Add a private list of all stdlib modules: _Py_module_names.
* Add Tools/scripts/generate_module_names.py script.
* Makefile: Add "make regen-module-names" command.
* setup.py: Add --list-module-names option.
* GitHub Action and Travis CI also runs "make regen-module-names",
not ony "make regen-all", to ensure that the module names remains
up to date.
When stdin is a TTY, the test added in commit c13d89955d
is expected to fail. However, when it failed, it did not close
its file descriptors. This is flagged by the refleak tests (but
only when stdin is a TTY, which doesn't seem to be the case on CI).
The Py_FatalError() function and the faulthandler module now dump the
list of extension modules on a fatal error.
Add _Py_DumpExtensionModules() and _PyModule_IsExtension() internal
functions.
When trying to extract the error line for the error message there
are two distinct cases:
1. The input comes from a file, which means that we can extract the
error line by using `PyErr_ProgramTextObject` and which we already
do.
2. The input does not come from a file, at which point we need to get
the source code from the tokenizer:
* If the tokenizer's current line number is the same with the line
of the error, we get the line from `tok->buf` and we're ready.
* Else, we can extract the error line from the source code in the
following two ways:
* If the input comes from a string we have all the input
in `tok->str` and we can extract the error line from it.
* If the input comes from stdin, i.e. the interactive prompt, we
do not have access to the previous line. That's why a new
field `tok->stdin_content` is added which holds the whole input for the
current (multiline) statement or expression. We can then extract the
error line from `tok->stdin_content` like we do in the string case above.
Co-authored-by: Pablo Galindo <Pablogsal@gmail.com>
Before, using the * operator to repeat a bytearray would copy data from the start of
the internal buffer (ob_bytes) and not from the start of the actual data (ob_start).
* Mark bytecodes at end of try-except as artificial.
* Make sure that the CFG is consistent throughout optimiization.
* Extend line-number propagation logic so that implicit returns after 'try-except' or 'with' have the correct line numbers.
* Update importlib
`type.__new__` calls `__set_name__` and `__init_subclass__`, which means
that any work metaclasses do after calling `super().__new__()` will not
be available to those two methods. In particular, `Enum` classes that
want to make use of `__init_subclass__` will not see any members.
Almost all customization is therefore moved to before the
`type.__new__()` call, including changing all members to a proto member
descriptor with a `__set_name__` that will do the final conversion of a
member to be an instance of the `Enum` class.
According to [bpo-42874](), some versions of grep do not support the `-q` and `-E` options. Although both options are used elsewhere in the configure script, this particular bit of validation can be achieved without them,
so there's no real harm in using a grep call with no flags.
Would be good to get some people taking advantage of the `--with-tzpath` arguments in the wild to try this out.. Local testing seems to indicate that this does the same thing, but I don't know that we have any buildbots using this option. Maybe @pablogsal?
[bpo-42874]():
Fix the _PyUnicode_FromId() function (_Py_IDENTIFIER(var) API) when
Py_Initialize() / Py_Finalize() is called multiple times:
preserve _PyRuntime.unicode_ids.next_index value.
Use _PyRuntimeState_INIT macro instead memset(0) to reset
_PyRuntimeState members to zero.
If __repr__ uses instance attributes, as normal, and one steps
through the __init__ method, debugger may try to get repr before
the instance attributes exist. reprlib.repr handles the error.
The distutils bdist_wininst command deprecated in Python 3.8 has been
removed. The distutils bidst_wheel command is now recommended to
distribute binary packages on Windows.
* Remove Lib/distutils/command/bdist_wininst.py
* Remove PC/bdist_wininst/ project
* Remove Lib/distutils/command/wininst-*.exe programs
* Remove all references to bdist_wininst
Convert the 6 CJK codec extension modules (_codecs_cn, _codecs_hk,
_codecs_iso2022, _codecs_jp, _codecs_kr and _codecs_tw) to the
multiphase initialization API (PEP 489).
Remove getmultibytecodec() local cache: always import
_multibytecodec. It should be uncommon to get a codec. For example,
this function is only called once per CJK codec module.
Fix a reference leak in register_maps() error path.
This is only there so that alternative implementations written in statically-typed languages can use this grammar without
having type errors in the way.
Automerge-Triggered-By: GH:lysnikolaou