mirror of https://github.com/python/cpython
583 lines
25 KiB
TeX
583 lines
25 KiB
TeX
\section{\module{sys} ---
|
|
System-specific parameters and functions}
|
|
|
|
\declaremodule{builtin}{sys}
|
|
\modulesynopsis{Access system-specific parameters and functions.}
|
|
|
|
This module provides access to some variables used or maintained by the
|
|
interpreter and to functions that interact strongly with the interpreter.
|
|
It is always available.
|
|
|
|
|
|
\begin{datadesc}{argv}
|
|
The list of command line arguments passed to a Python script.
|
|
\code{argv[0]} is the script name (it is operating system dependent
|
|
whether this is a full pathname or not). If the command was
|
|
executed using the \programopt{-c} command line option to the
|
|
interpreter, \code{argv[0]} is set to the string \code{'-c'}. If no
|
|
script name was passed to the Python interpreter, \code{argv} has
|
|
zero length.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{byteorder}
|
|
An indicator of the native byte order. This will have the value
|
|
\code{'big'} on big-endian (most-signigicant byte first) platforms,
|
|
and \code{'little'} on little-endian (least-significant byte first)
|
|
platforms.
|
|
\versionadded{2.0}
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{builtin_module_names}
|
|
A tuple of strings giving the names of all modules that are compiled
|
|
into this Python interpreter. (This information is not available in
|
|
any other way --- \code{modules.keys()} only lists the imported
|
|
modules.)
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{copyright}
|
|
A string containing the copyright pertaining to the Python
|
|
interpreter.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{dllhandle}
|
|
Integer specifying the handle of the Python DLL.
|
|
Availability: Windows.
|
|
\end{datadesc}
|
|
|
|
\begin{funcdesc}{displayhook}{\var{value}}
|
|
If \var{value} is not \code{None}, this function prints it to
|
|
\code{sys.stdout}, and saves it in \code{__builtin__._}.
|
|
|
|
\code{sys.displayhook} is called on the result of evaluating an
|
|
expression entered in an interactive Python session. The display of
|
|
these values can be customized by assigning another one-argument
|
|
function to \code{sys.displayhook}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{excepthook}{\var{type}, \var{value}, \var{traceback}}
|
|
This function prints out a given traceback and exception to
|
|
\code{sys.stderr}.
|
|
|
|
When an exception is raised and uncaught, the interpreter calls
|
|
\code{sys.excepthook} with three arguments, the exception class,
|
|
exception instance, and a traceback object. In an interactive
|
|
session this happens just before control is returned to the prompt;
|
|
in a Python program this happens just before the program exits. The
|
|
handling of such top-level exceptions can be customized by assigning
|
|
another three-argument function to \code{sys.excepthook}.
|
|
\end{funcdesc}
|
|
|
|
\begin{datadesc}{__displayhook__}
|
|
\dataline{__excepthook__}
|
|
These objects contain the original values of \code{displayhook} and
|
|
\code{excepthook} at the start of the program. They are saved so
|
|
that \code{displayhook} and \code{excepthook} can be restored in
|
|
case they happen to get replaced with broken objects.
|
|
\end{datadesc}
|
|
|
|
\begin{funcdesc}{exc_info}{}
|
|
This function returns a tuple of three values that give information
|
|
about the exception that is currently being handled. The
|
|
information returned is specific both to the current thread and to
|
|
the current stack frame. If the current stack frame is not handling
|
|
an exception, the information is taken from the calling stack frame,
|
|
or its caller, and so on until a stack frame is found that is
|
|
handling an exception. Here, ``handling an exception'' is defined
|
|
as ``executing or having executed an except clause.'' For any stack
|
|
frame, only information about the most recently handled exception is
|
|
accessible.
|
|
|
|
If no exception is being handled anywhere on the stack, a tuple
|
|
containing three \code{None} values is returned. Otherwise, the
|
|
values returned are \code{(\var{type}, \var{value},
|
|
\var{traceback})}. Their meaning is: \var{type} gets the exception
|
|
type of the exception being handled (a class object);
|
|
\var{value} gets the exception parameter (its \dfn{associated value}
|
|
or the second argument to \keyword{raise}, which is always a class
|
|
instance if the exception type is a class object); \var{traceback}
|
|
gets a traceback object (see the Reference Manual) which
|
|
encapsulates the call stack at the point where the exception
|
|
originally occurred. \obindex{traceback}
|
|
|
|
If \function{exc_clear()} is called, this function will return three
|
|
\code{None} values until either another exception is raised in the
|
|
current thread or the execution stack returns to a frame where
|
|
another exception is being handled.
