|
|
\end{methoddesc}
|
|
|
|
|
|
|
|
\begin{methoddesc}{raw_input}{\optional{prompt}}
|
|
|
|
Write a prompt and read a line. The returned line does not include
|
|
|
|
the trailing newline. When the user enters the \EOF{} key sequence,
|
|
|
|
\exception{EOFError} is raised. The base implementation uses the
|
|
|
|
built-in function \function{raw_input()}; a subclass may replace this
|
|
|
|
with a different implementation.
|
|
|
|
\end{methoddesc}
|