* _add_python_opts() now handles cross compilation and HOSTRUNNER.
* display_header() now tells if Python is cross-compiled, display
HOSTRUNNER, and get the host platform.
* Remove Tools/scripts/run_tests.py script.
* Remove "make hostrunnertest": use "make buildbottest"
or "make test" instead.
* Refactor os_sched_getaffinity_impl(): move variable definitions to
their first assignment.
* Fix test_posix.test_sched_getaffinity(): restore the old CPU mask
when the test completes!
* Doc: Specify that os.cpu_count() counts *logicial* CPUs.
* Doc: Specify that os.sched_getaffinity(0) is related to the calling
thread.
Rename WORKER_ERROR to WORKER_BUG. Add WORKER_FAILED state: it does
not stop the manager, whereas WORKER_BUG does.
Change also TestResults.display_result() order: display failed tests
at the end, the important important information.
WorkerThread now tries to get the signal name for negative exit code.
* Remove unused <locale.h> includes.
* Remove unused <fcntl.h> include in traceback.h.
* Remove redundant <assert.h> and <stddef.h> includes. They are already
included by "Python.h".
* Remove <object.h> include in faulthandler.c. Python.h already includes it.
* Add missing <stdbool.h> in pycore_pythread.h if HAVE_PTHREAD_STUBS
is defined.
* Fix also warnings in pthread_stubs.h: don't redefine macros if they
are already defined, like the __NEED_pthread_t macro.
Call also copy_python_src_ignore() on listdir() names.
shutil.copytree(): replace set() with an empty tuple. An empty tuple
becomes a constant in the compiler and checking if an item is in an
empty tuple is cheap.
* pycore_pythread.h is now the central place to make sure that
_POSIX_THREADS and _POSIX_SEMAPHORES macros are defined if
available.
* Make sure that pycore_pythread.h is included when _POSIX_THREADS
and _POSIX_SEMAPHORES macros are tested.
* PY_TIMEOUT_MAX is now defined as a constant, since its value
depends on _POSIX_THREADS, instead of being defined as a macro.
* Prevent integer overflow in the preprocessor when computing
PY_TIMEOUT_MAX_VALUE on Windows:
replace "0xFFFFFFFELL * 1000 < LLONG_MAX"
with "0xFFFFFFFELL < LLONG_MAX / 1000".
* Document the change and give hints how to fix affected code.
* Add an exception for PY_TIMEOUT_MAX name to smelly.py
* Add PY_TIMEOUT_MAX to the stable ABI
Add private `pathlib._PathBase` class. This will be used by an experimental PyPI package to incubate a `tarfile.TarPath` class.
Co-authored-by: Adam Turner <9087854+AA-Turner@users.noreply.github.com>
concurrent.futures: The *executor manager thread* now catches
exceptions when adding an item to the *call queue*. During Python
finalization, creating a new thread can now raise RuntimeError. Catch
the exception and call terminate_broken() in this case.
Add test_python_finalization_error() to test_concurrent_futures.
concurrent.futures._ExecutorManagerThread changes:
* terminate_broken() no longer calls shutdown_workers() since the
call queue is no longer working anymore (read and write ends of
the queue pipe are closed).
* terminate_broken() now terminates child processes, not only
wait until they complete.
* _ExecutorManagerThread.terminate_broken() now holds shutdown_lock
to prevent race conditons with ProcessPoolExecutor.submit().
multiprocessing.Queue changes:
* Add _terminate_broken() method.
* _start_thread() sets _thread to None on exception to prevent
leaking "dangling threads" even if the thread was not started
yet.
* Add context manager on Bunch class.
* Bunch now catchs exceptions on executed functions and re-raise them
at __exit__() as an ExceptionGroup.
* Rewrite BarrierProxy.test_default_timeout(). Use a single thread.
Only check that barrier.wait() blocks for at least default timeout
seconds.
* test_with(): inline _with() function.
Fix test_asyncio timeouts: don't measure the maximum duration, a test
should not measure a CI performance. Only measure the minimum
duration when a task has a timeout or delay. Add CLOCK_RES to
test_asyncio.utils.
In the subprocess code path, wait until the child process completes
with a timeout of EXIT_TIMEOUT seconds.
Fix create_worker_process() regression: use start_new_session=True if
USE_PROCESS_GROUP is true.
WorkerThread.wait_stopped() uses a timeout of 60 seconds, instead of
30 seconds.
On Windows, multiprocessing Popen.terminate() now catchs
PermissionError and get the process exit code. If the process is
still running, raise again the PermissionError. Otherwise, the
process terminated as expected: store its exit code.
Fix race conditions in test_threading lock tests. Wait until a
condition is met rather than using time.sleep() with a hardcoded
number of seconds.
* Replace sleeping loops with support.sleeping_retry() which raises
an exception on timeout.
* Add wait_threads_blocked(nthread) which computes a sleep depending
on the number of threads. Remove _wait() function.
* test_set_and_clear(): use a way longer Event.wait() timeout.
* BarrierTests.test_repr(): wait until the 2 threads are waiting for
the barrier. Use a way longer timeout for Barrier.wait() timeout.
* test_thread_leak() no longer needs to count
len(threading.enumerate()): Bunch uses
threading_helper.wait_threads_exit() internally which does it in
wait_for_finished().
* Add BaseLockTests.wait_phase() which implements a timeout.
test_reacquire() and test_recursion_count() use wait_phase().
In 2003, test_pty got a hardcoded timeout of 10 seconds to prevent
hanging on AIX & HPUX "if run after test_openpty":
commit 7d8145268e. Since 2003, test_pty
was no longer reported to hang on AIX. But today, the test can fail
simply because a CI is busy running other tests in parallel.
The timeout of 10 seconds is no longer needed, just remove it.
Moreover, regrtest now has multiple built-in generic timeout
mecanisms.
Fix test_interprocess_signal() of test_signal. Make sure that the
subprocess.Popen object is deleted before the test raising an
exception in a signal handler. Otherwise, Popen.__del__() can get the
exception which is logged as "Exception ignored in: ...." and the
test fails.