|
|
|
|
\warning{Assigning the \var{traceback} return value to a
|
|
local variable in a function that is handling an exception will
|
|
cause a circular reference. This will prevent anything referenced
|
|
by a local variable in the same function or by the traceback from
|
|
being garbage collected. Since most functions don't need access to
|
|
the traceback, the best solution is to use something like
|
|
\code{exctype, value = sys.exc_info()[:2]} to extract only the
|
|
exception type and value. If you do need the traceback, make sure
|
|
to delete it after use (best done with a \keyword{try}
|
|
... \keyword{finally} statement) or to call \function{exc_info()} in
|
|
a function that does not itself handle an exception.} \note{Beginning
|
|
with Python 2.2, such cycles are automatically reclaimed when garbage
|
|
collection is enabled and they become unreachable, but it remains more
|
|
efficient to avoid creating cycles.}
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{exc_clear}{}
|
|
This function clears all information relating to the current or last
|
|
exception that occured in the current thread. After calling this
|
|
function, \function{exc_info()} will return three \code{None} values until
|
|
another exception is raised in the current thread or the execution stack
|
|
returns to a frame where another exception is being handled.
|
|
|
|
This function is only needed in only a few obscure situations. These
|
|
include logging and error handling systems that report information on the
|
|
last or current exception. This function can also be used to try to free
|
|
resources and trigger object finalization, though no guarantee is made as
|
|
to what objects will be freed, if any.
|
|
\versionadded{2.3}
|
|
\end{funcdesc}
|
|
|
|
\begin{datadesc}{exc_type}
|
|
\dataline{exc_value}
|
|
\dataline{exc_traceback}
|
|
\deprecated {1.5}
|
|
{Use \function{exc_info()} instead.}
|
|
Since they are global variables, they are not specific to the
|
|
current thread, so their use is not safe in a multi-threaded
|
|
program. When no exception is being handled, \code{exc_type} is set
|
|
to \code{None} and the other two are undefined.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{exec_prefix}
|
|
A string giving the site-specific directory prefix where the
|
|
platform-dependent Python files are installed; by default, this is
|
|
also \code{'/usr/local'}. This can be set at build time with the
|
|
\longprogramopt{exec-prefix} argument to the \program{configure}
|
|
script. Specifically, all configuration files (e.g. the
|
|
\file{pyconfig.h} header file) are installed in the directory
|
|
\code{exec_prefix + '/lib/python\var{version}/config'}, and shared
|
|
library modules are installed in \code{exec_prefix +
|
|
'/lib/python\var{version}/lib-dynload'}, where \var{version} is
|
|
equal to \code{version[:3]}.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{executable}
|
|
A string giving the name of the executable binary for the Python
|
|
interpreter, on systems where this makes sense.
|
|
\end{datadesc}
|
|
|
|
\begin{funcdesc}{exit}{\optional{arg}}
|
|
Exit from Python. This is implemented by raising the
|
|
\exception{SystemExit} exception, so cleanup actions specified by
|
|
finally clauses of \keyword{try} statements are honored, and it is
|
|
possible to intercept the exit attempt at an outer level. The
|
|
optional argument \var{arg} can be an integer giving the exit status
|
|
(defaulting to zero), or another type of object. If it is an
|
|
integer, zero is considered ``successful termination'' and any
|
|
nonzero value is considered ``abnormal termination'' by shells and
|
|
the like. Most systems require it to be in the range 0-127, and
|
|
produce undefined results otherwise. Some systems have a convention
|
|
for assigning specific meanings to specific exit codes, but these
|
|
are generally underdeveloped; \UNIX{} programs generally use 2 for
|
|
command line syntax errors and 1 for all other kind of errors. If
|
|
another type of object is passed, \code{None} is equivalent to
|
|
passing zero, and any other object is printed to \code{sys.stderr}
|
|
and results in an exit code of 1. In particular,
|
|
\code{sys.exit("some error message")} is a quick way to exit a
|
|
program when an error occurs.
