Aileron/elevator/throttle mixer for PX4FMU
|
|
==================================================
|
|
|
|
This file defines mixers suitable for controlling a fixed wing aircraft with
|
|
aileron, elevator and throttle controls using PX4FMU. The configuration assumes
|
|
the aileron servo(s) are connected to PX4FMU servo output 0, the elevator to
|
|
output 1 and the throttle to output 3.
|
|
|
|
Inputs to the mixer come from channel group 0 (vehicle attitude), channels 0
|
|
(roll), 1 (pitch) and 3 (thrust).
|
|
|
|
Aileron mixer
|
|
-------------
|
|
Two scalers total (output, roll).
|
|
|
|
This mixer assumes that the aileron servos are set up correctly mechanically;
|
|
depending on the actual configuration it may be necessary to reverse the scaling
|
|
factors (to reverse the servo movement) and adjust the offset, scaling and
|
|
endpoints to suit.
|
|
|
|
As there is only one output, if using two servos adjustments to compensate for
|
|
differences between the servos must be made mechanically. To obtain the correct
|
|
motion using a Y cable, the servos can be positioned reversed from one another.
|
|
|
|
Alternatively, output 2 could be used as a second aileron servo output with
|
|
separate mixing.
|
|
|
|
M: 1
|
|
O: 10000 10000 0 -10000 10000
|
|
S: 0 0 10000 10000 0 -10000 10000
|
|
|
|
Elevator mixer
|
|
------------
|
|
Two scalers total (output, roll).
|
|
|
|
This mixer assumes that the elevator servo is set up correctly mechanically;
|
|
depending on the actual configuration it may be necessary to reverse the scaling
|
|
factors (to reverse the servo movement) and adjust the offset, scaling and
|
|
endpoints to suit.
|
|
|
|
M: 1
|
|
O: 10000 10000 0 -10000 10000
|
|
S: 0 1 10000 10000 0 -10000 10000
|
|
|
|
Output 2
|
|
--------
|
|
This mixer is empty.
|
|
|
|
Z:
|
|
|
|
Motor speed mixer
|
|
-----------------
|
|
Two scalers total (output, thrust).
|
|
|
|
This mixer generates a full-range output (-1 to 1) from an input in the (0 - 1)
|
|
range. Inputs below zero are treated as zero.
|
|
|
|
M: 1
|
|
O: 10000 10000 0 -10000 10000
|
|
S: 0 3 0 20000 -10000 -10000 10000
|