Statistics gathering is now off by default. Use the "-X pystats"
command line option or set the new PYTHONSTATS environment variable
to 1 to turn statistics gathering on at Python startup.
Statistics are no longer dumped at exit if statistics gathering was
off or statistics have been cleared.
Changes:
* Add PYTHONSTATS environment variable.
* sys._stats_dump() now returns False if statistics are not dumped
because they are all equal to zero.
* Add PyConfig._pystats member.
* Add tests on sys functions and on setting PyConfig._pystats to 1.
* Add Include/cpython/pystats.h and Include/internal/pycore_pystats.h
header files.
* Rename '_py_stats' variable to '_Py_stats'.
* Exclude Include/cpython/pystats.h from the Py_LIMITED_API.
* Move pystats.h include from object.h to Python.h.
* Add _Py_StatsOn() and _Py_StatsOff() functions. Remove
'_py_stats_struct' variable from the API: make it static in
specialize.c.
* Document API in Include/pystats.h and Include/cpython/pystats.h.
* Complete pystats documentation in Doc/using/configure.rst.
* Don't write "all zeros" stats: if _stats_off() and _stats_clear()
or _stats_dump() were called.
* _PyEval_Fini() now always call _Py_PrintSpecializationStats() which
does nothing if stats are all zeros.
Co-authored-by: Michael Droettboom <mdboom@gmail.com>
Remove the following old functions to configure the Python
initialization, deprecated in Python 3.11:
* PySys_AddWarnOptionUnicode()
* PySys_AddWarnOption()
* PySys_AddXOption()
* PySys_HasWarnOptions()
* PySys_SetArgvEx()
* PySys_SetArgv()
* PySys_SetPath()
* Py_SetPath()
* Py_SetProgramName()
* Py_SetPythonHome()
* Py_SetStandardStreamEncoding()
* _Py_SetProgramFullPath()
Most of these functions are kept in the stable ABI, except:
* Py_SetStandardStreamEncoding()
* _Py_SetProgramFullPath()
Update Doc/extending/embedding.rst and Doc/extending/extending.rst to
use the new PyConfig API.
_testembed.c:
* check_stdio_details() now sets stdio_encoding and stdio_errors
of PyConfig.
* Add definitions of functions removed from the API but kept in the
stable ABI.
* test_init_from_config() and test_init_read_set() now use
PyConfig_SetString() instead of PyConfig_SetBytesString().
Remove _Py_ClearStandardStreamEncoding() internal function.
This is the implementation of PEP683
Motivation:
The PR introduces the ability to immortalize instances in CPython which bypasses reference counting. Tagging objects as immortal allows up to skip certain operations when we know that the object will be around for the entire execution of the runtime.
Note that this by itself will bring a performance regression to the runtime due to the extra reference count checks. However, this brings the ability of having truly immutable objects that are useful in other contexts such as immutable data sharing between sub-interpreters.
* As most of `test_embed` now uses `Py_InitializeFromConfig`, add
a specific test case to cover `Py_Initialize` (and `Py_InitializeEx`)
* Rename `_testembed` init helper to clarify the API used
* Add a `PyConfig_Clear` call in `Py_InitializeEx` to make
the code more obviously correct (it already didn't leak as
none of the dynamically allocated config fields were being
populated, but it's clearer if the wrappers follow the
documented API usage guidelines)
Change FOR_ITER to have the same stack effect regardless of whether it branches or not.
Performance is unchanged as FOR_ITER (and specialized forms jump over the cleanup code).
(see https://github.com/python/cpython/issues/98608)
This change does the following:
1. change the argument to a new `_PyInterpreterConfig` struct
2. rename the function to `_Py_NewInterpreterFromConfig()`, inspired by `Py_InitializeFromConfig()` (takes a `_PyInterpreterConfig` instead of `isolated_subinterpreter`)
3. split up the boolean `isolated_subinterpreter` into the corresponding multiple granular settings
* allow_fork
* allow_subprocess
* allow_threads
4. add `PyInterpreterState.feature_flags` to store those settings
5. add a function for checking if a feature is enabled on an opaque `PyInterpreterState *`
6. drop `PyConfig._isolated_interpreter`
The existing default (see `Py_NewInterpeter()` and `Py_Initialize*()`) allows fork, subprocess, and threads and the optional "isolated" interpreter (see the `_xxsubinterpreters` module) disables all three. None of that changes here; the defaults are preserved.
Note that the given `_PyInterpreterConfig` will not be used outside `_Py_NewInterpreterFromConfig()`, nor preserved. This contrasts with how `PyConfig` is currently preserved, used, and even modified outside `Py_InitializeFromConfig()`. I'd rather just avoid that mess from the start for `_PyInterpreterConfig`. We can preserve it later if we find an actual need.
This change allows us to follow up with a number of improvements (e.g. stop disallowing subprocess and support disallowing exec instead).
(Note that this PR adds "private" symbols. We'll probably make them public, and add docs, in a separate change.)
It had to live as a global outside of PyConfig for stable ABI reasons in
the pre-3.12 backports.
This removes the `_Py_global_config_int_max_str_digits` and gets rid of
the equivalent field in the internal `struct _is PyInterpreterState` as
code can just use the existing nested config struct within that.
Adds tests to verify unique settings and configs in subinterpreters.
Add the -P command line option and the PYTHONSAFEPATH environment
variable to not prepend a potentially unsafe path to sys.path.
* Add sys.flags.safe_path flag.
* Add PyConfig.safe_path member.
* Programs/_bootstrap_python.c uses config.safe_path=0.
* Update subprocess._optim_args_from_interpreter_flags() to handle
the -P command line option.
* Modules/getpath.py sets safe_path to 1 if a "._pth" file is
present.
Use FLAG_REF always for interned strings.
Refcounts of interned string is very unstable.
When compiling same source, refcounts of interned string in the output may be 1 or >1.
It makes FLAG_REF usage unstable.
To help reproducible build, use FLAG_REF for interned string even if refcnt(obj)==1.
* Stores all location info in linetable to conform to PEP 626.
* Remove column table from code objects.
* Remove end-line table from code objects.
* Document new location table format