|
|
\end{funcdesc}
|
|
|
|
\begin{datadesc}{exitfunc}
|
|
This value is not actually defined by the module, but can be set by
|
|
the user (or by a program) to specify a clean-up action at program
|
|
exit. When set, it should be a parameterless function. This
|
|
function will be called when the interpreter exits. Only one
|
|
function may be installed in this way; to allow multiple functions
|
|
which will be called at termination, use the \refmodule{atexit}
|
|
module. \note{The exit function is not called when the program is
|
|
killed by a signal, when a Python fatal internal error is detected,
|
|
or when \code{os._exit()} is called.}
|
|
\end{datadesc}
|
|
|
|
\begin{funcdesc}{getcheckinterval}{}
|
|
Return the interpreter's ``check interval'';
|
|
see \function{setcheckinterval()}.
|
|
\versionadded{2.3}
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{getdefaultencoding}{}
|
|
Return the name of the current default string encoding used by the
|
|
Unicode implementation.
|
|
\versionadded{2.0}
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{getdlopenflags}{}
|
|
Return the current value of the flags that are used for
|
|
\cfunction{dlopen()} calls. The flag constants are defined in the
|
|
\refmodule{dl} and \module{DLFCN} modules.
|
|
Availability: \UNIX.
|
|
\versionadded{2.2}
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{getfilesystemencoding}{}
|
|
Return the name of the encoding used to convert Unicode filenames
|
|
into system file names, or \code{None} if the system default encoding
|
|
is used. The result value depends on the operating system:
|
|
\begin{itemize}
|
|
\item On Windows 9x, the encoding is ``mbcs''.
|
|
\item On Mac OS X, the encoding is ``utf-8''.
|
|
\item On Unix, the encoding is the user's preference
|
|
according to the result of nl_langinfo(CODESET), or None if
|
|
the nl_langinfo(CODESET) failed.
|
|
\item On Windows NT+, file names are Unicode natively, so no conversion
|
|
is performed. \code{getfilesystemencoding} still returns ``mbcs'',
|
|
as this is the encoding that applications should use when they
|
|
explicitly want to convert Unicode strings to byte strings that
|
|
are equivalent when used as file names.
|
|
\end{itemize}
|
|
\versionadded{2.3}
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{getrefcount}{object}
|
|
Return the reference count of the \var{object}. The count returned
|
|
is generally one higher than you might expect, because it includes
|
|
the (temporary) reference as an argument to
|
|
\function{getrefcount()}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{getrecursionlimit}{}
|
|
Return the current value of the recursion limit, the maximum depth
|
|
of the Python interpreter stack. This limit prevents infinite
|
|
recursion from causing an overflow of the C stack and crashing
|
|
Python. It can be set by \function{setrecursionlimit()}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{_getframe}{\optional{depth}}
|
|
Return a frame object from the call stack. If optional integer
|
|
\var{depth} is given, return the frame object that many calls below
|
|
the top of the stack. If that is deeper than the call stack,
|
|
\exception{ValueError} is raised. The default for \var{depth} is
|
|
zero, returning the frame at the top of the call stack.
|
|
|
|
This function should be used for internal and specialized purposes
|
|
only.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{getwindowsversion}{}
|
|
Return a tuple containing five components, describing the Windows
|
|
version currently running. The elements are \var{major}, \var{minor},
|
|
\var{build}, \var{platform}, and \var{text}. \var{text} contains
|
|
a string while all other values are integers.
|
|
|
|
\var{platform} may be one of the following values:
|
|
\begin{list}{}{\leftmargin 0.7in \labelwidth 0.65in}
|
|
\item[0 (\constant{VER_PLATFORM_WIN32s})]
|
|
Win32s on Windows 3.1.
|
|
\item[1 (\constant{VER_PLATFORM_WIN32_WINDOWS})]
|
|
Windows 95/98/ME
|
|
\item[2 (\constant{VER_PLATFORM_WIN32_NT})]
|
|
Windows NT/2000/XP
|
|
\item[3 (\constant{VER_PLATFORM_WIN32_CE})]
|
|
Windows CE.
|
|
\end{list}
|
|
|
|
This function wraps the Win32 \function{GetVersionEx()} function;
|
|
see the Microsoft Documentation for more information about these
|
|
fields.
|
|
|
|
Availability: Windows.
