Ardupilot2/libraries/AP_BattMonitor/AP_BattMonitor_Generator.cpp
Mykhailo Kuznietsov ff70921eca AP_BattMonitor: Fix some typos
Fixed some typos found in the code.
2023-10-12 18:30:42 +11:00

160 lines
4.6 KiB
C++

/*
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include "AP_BattMonitor_config.h"
#if AP_BATTERY_GENERATOR_ENABLED
#include <AP_Common/AP_Common.h>
#include <AP_Math/AP_Math.h>
#include "AP_BattMonitor_Generator.h"
/*
Fuel class
*/
// This is where we tell the battery monitor 'we have current' if we want to report a fuel level remaining
bool AP_BattMonitor_Generator_FuelLevel::has_current(void) const
{
// If the generator has fuel remaining we must also state that we have current
return has_consumed_energy();
}
// This is where we tell the battery monitor 'we have consumed energy' if we want to report a fuel level remaining
bool AP_BattMonitor_Generator_FuelLevel::has_consumed_energy(void) const
{
// Get pointer to generator singleton
AP_Generator *generator = AP::generator();
if (generator == nullptr) {
return false;
}
// Use consumed_mAh in BattMonitor to display fuel remaining
return generator->has_fuel_remaining();
}
void AP_BattMonitor_Generator_FuelLevel::init()
{
// Set params for users:
// Fuel level is only reported as a percentage
_params._pack_capacity.set(100);
// Fuel only reports a fixed 1v, don't want batt monitor failsafes on this instance
_params._low_voltage.set(0);
_params._critical_voltage.set(0);
}
// Read the fuel level. Should be called at 10hz
void AP_BattMonitor_Generator_FuelLevel::read()
{
_state.healthy = false;
// Get pointer to generator singleton
AP_Generator *generator = AP::generator();
// Not healthy if we can't find a generator
if (generator == nullptr) {
return;
}
if (!generator->healthy()) {
return;
}
// As this is a battery monitor instance report voltage
// Report fixed voltage of 1V
_state.voltage = 1.0f;
// This is a bodge to display tank level as a percentage on GCS. Users should set _params.pack_capacity == 100 to get a clear percentage in GCS
_state.consumed_mah = (1 - generator->get_fuel_remaining()) * _params._pack_capacity.get();
// If we got this far then must be healthy
_state.healthy = true;
_state.last_time_micros = AP_HAL::micros();
}
/*
Electrical class
*/
bool AP_BattMonitor_Generator_Elec::has_current(void) const
{
// Get pointer to generator singleton
AP_Generator *generator = AP::generator();
if (generator == nullptr) {
return false;
}
return generator->has_current();
}
bool AP_BattMonitor_Generator_Elec::has_consumed_energy(void) const
{
// Get pointer to generator singleton
AP_Generator *generator = AP::generator();
if (generator == nullptr) {
return false;
}
return generator->has_consumed_energy();
}
// Read the electrical measurements from the generator
void AP_BattMonitor_Generator_Elec::read()
{
_state.healthy = false;
// Get pointer to generator singleton
AP_Generator *generator = AP::generator();
// Not healthy if we can't find a generator
if (generator == nullptr) {
return;
}
if (!generator->healthy()) {
return;
}
// Update readings
_state.voltage = generator->get_voltage();
_state.current_amps = generator->get_current();
// Always reset consumed value, integration is done in AP_Generator library
_state.consumed_mah = generator->get_batt_consumed();
_state.consumed_wh = 0.001f * _state.consumed_mah * _state.voltage;
// If we got this far then must be healthy
_state.healthy = true;
_state.last_time_micros = AP_HAL::micros();
}
AP_BattMonitor::Failsafe AP_BattMonitor_Generator_Elec::update_failsafes()
{
AP_BattMonitor::Failsafe failsafe = AP_BattMonitor::Failsafe::None;
AP_Generator *generator = AP::generator();
// Only check for failsafes on the electrical monitor
// no point in having the same failsafe on two battery monitors
if (generator != nullptr) {
failsafe = generator->update_failsafes();
}
return MAX(AP_BattMonitor_Backend::update_failsafes(), failsafe);
}
#endif // AP_BATTERY_GENERATOR_ENABLED