forked from rrcarlosr/Jetpack
302 lines
7.9 KiB
C
302 lines
7.9 KiB
C
/*
|
|
* drivers/thermal/userspace_alert.c
|
|
*
|
|
* Userspace thermal alert cooling device.
|
|
*
|
|
* Copyright (C) 2016-2017 NVIDIA Corporation. All rights reserved.
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
* published by the Free Software Foundation.
|
|
*
|
|
* This program is distributed in the hope that it will be useful, but WITHOUT
|
|
* ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or
|
|
* FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for
|
|
* more details.
|
|
*/
|
|
|
|
#include <linux/kernel.h>
|
|
#include <linux/module.h>
|
|
#include <linux/kthread.h>
|
|
#include <linux/thermal.h>
|
|
#include <linux/platform_device.h>
|
|
|
|
/* Define cooling device alert state */
|
|
#define NO_ALERT 0
|
|
#define ALERT 1
|
|
|
|
/* Maximum throttle states supported */
|
|
#define CDEV_MAX_STATE ALERT
|
|
|
|
struct usr_alrt_strct {
|
|
unsigned long cur_state;
|
|
struct thermal_cooling_device *cdev;
|
|
uint32_t therm_alert;
|
|
uint32_t alert_timeout_ms;
|
|
wait_queue_head_t alert_wait_queue;
|
|
struct mutex alert_timeout_lock;
|
|
struct mutex alert_lock;
|
|
bool syfs_created;
|
|
bool syfs_symlink_created;
|
|
};
|
|
|
|
static int userspace_alert_send_uevent(struct thermal_cooling_device *tcd)
|
|
{
|
|
char trip[25];
|
|
char *envp[] = { trip, NULL };
|
|
int ret = 0;
|
|
|
|
snprintf(trip, sizeof(trip), "USERSPACE_ALERT=%s", "TRIPPED");
|
|
|
|
ret = kobject_uevent_env(&tcd->device.kobj, KOBJ_CHANGE, envp);
|
|
if (ret < 0)
|
|
pr_err("userspace_alert_send_uevent: kobj_uevent error!\n");
|
|
|
|
return ret;
|
|
}
|
|
|
|
/* Get maximum throttle state supported by cooling device. */
|
|
static int userspace_alert_cdev_max_state(struct thermal_cooling_device *tcd,
|
|
unsigned long *state)
|
|
{
|
|
struct usr_alrt_strct *alert_data = tcd->devdata;
|
|
|
|
if (!alert_data)
|
|
return -EINVAL;
|
|
|
|
*state = CDEV_MAX_STATE;
|
|
return 0;
|
|
}
|
|
|
|
/* Get current throttle state of the cooling device. */
|
|
static int userspace_alert_cdev_cur_state(struct thermal_cooling_device *tcd,
|
|
unsigned long *state)
|
|
{
|
|
struct usr_alrt_strct *alert_data = tcd->devdata;
|
|
|
|
if (!alert_data)
|
|
return -EINVAL;
|
|
|
|
*state = alert_data->cur_state;
|
|
return 0;
|
|
}
|
|
|
|
/* Set current throttle state of the cooling device. */
|
|
static int userspace_alert_cdev_set_state(struct thermal_cooling_device *tcd,
|
|
unsigned long state)
|
|
{
|
|
struct usr_alrt_strct *alert_data = tcd->devdata;
|
|
|
|
if (!alert_data)
|
|
return -EINVAL;
|
|
|
|
if (state == alert_data->cur_state)
|
|
return 0;
|
|
|
|
mutex_lock(&alert_data->alert_lock);
|
|
alert_data->cur_state = state;
|
|
|
|
if (state > 0) {
|
|
/* Send 'uevent' notification to userspace */
|
|
userspace_alert_send_uevent(tcd);
|
|
alert_data->therm_alert = ALERT;
|
|
|
|
/*
|
|
* Write barrier for other processes to see the therm_alert
|
|
* updated value.