|
|
\versionadded{2.3}
|
|
\end{funcdesc}
|
|
|
|
\begin{datadesc}{hexversion}
|
|
The version number encoded as a single integer. This is guaranteed
|
|
to increase with each version, including proper support for
|
|
non-production releases. For example, to test that the Python
|
|
interpreter is at least version 1.5.2, use:
|
|
|
|
\begin{verbatim}
|
|
if sys.hexversion >= 0x010502F0:
|
|
# use some advanced feature
|
|
...
|
|
else:
|
|
# use an alternative implementation or warn the user
|
|
...
|
|
\end{verbatim}
|
|
|
|
This is called \samp{hexversion} since it only really looks
|
|
meaningful when viewed as the result of passing it to the built-in
|
|
\function{hex()} function. The \code{version_info} value may be
|
|
used for a more human-friendly encoding of the same information.
|
|
\versionadded{1.5.2}
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{last_type}
|
|
\dataline{last_value}
|
|
\dataline{last_traceback}
|
|
These three variables are not always defined; they are set when an
|
|
exception is not handled and the interpreter prints an error message
|
|
and a stack traceback. Their intended use is to allow an
|
|
interactive user to import a debugger module and engage in
|
|
post-mortem debugging without having to re-execute the command that
|
|
caused the error. (Typical use is \samp{import pdb; pdb.pm()} to
|
|
enter the post-mortem debugger; see chapter \ref{debugger}, ``The
|
|
Python Debugger,'' for more information.)
|
|
|
|
The meaning of the variables is the same as that of the return
|
|
values from \function{exc_info()} above. (Since there is only one
|
|
interactive thread, thread-safety is not a concern for these
|
|
variables, unlike for \code{exc_type} etc.)
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{maxint}
|
|
The largest positive integer supported by Python's regular integer
|
|
type. This is at least 2**31-1. The largest negative integer is
|
|
\code{-maxint-1} --- the asymmetry results from the use of 2's
|
|
complement binary arithmetic.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{maxunicode}
|
|
An integer giving the largest supported code point for a Unicode
|
|
character. The value of this depends on the configuration option
|
|
that specifies whether Unicode characters are stored as UCS-2 or
|
|
UCS-4.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{modules}
|
|
This is a dictionary that maps module names to modules which have
|
|
already been loaded. This can be manipulated to force reloading of
|
|
modules and other tricks. Note that removing a module from this
|
|
dictionary is \emph{not} the same as calling
|
|
\function{reload()}\bifuncindex{reload} on the corresponding module
|
|
object.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{path}
|
|
\indexiii{module}{search}{path}
|
|
A list of strings that specifies the search path for modules.
|
|
Initialized from the environment variable \envvar{PYTHONPATH}, plus an
|
|
installation-dependent default.
|
|
|
|
As initialized upon program startup,
|
|
the first item of this list, \code{path[0]}, is the directory
|
|
containing the script that was used to invoke the Python
|
|
interpreter. If the script directory is not available (e.g. if the
|
|
interpreter is invoked interactively or if the script is read from
|
|
standard input), \code{path[0]} is the empty string, which directs
|
|
Python to search modules in the current directory first. Notice
|
|
that the script directory is inserted \emph{before} the entries
|
|
inserted as a result of \envvar{PYTHONPATH}.
|
|
|
|
A program is free to modify this list for its own purposes.
|
|
|
|
\versionchanged[Unicode strings are no longer ignored]{2.3}
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{platform}
|
|
This string contains a platform identifier, e.g. \code{'sunos5'} or
|
|
\code{'linux1'}. This can be used to append platform-specific
|
|
components to \code{path}, for instance.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{prefix}
|
|
A string giving the site-specific directory prefix where the
|
|
platform independent Python files are installed; by default, this is
|
|
the string \code{'/usr/local'}. This can be set at build time with
|
|
the \longprogramopt{prefix} argument to the \program{configure}
|
|
script. The main collection of Python library modules is installed
|
|
in the directory \code{prefix + '/lib/python\var{version}'} while
|
|
the platform independent header files (all except \file{pyconfig.h})
|
|
are stored in \code{prefix + '/include/python\var{version}'}, where
|
|
\var{version} is equal to \code{version[:3]}.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{ps1}
|
|
\dataline{ps2}
|
|
\index{interpreter prompts}
|
|
\index{prompts, interpreter}
|
|
Strings specifying the primary and secondary prompt of the
|
|
interpreter. These are only defined if the interpreter is in
|
|
interactive mode. Their initial values in this case are
|
|
\code{'>\code{>}> '} and \code{'... '}. If a non-string object is
|
|
assigned to either variable, its \function{str()} is re-evaluated
|
|
each time the interpreter prepares to read a new interactive
|
|
command; this can be used to implement a dynamic prompt.
