ekf2: disable multi-EKF across mags by default (H7 & SITL) for now

- re-enable once the estimator selector respects configured mag
priority (at least initially) or is otherwise able to automatically
prefer an external mag over internal
 - for SITL disabled because the full matrix of esitmator instances
(IMUs X mags) was too many topics for logger currently
This commit is contained in:
Daniel Agar 2023-05-19 11:05:04 -04:00
parent 74105907c9
commit bb0f2875a9
8 changed files with 0 additions and 19 deletions

View File

@ -47,8 +47,6 @@ param set-default PWM_MAIN_REV 96 # invert both elevons
# Single-EKF (for replay)
param set-default EKF2_MULTI_IMU 0
param set-default SENS_IMU_MODE 1
param set-default EKF2_MULTI_MAG 0
param set-default SENS_MAG_MODE 1
param set-default NPFG_PERIOD 12
param set-default FW_PR_I 0.2

View File

@ -168,8 +168,6 @@ param set-default EKF2_REQ_GPS_H 0.5
# Multi-EKF
param set-default EKF2_MULTI_IMU 3
param set-default SENS_IMU_MODE 0
param set-default EKF2_MULTI_MAG 2
param set-default SENS_MAG_MODE 0
param set-default IMU_GYRO_FFT_EN 1
param set-default MAV_PROTO_VER 2 # Ensures QGC does not drop the first few packets after a SITL restart due to MAVLINK 1 packets

View File

@ -11,11 +11,6 @@ param set-default COM_ARM_SDCARD 0
param set-default SENS_EXT_I2C_PRB 0
param set-default EKF2_MULTI_IMU 1
param set-default EKF2_MULTI_MAG 1
param set-default SENS_IMU_MODE 0
param set-default SENS_MAG_MODE 0
param set-default EV_TSK_STAT_DIS 1
param set-default SYS_DM_BACKEND 1

View File

@ -26,8 +26,6 @@ else
# Multi-EKF
param set-default EKF2_MULTI_IMU 2
param set-default SENS_IMU_MODE 0
param set-default EKF2_MULTI_MAG 2
param set-default SENS_MAG_MODE 0
fi
rgbled_pwm start

View File

@ -6,8 +6,6 @@
# Multi-EKF (off by default)
param set-default EKF2_MULTI_IMU 0
param set-default SENS_IMU_MODE 1
param set-default EKF2_MULTI_MAG 0
param set-default SENS_MAG_MODE 1
set LOGGER_BUF 8

View File

@ -6,8 +6,6 @@
# Multi-EKF (off by default)
param set-default EKF2_MULTI_IMU 0
param set-default SENS_IMU_MODE 1
param set-default EKF2_MULTI_MAG 0
param set-default SENS_MAG_MODE 1
set LOGGER_BUF 8

View File

@ -6,8 +6,6 @@
# Multi-EKF (across IMUs only)
param set-default EKF2_MULTI_IMU 3
param set-default SENS_IMU_MODE 0
param set-default EKF2_MULTI_MAG 0
param set-default SENS_MAG_MODE 1
param set-default -s IMU_GYRO_FFT_EN 1

View File

@ -6,8 +6,6 @@
# Multi-EKF
param set-default EKF2_MULTI_IMU 3
param set-default SENS_IMU_MODE 0
param set-default EKF2_MULTI_MAG 3
param set-default SENS_MAG_MODE 0
param set-default -s IMU_GYRO_FFT_EN 1