|
|
*/
|
|
smp_wmb();
|
|
|
|
/* Wakeup the processes waiting for the alert to occur */
|
|
if (waitqueue_active(&alert_data->alert_wait_queue))
|
|
wake_up_all(&alert_data->alert_wait_queue);
|
|
|
|
pr_debug("thermal alert: USERSPACE_ALERT_TRIPPED!\n");
|
|
} else {
|
|
alert_data->therm_alert = NO_ALERT;
|
|
/*
|
|
* Write barrier for other processes to see the therm_alert
|
|
* updated value.
|
|
*/
|
|
smp_wmb();
|
|
}
|
|
mutex_unlock(&alert_data->alert_lock);
|
|
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Blocks the read call until an alert occurs or the specified duration
|
|
* times out. When alert occurs or if alert is preset, then read return
|
|
* with value 1
|
|
*/
|
|
static ssize_t thermal_alert_block_show(struct device *dev,
|
|
struct device_attribute *attr, char *buf)
|
|
{
|
|
uint32_t alert_timeout_ms;
|
|
struct usr_alrt_strct *alert_data = dev_get_drvdata(dev);
|
|
|
|
if (!alert_data)
|
|
return -EINVAL;
|
|
|
|
alert_timeout_ms = alert_data->alert_timeout_ms;
|
|
if (alert_timeout_ms > 0)
|
|
wait_event_interruptible_timeout(alert_data->alert_wait_queue,
|
|
alert_data->therm_alert == ALERT,
|
|
msecs_to_jiffies(alert_timeout_ms));
|
|
else
|
|
wait_event_interruptible(
|
|
alert_data->alert_wait_queue,
|
|
alert_data->therm_alert == ALERT);
|
|
|
|
return sprintf(buf, "%d\n", alert_data->therm_alert);
|
|
}
|
|
|
|
static ssize_t thermal_alert_show(struct device *dev,
|
|
struct device_attribute *attr, char *buf)
|
|
{
|
|
struct usr_alrt_strct *alert_data = dev_get_drvdata(dev);
|
|
|
|
if (!alert_data)
|
|
return -EINVAL;
|
|
|
|
return sprintf(buf, "%d\n", alert_data->therm_alert);
|
|
}
|
|
|
|
/*
|
|
* Set the time out duration(in ms) to wait when alert is not preset.
|
|
* When alert occurs or if alert is already preset, this value has
|
|
* no significance
|
|
*/
|
|
static ssize_t thermal_alert_block_store(struct device *dev,
|
|
struct device_attribute *attr,
|
|
const char *buf, size_t count)
|
|
{
|
|
long val;
|
|
struct usr_alrt_strct *alert_data = dev_get_drvdata(dev);
|
|
|
|
if (!alert_data)
|
|
return -EINVAL;
|
|
|
|
if (kstrtol(buf, 0, &val))
|
|
return -EINVAL;
|
|
|
|
mutex_lock(&alert_data->alert_timeout_lock);
|
|
alert_data->alert_timeout_ms = val;
|
|
mutex_unlock(&alert_data->alert_timeout_lock);
|
|
|
|
return count;
|
|
}
|
|
|
|
/*
|
|
* Cooling device operations.