|
|
\end{datadesc}
|
|
|
|
\begin{funcdesc}{setcheckinterval}{interval}
|
|
Set the interpreter's ``check interval''. This integer value
|
|
determines how often the interpreter checks for periodic things such
|
|
as thread switches and signal handlers. The default is \code{100},
|
|
meaning the check is performed every 100 Python virtual instructions.
|
|
Setting it to a larger value may increase performance for programs
|
|
using threads. Setting it to a value \code{<=} 0 checks every
|
|
virtual instruction, maximizing responsiveness as well as overhead.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{setdefaultencoding}{name}
|
|
Set the current default string encoding used by the Unicode
|
|
implementation. If \var{name} does not match any available
|
|
encoding, \exception{LookupError} is raised. This function is only
|
|
intended to be used by the \refmodule{site} module implementation
|
|
and, where needed, by \module{sitecustomize}. Once used by the
|
|
\refmodule{site} module, it is removed from the \module{sys}
|
|
module's namespace.
|
|
% Note that \refmodule{site} is not imported if
|
|
% the \programopt{-S} option is passed to the interpreter, in which
|
|
% case this function will remain available.
|
|
\versionadded{2.0}
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{setdlopenflags}{n}
|
|
Set the flags used by the interpreter for \cfunction{dlopen()}
|
|
calls, such as when the interpreter loads extension modules. Among
|
|
other things, this will enable a lazy resolving of symbols when
|
|
importing a module, if called as \code{sys.setdlopenflags(0)}. To
|
|
share symbols across extension modules, call as
|
|
\code{sys.setdlopenflags(dl.RTLD_NOW | dl.RTLD_GLOBAL)}. Symbolic
|
|
names for the flag modules can be either found in the \refmodule{dl}
|
|
module, or in the \module{DLFCN} module. If \module{DLFCN} is not
|
|
available, it can be generated from \file{/usr/include/dlfcn.h}
|
|
using the \program{h2py} script.
|
|
Availability: \UNIX.
|
|
\versionadded{2.2}
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{setprofile}{profilefunc}
|
|
Set the system's profile function,\index{profile function} which
|
|
allows you to implement a Python source code profiler in
|
|
Python.\index{profiler} See chapter \ref{profile} for more
|
|
information on the Python profiler. The system's profile function
|
|
is called similarly to the system's trace function (see
|
|
\function{settrace()}), but it isn't called for each executed line
|
|
of code (only on call and return, but the return event is reported
|
|
even when an exception has been set). The function is
|
|
thread-specific, but there is no way for the profiler to know about
|
|
context switches between threads, so it does not make sense to use
|
|
this in the presence of multiple threads.
|
|
Also, its return value is not used, so it can simply return
|
|
\code{None}.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{setrecursionlimit}{limit}
|
|
Set the maximum depth of the Python interpreter stack to
|
|
\var{limit}. This limit prevents infinite recursion from causing an
|
|
overflow of the C stack and crashing Python.
|
|
|
|
The highest possible limit is platform-dependent. A user may need
|
|
to set the limit higher when she has a program that requires deep
|
|
recursion and a platform that supports a higher limit. This should
|
|
be done with care, because a too-high limit can lead to a crash.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{settrace}{tracefunc}
|
|
Set the system's trace function,\index{trace function} which allows
|
|
you to implement a Python source code debugger in Python. See
|
|
section \ref{debugger-hooks}, ``How It Works,'' in the chapter on
|
|
the Python debugger.\index{debugger} The function is
|
|
thread-specific; for a debugger to support multiple threads, it must
|
|
be registered using \function{settrace()} for each thread being
|
|
debugged.
