Each thread specializes a thread-local copy of the bytecode, created on the first RESUME, in free-threaded builds. All copies of the bytecode for a code object are stored in the co_tlbc array on the code object. Threads reserve a globally unique index identifying its copy of the bytecode in all co_tlbc arrays at thread creation and release the index at thread destruction. The first entry in every co_tlbc array always points to the "main" copy of the bytecode that is stored at the end of the code object. This ensures that no bytecode is copied for programs that do not use threads.
Thread-local bytecode can be disabled at runtime by providing either -X tlbc=0 or PYTHON_TLBC=0. Disabling thread-local bytecode also disables specialization.
Concurrent modifications to the bytecode made by the specializing interpreter and instrumentation use atomics, with specialization taking care not to overwrite an instruction that was instrumented concurrently.
This PR adds the ability to enable the GIL if it was disabled at
interpreter startup, and modifies the multi-phase module initialization
path to enable the GIL when loading a module, unless that module's spec
includes a slot indicating it can run safely without the GIL.
PEP 703 called the constant for the slot `Py_mod_gil_not_used`; I went
with `Py_MOD_GIL_NOT_USED` for consistency with gh-104148.
A warning will be issued up to once per interpreter for the first
GIL-using module that is loaded. If `-v` is given, a shorter message
will be printed to stderr every time a GIL-using module is loaded
(including the first one that issues a warning).
The code for Tier 2 is now only compiled when configured
with `--enable-experimental-jit[=yes|interpreter]`.
We drop support for `PYTHON_UOPS` and -`Xuops`,
but you can disable the interpreter or JIT
at runtime by setting `PYTHON_JIT=0`.
You can also build it without enabling it by default
using `--enable-experimental-jit=yes-off`;
enable with `PYTHON_JIT=1`.
On Windows, the `build.bat` script supports
`--experimental-jit`, `--experimental-jit-off`,
`--experimental-interpreter`.
In the C code, `_Py_JIT` is defined as before
when the JIT is enabled; the new variable
`_Py_TIER2` is defined when the JIT *or* the
interpreter is enabled. It is actually a bitmask:
1: JIT; 2: default-off; 4: interpreter.
* Rename _PyUnstable_GetUnaryIntrinsicName() to
PyUnstable_GetUnaryIntrinsicName()
* Rename _PyUnstable_GetBinaryIntrinsicName()
to PyUnstable_GetBinaryIntrinsicName().
* pycore_intrinsics.h does nothing if included twice
(add #ifndef and #define).
* Update Tools/cases_generator/generate_cases.py to generate the
Py_BUILD_CORE test.
* _bz2, _lzma, _opcode and zlib extensions now define the
Py_BUILD_CORE_MODULE macro to use internal headers
(pycore_code.h, pycore_intrinsics.h and pycore_blocks_output_buffer.h).
Here we are doing no more than adding the value for Py_mod_multiple_interpreters and using it for stdlib modules. We will start checking for it in gh-104206 (once PyInterpreterState.ceval.own_gil is added in gh-104204).
"Zero cost" exception handling.
* Uses a lookup table to determine how to handle exceptions.
* Removes SETUP_FINALLY and POP_TOP block instructions, eliminating (most of) the runtime overhead of try statements.
* Reduces the size of the frame object by about 60%.
The new syntax is highly human readable while still preventing false
positives. The syntax also extends Python syntax to denote "self" and
positional-only parameters, allowing inspect.Signature objects to be
totally accurate for all supported builtins in Python 3.4.
annotate text signatures in docstrings, resulting in fewer false
positives. "self" parameters are also explicitly marked, allowing
inspect.Signature() to authoritatively detect (and skip) said parameters.
Issue #20326: Argument Clinic now generates separate checksums for the
input and output sections of the block, allowing external tools to verify
that the input has not changed (and thus the output is not out-of-date).
PyMethodDescr_Type, _PyMethodWrapper_Type, and PyWrapperDescr_Type)
have been modified to provide introspection information for builtins.
Also: many additional Lib, test suite, and Argument Clinic fixes.
* You may now specify an expression as the default value for a
parameter! Example: "sys.maxsize - 1". This support is
intentionally quite limited; you may only use values that
can be represented as static C values.
* Removed "doc_default", simplified support for "c_default"
and "py_default". (I'm not sure we still even need
"py_default", but I'm leaving it in for now in case a
use presents itself.)
* Parameter lines support a trailing '\\' as a line
continuation character, allowing you to break up long lines.
* The argument parsing code generated when supporting optional
groups now uses PyTuple_GET_SIZE instead of PyTuple_GetSize,
leading to a 850% speedup in parsing. (Just kidding, this
is an unmeasurable difference.)
* A bugfix for the recent regression where the generated
prototype from pydoc for builtins would be littered with
unreadable "=<object ...>"" default values for parameters
that had no default value.
* Converted some asserts into proper failure messages.
* Many doc improvements and fixes.