|
|
*/
|
|
static struct thermal_cooling_device_ops userspace_alert_cdev_ops = {
|
|
.get_max_state = userspace_alert_cdev_max_state,
|
|
.get_cur_state = userspace_alert_cdev_cur_state,
|
|
.set_cur_state = userspace_alert_cdev_set_state,
|
|
};
|
|
|
|
static DEVICE_ATTR(thermal_alert_block, S_IRUGO | S_IWUSR,
|
|
thermal_alert_block_show, thermal_alert_block_store);
|
|
static DEVICE_ATTR(thermal_alert, S_IRUGO, thermal_alert_show, NULL);
|
|
|
|
static const struct attribute *userspace_cdev_attr[] = {
|
|
&dev_attr_thermal_alert_block.attr,
|
|
&dev_attr_thermal_alert.attr,
|
|
NULL,
|
|
};
|
|
|
|
static int userspace_alert_therm_probe(struct platform_device *pdev)
|
|
{
|
|
struct device *dev = &pdev->dev;
|
|
const char *str;
|
|
char *cdev_type;
|
|
struct usr_alrt_strct *alert_data;
|
|
struct device_node *np = dev->of_node;
|
|
|
|
alert_data = devm_kzalloc(dev, sizeof(struct usr_alrt_strct),
|
|
GFP_KERNEL);
|
|
if (!alert_data)
|
|
return -ENOMEM;
|
|
|
|
if (of_property_read_string(np, "cdev-type", &str) == 0) {
|
|
cdev_type = (char *)str;
|
|
} else {
|
|
dev_err(dev, "missing cdev-type\n");
|
|
return -EINVAL;
|
|
}
|
|
|
|
alert_data->cur_state = NO_ALERT;
|
|
alert_data->therm_alert = 0;
|
|
alert_data->alert_timeout_ms = 0;
|
|
alert_data->syfs_created = 0;
|
|
alert_data->syfs_symlink_created = 0;
|
|
mutex_init(&alert_data->alert_lock);
|
|
mutex_init(&alert_data->alert_timeout_lock);
|
|
init_waitqueue_head(&alert_data->alert_wait_queue);
|
|
dev_set_drvdata(dev, alert_data);
|
|
|
|
alert_data->cdev = thermal_of_cooling_device_register(np, cdev_type,
|
|
alert_data, &userspace_alert_cdev_ops);
|
|
|
|
if (IS_ERR(alert_data->cdev))
|
|
return PTR_ERR(alert_data->cdev);
|
|
|
|
if (sysfs_create_files(&dev->kobj, userspace_cdev_attr) < 0)
|
|
pr_warn("\n userspace alert cdev: failed to create sysfs files\n");
|
|
else
|
|
alert_data->syfs_created = 1;
|
|
|
|
|
|
if (sysfs_create_link(&alert_data->cdev->device.kobj, &dev->kobj,
|
|
"userspace_alert") < 0)
|
|
pr_warn("\n userspace alert cdev: failed to create sysfs symlink\n");
|
|
else
|
|
alert_data->syfs_symlink_created = 1;
|
|
|
|
pr_info("%s cooling device registered.\n", cdev_type);
|
|
return 0;
|
|
}
|
|
|
|
static int userspace_alert_therm_remove(struct platform_device *pdev)
|
|
{
|
|
struct device *dev = &pdev->dev;
|
|
struct usr_alrt_strct *alert_data = dev_get_drvdata(dev);
|
|
struct thermal_cooling_device *cdev;
|
|
|
|
if (alert_data) {
|
|
cdev = alert_data->cdev;
|
|
if ((cdev != NULL) && (alert_data->syfs_symlink_created))
|
|
sysfs_remove_link(&cdev->device.kobj,
|
|
"userspace_alert");
|
|
if (alert_data->syfs_created)
|
|
sysfs_remove_files(&dev->kobj, userspace_cdev_attr);
|
|
mutex_destroy(&alert_data->alert_lock);
|
|
mutex_destroy(&alert_data->alert_timeout_lock);
|
|
thermal_cooling_device_unregister(alert_data->cdev);
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
static const struct of_device_id userspace_therm_of_match[] = {
|
|
{ .compatible = "userspace-therm-alert", },
|
|
{ },
|
|
};
|
|
|
|
static struct platform_driver userspace_therm_driver = {
|
|
.driver = {
|
|
.name = "userspace-therm-alert",
|
|
.owner = THIS_MODULE,
|
|
.of_match_table = userspace_therm_of_match,
|
|
},
|
|
.probe = userspace_alert_therm_probe,
|
|
.remove = userspace_alert_therm_remove,
|
|
};
|
|
|
|
module_platform_driver(userspace_therm_driver);
|
|
|
|
MODULE_DESCRIPTION("Userspace thermal alert cooling device module");
|
|
MODULE_AUTHOR("NVIDIA");
|
|
MODULE_LICENSE("GPL v2");
|