|
|
\end{funcdesc}
|
|
|
|
\begin{funcdesc}{settscdump}{on_flag}
|
|
Activate dumping of VM measurements using the Pentium timestamp
|
|
counter, if \var{on_flag} is true. Deactivate these dumps if
|
|
\var{on_flag} is off. The function is available only if Python
|
|
was compiled with \longprogramopt{with-tsc}. To understand the
|
|
output of this dump, read \file{Python/ceval.c} in the Python
|
|
sources.
|
|
\versionadded{2.4}
|
|
\end{funcdesc}
|
|
|
|
\begin{datadesc}{stdin}
|
|
\dataline{stdout}
|
|
\dataline{stderr}
|
|
File objects corresponding to the interpreter's standard input,
|
|
output and error streams. \code{stdin} is used for all interpreter
|
|
input except for scripts but including calls to
|
|
\function{input()}\bifuncindex{input} and
|
|
\function{raw_input()}\bifuncindex{raw_input}. \code{stdout} is
|
|
used for the output of \keyword{print} and expression statements and
|
|
for the prompts of \function{input()} and \function{raw_input()}.
|
|
The interpreter's own prompts and (almost all of) its error messages
|
|
go to \code{stderr}. \code{stdout} and \code{stderr} needn't be
|
|
built-in file objects: any object is acceptable as long as it has a
|
|
\method{write()} method that takes a string argument. (Changing
|
|
these objects doesn't affect the standard I/O streams of processes
|
|
executed by \function{os.popen()}, \function{os.system()} or the
|
|
\function{exec*()} family of functions in the \refmodule{os}
|
|
module.)
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{__stdin__}
|
|
\dataline{__stdout__}
|
|
\dataline{__stderr__}
|
|
These objects contain the original values of \code{stdin},
|
|
\code{stderr} and \code{stdout} at the start of the program. They
|
|
are used during finalization, and could be useful to restore the
|
|
actual files to known working file objects in case they have been
|
|
overwritten with a broken object.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{tracebacklimit}
|
|
When this variable is set to an integer value, it determines the
|
|
maximum number of levels of traceback information printed when an
|
|
unhandled exception occurs. The default is \code{1000}. When set
|
|
to \code{0} or less, all traceback information is suppressed and
|
|
only the exception type and value are printed.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{version}
|
|
A string containing the version number of the Python interpreter
|
|
plus additional information on the build number and compiler used.
|
|
It has a value of the form \code{'\var{version}
|
|
(\#\var{build_number}, \var{build_date}, \var{build_time})
|
|
[\var{compiler}]'}. The first three characters are used to identify
|
|
the version in the installation directories (where appropriate on
|
|
each platform). An example:
|
|
|
|
\begin{verbatim}
|
|
>>> import sys
|
|
>>> sys.version
|
|
'1.5.2 (#0 Apr 13 1999, 10:51:12) [MSC 32 bit (Intel)]'
|
|
\end{verbatim}
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{api_version}
|
|
The C API version for this interpreter. Programmers may find this useful
|
|
when debugging version conflicts between Python and extension
|
|
modules. \versionadded{2.3}
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{version_info}
|
|
A tuple containing the five components of the version number:
|
|
\var{major}, \var{minor}, \var{micro}, \var{releaselevel}, and
|
|
\var{serial}. All values except \var{releaselevel} are integers;
|
|
the release level is \code{'alpha'}, \code{'beta'},
|
|
\code{'candidate'}, or \code{'final'}. The \code{version_info}
|
|
value corresponding to the Python version 2.0 is \code{(2, 0, 0,
|
|
'final', 0)}.
|
|
\versionadded{2.0}
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{warnoptions}
|
|
This is an implementation detail of the warnings framework; do not
|
|
modify this value. Refer to the \refmodule{warnings} module for
|
|
more information on the warnings framework.
|
|
\end{datadesc}
|
|
|
|
\begin{datadesc}{winver}
|
|
The version number used to form registry keys on Windows platforms.
|
|
This is stored as string resource 1000 in the Python DLL. The value
|
|
is normally the first three characters of \constant{version}. It is
|
|
provided in the \module{sys} module for informational purposes;
|
|
modifying this value has no effect on the registry keys used by
|
|
Python.
|
|
Availability: Windows.
|
|
\end{datadesc}
|
|
|
|
|
|
\begin{seealso}
|
|
\seemodule{site}
|
|
{This describes how to use .pth files to extend \code{sys.path}.}
|
|
\end{seealso}
|