Allow PCbuild\rt.bat to accept unlimited arguments for regrtest.

This makes it possible to pass more than 4 tests by name through
Tools\buildbot\test.bat
This commit is contained in:
Zachary Ware 2015-09-03 23:43:37 -05:00
parent 84368127ed
commit e74fe18ebb
3 changed files with 24 additions and 12 deletions

View File

@ -56,6 +56,12 @@ Documentation
- Issue #22812: Fix unittest discovery examples.
Patch from Pam McA'Nulty.
Tests
-----
- PCbuild\rt.bat now accepts an unlimited number of arguments to pass along
to regrtest.py. Previously there was a limit of 9.
What's New in Python 3.5.0 release candidate 3?
===============================================

View File

@ -32,15 +32,17 @@ set prefix=%pcbuild%win32\
set suffix=
set qmode=
set dashO=
set regrtestargs=
:CheckOpts
if "%1"=="-O" (set dashO=-O) & shift & goto CheckOpts
if "%1"=="-q" (set qmode=yes) & shift & goto CheckOpts
if "%1"=="-d" (set suffix=_d) & shift & goto CheckOpts
if "%1"=="-x64" (set prefix=%pcbuild%amd64\) & shift & goto CheckOpts
if NOT "%1"=="" (set regrtestargs=%regrtestargs% %1) & shift & goto CheckOpts
set exe=%prefix%python%suffix%.exe
set cmd="%exe%" %dashO% -Wd -E -bb "%pcbuild%..\lib\test\regrtest.py" %1 %2 %3 %4 %5 %6 %7 %8 %9
set cmd="%exe%" %dashO% -Wd -E -bb "%pcbuild%..\lib\test\regrtest.py" %regrtestargs%
if defined qmode goto Qmode
echo Deleting .pyc/.pyo files ...

View File

@ -1,15 +1,19 @@
@rem Used by the buildbot "test" step.
@setlocal
@echo off
rem Used by the buildbot "test" step.
setlocal
@set here=%~dp0
@set rt_opts=-q -d
set here=%~dp0
set rt_opts=-q -d
set regrtest_args=
:CheckOpts
@if '%1'=='-x64' (set rt_opts=%rt_opts% %1) & shift & goto CheckOpts
@if '%1'=='-d' (set rt_opts=%rt_opts% %1) & shift & goto CheckOpts
@if '%1'=='-O' (set rt_opts=%rt_opts% %1) & shift & goto CheckOpts
@if '%1'=='-q' (set rt_opts=%rt_opts% %1) & shift & goto CheckOpts
@if '%1'=='+d' (set rt_opts=%rt_opts:-d=%) & shift & goto CheckOpts
@if '%1'=='+q' (set rt_opts=%rt_opts:-q=%) & shift & goto CheckOpts
if "%1"=="-x64" (set rt_opts=%rt_opts% %1) & shift & goto CheckOpts
if "%1"=="-d" (set rt_opts=%rt_opts% %1) & shift & goto CheckOpts
if "%1"=="-O" (set rt_opts=%rt_opts% %1) & shift & goto CheckOpts
if "%1"=="-q" (set rt_opts=%rt_opts% %1) & shift & goto CheckOpts
if "%1"=="+d" (set rt_opts=%rt_opts:-d=%) & shift & goto CheckOpts
if "%1"=="+q" (set rt_opts=%rt_opts:-q=%) & shift & goto CheckOpts
if NOT "%1"=="" (set regrtest_args=%regrtest_args% %1) & shift & goto CheckOpts
call "%here%..\..\PCbuild\rt.bat" %rt_opts% -uall -rwW -n --timeout=3600 %1 %2 %3 %4 %5 %6 %7 %8 %9
echo on
call "%here%..\..\PCbuild\rt.bat" %rt_opts% -uall -rwW -n --timeout=3600 %regrtest_args%