px4-firmware/ROMFS/mixers
Lorenz Meier 7127c106cb Missing removed file 2012-08-20 23:53:09 +02:00
..
FMU_AERT.mix Adjust sample mixer configurations and documentation to match new syntax. 2012-08-11 11:28:05 -07:00
FMU_AET.mix Adjust sample mixer configurations and documentation to match new syntax. 2012-08-11 11:28:05 -07:00
FMU_RET.mix Adjust sample mixer configurations and documentation to match new syntax. 2012-08-11 11:28:05 -07:00
FMU_delta.mix Adjust sample mixer configurations and documentation to match new syntax. 2012-08-11 11:28:05 -07:00
FMU_pass.mix Adjust sample mixer configurations and documentation to match new syntax. 2012-08-11 11:28:05 -07:00
FMU_quad_+.mix Porting to new param interface, updated mixers 2012-08-20 23:52:13 +02:00
FMU_quad_x.mix Porting to new param interface, updated mixers 2012-08-20 23:52:13 +02:00
README New multirotor mixer; builds, not yet tested. 2012-08-15 00:46:15 -07:00

README

PX4 mixer definitions
=====================

Files in this directory implement example mixers that can be used as a basis
for customisation, or for general testing purposes.

Mixer basics
------------

Mixers combine control values from various sources (control tasks, user inputs,
etc.) and produce output values suitable for controlling actuators; servos,
motors, switches and so on.

An actuator derives its value from the combination of one or more control
values. Each of the control values is scaled according to the actuator's
configuration and then combined to produce the actuator value, which may then be
further scaled to suit the specific output type.

Internally, all scaling is performed using floating point values. Inputs and
outputs are clamped to the range -1.0 to 1.0.

control    control   control
   |          |         |
   v          v         v
 scale      scale     scale
   |          |         |
   |          v         |
   +-------> mix <------+
              |
            scale
              |
              v
             out

Scaling
-------

Basic scalers provide linear scaling of the input to the output.

Each scaler allows the input value to be scaled independently for inputs
greater/less than zero. An offset can be applied to the output, and lower and
upper boundary constraints can be applied. Negative scaling factors cause the
output to be inverted (negative input produces positive output).

Scaler pseudocode:

if (input < 0)
    output = (input * NEGATIVE_SCALE) + OFFSET
else
    output = (input * POSITIVE_SCALE) + OFFSET

if (output < LOWER_LIMIT)
    output = LOWER_LIMIT
if (output > UPPER_LIMIT)
    output = UPPER_LIMIT

Syntax
------

Mixer definitions are text files; lines beginning with a single capital letter
followed by a colon are significant. All other lines are ignored, meaning that
explanatory text can be freely mixed with the definitions.

Each file may define more than one mixer; the allocation of mixers to actuators
is specific to the device reading the mixer definition, and the number of
actuator outputs generated by a mixer is specific to the mixer.

A mixer begins with a line of the form

	<tag>: <mixer arguments>

The tag selects the mixer type; 'M' for a simple summing mixer, 'R' for a 
multirotor mixer, etc.

Null Mixer
..........

A null mixer consumes no controls and generates a single actuator output whose
value is always zero.  Typically a null mixer is used as a placeholder in a
collection of mixers in order to achieve a specific pattern of actuator outputs.

The null mixer definition has the form:

  Z:

Simple Mixer
............

A simple mixer combines zero or more control inputs into a single actuator
output.  Inputs are scaled, and the mixing function sums the result before
applying an output scaler.

A simple mixer definition begins with:

  M: <control count>
  O: <-ve scale> <+ve scale> <offset> <lower limit> <upper limit>

If <control count> is zero, the sum is effectively zero and the mixer will
output a fixed value that is <offset> constrained by <lower limit> and <upper
limit>.

The second line defines the output scaler with scaler parameters as discussed
above. Whilst the calculations are performed as floating-point operations, the
values stored in the definition file are scaled by a factor of 10000; i.e. an
offset of -0.5 is encoded as -5000.

The definition continues with <control count> entries describing the control
inputs and their scaling, in the form:

  S: <group> <index> <-ve scale> <+ve scale> <offset> <lower limit> <upper limit>

The <group> value identifies the control group from which the scaler will read,
and the <index> value an offset within that group.  These values are specific to
the device reading the mixer definition.

When used to mix vehicle controls, mixer group zero is the vehicle attitude
control group, and index values zero through three are normally roll, pitch,
yaw and thrust respectively.

The remaining fields on the line configure the control scaler with parameters as
discussed above. Whilst the calculations are performed as floating-point
operations, the values stored in the definition file are scaled by a factor of
10000; i.e. an offset of -0.5 is encoded as -5000.

Multirotor Mixer
................

The multirotor mixer combines four control inputs (roll, pitch, yaw, thrust)
into a set of actuator outputs intended to drive motor speed controllers.

The mixer definition is a single line of the form:

R: <geometry> <roll scale> <pitch scale> <yaw scale> <deadband>

The supported geometries include:

  4x - quadrotor in X configuration
  4+ - quadrotor in + configuration
  6x - hexcopter in X configuration
  6+ - hexcopter in + configuration
  8x - octocopter in X configuration
  8+ - octocopter in + configuration
  
Each of the roll, pitch and yaw scale values determine scaling of the roll,
pitch and yaw controls relative to the thrust control.  Whilst the calculations
are performed as floating-point operations, the values stored in the definition
file are scaled by a factor of 10000; i.e. an factor of 0.5 is encoded as 5000.

Roll, pitch and yaw inputs are expected to range from -1.0 to 1.0, whilst the
thrust input ranges from 0.0 to 1.0.  Output for each actuator is in the 
range -1.0 to 1.0.

In the case where an actuator saturates, all actuator values are rescaled so that 
the saturating actuator is limited to 1.0.