cpython/Tools/msi/build.bat

87 lines
3.1 KiB
Batchfile

@echo off
setlocal
set D=%~dp0
set PCBUILD=%D%..\..\PCbuild\
set BUILDX86=
set BUILDX64=
set BUILDARM64=
set BUILDDOC=
set BUILDTEST=
set BUILDPACK=
set REBUILD=
:CheckOpts
if "%~1" EQU "-h" goto Help
if /I "%~1" EQU "-x86" (set BUILDX86=1) && shift && goto CheckOpts
if /I "%~1" EQU "-Win32" (set BUILDX86=1) && shift && goto CheckOpts
if /I "%~1" EQU "-x64" (set BUILDX64=1) && shift && goto CheckOpts
if /I "%~1" EQU "-arm64" (set BUILDARM64=1) && shift && goto CheckOpts
if "%~1" EQU "--doc" (set BUILDDOC=1) && shift && goto CheckOpts
if "%~1" EQU "--no-test-marker" (set BUILDTEST=) && shift && goto CheckOpts
if "%~1" EQU "--test-marker" (set BUILDTEST=--test-marker) && shift && goto CheckOpts
if "%~1" EQU "--pack" (set BUILDPACK=1) && shift && goto CheckOpts
if "%~1" EQU "-r" (set REBUILD=-r) && shift && goto CheckOpts
if not defined BUILDX86 if not defined BUILDX64 if not defined BUILDARM64 (set BUILDX86=1) && (set BUILDX64=1)
call "%D%get_externals.bat"
call "%PCBUILD%find_msbuild.bat" %MSBUILD%
if ERRORLEVEL 1 (echo Cannot locate MSBuild.exe on PATH or as MSBUILD variable & exit /b 2)
if defined BUILDX86 call "%PCBUILD%build.bat" -p Win32 -d -e %REBUILD% %BUILDTEST%
if errorlevel 1 exit /B %ERRORLEVEL%
if defined BUILDX86 call "%PCBUILD%build.bat" -p Win32 -e %REBUILD% %BUILDTEST%
if errorlevel 1 exit /B %ERRORLEVEL%
if defined BUILDX64 call "%PCBUILD%build.bat" -p x64 -d -e %REBUILD% %BUILDTEST%
if errorlevel 1 exit /B %ERRORLEVEL%
if defined BUILDX64 call "%PCBUILD%build.bat" -p x64 -e %REBUILD% %BUILDTEST%
if errorlevel 1 exit /B %ERRORLEVEL%
if defined BUILDARM64 call "%PCBUILD%build.bat" -p ARM64 -d -e %REBUILD% %BUILDTEST%
if errorlevel 1 exit /B %ERRORLEVEL%
if defined BUILDARM64 call "%PCBUILD%build.bat" -p ARM64 -e %REBUILD% %BUILDTEST%
if errorlevel 1 exit /B %ERRORLEVEL%
if defined BUILDDOC call "%PCBUILD%..\Doc\make.bat" html
if errorlevel 1 exit /B %ERRORLEVEL%
rem Build the launcher MSI separately
%MSBUILD% "%D%launcher\launcher.wixproj" /p:Platform=x86
if errorlevel 1 exit /B %ERRORLEVEL%
set BUILD_CMD="%D%bundle\snapshot.wixproj"
if defined BUILDTEST (
set BUILD_CMD=%BUILD_CMD% /p:UseTestMarker=true
)
if defined BUILDPACK (
set BUILD_CMD=%BUILD_CMD% /p:Pack=true
)
if defined REBUILD (
set BUILD_CMD=%BUILD_CMD% /t:Rebuild
)
if defined BUILDX86 %MSBUILD% /p:Platform=x86 %BUILD_CMD%
if errorlevel 1 exit /B %ERRORLEVEL%
if defined BUILDX64 %MSBUILD% /p:Platform=x64 %BUILD_CMD%
if errorlevel 1 exit /B %ERRORLEVEL%
if defined BUILDARM64 %MSBUILD% /p:Platform=ARM64 %BUILD_CMD%
if errorlevel 1 exit /B %ERRORLEVEL%
exit /B 0
:Help
echo build.bat [-x86] [-x64] [-arm64] [--doc] [-h] [--test-marker] [--pack] [-r]
echo.
echo -x86 Build x86 installers
echo -x64 Build x64 installers
echo -ARM64 Build ARM64 installers
echo --doc Build documentation
echo --test-marker Build with test markers
echo --no-test-marker Build without test markers (default)
echo --pack Embed core MSIs into installer
echo -r Rebuild rather than incremental build