Clarify SDLOG_MODE bit for thermal calibration

This commit is contained in:
Hamish Willee 2018-10-08 14:20:44 +11:00 committed by Beat Küng
parent 62d71bf36c
commit f1130a4e10
1 changed files with 1 additions and 1 deletions

View File

@ -15,7 +15,7 @@ Data can be gathered using the following sequence:
1) Power up the board and set the TC_A_ENABLE, TC_B_ENABLE and TC_G_ENABLE parameters to 1
2) Set all CAL_GYR and CAL_ACC parameters to defaults
3) Set the SDLOG_MODE parameter to 2, and SDLOG_PROFILE parameter to 4 to enable logging of sensor data for calibration and power off
3) Set the parameter SDLOG_MODE to 2, and SDLOG_PROFILE "Thermal calibration" bit (2) to enable logging of sensor data for calibration and power off
4) Cold soak the board for 30 minutes
5) Move to a warm dry, still air, constant pressure environment.
6) Apply power for 45 minutes, keeping the board still.