Issue #25593: Change semantics of EventLoop.stop(). (Merge 3.4->3.5)

This commit is contained in:
Guido van Rossum 2015-11-19 13:33:34 -08:00
commit 82f9feaf10
6 changed files with 87 additions and 28 deletions

View File

@ -29,7 +29,16 @@ Run an event loop
.. method:: BaseEventLoop.run_forever()
Run until :meth:`stop` is called.
Run until :meth:`stop` is called. If :meth:`stop` is called before
:meth:`run_forever()` is called, this polls the I/O selector once
with a timeout of zero, runs all callbacks scheduled in response to
I/O events (and those that were already scheduled), and then exits.
If :meth:`stop` is called while :meth:`run_forever` is running,
this will run the current batch of callbacks and then exit. Note
that callbacks scheduled by callbacks will not run in that case;
they will run the next time :meth:`run_forever` is called.
.. versionchanged:: 3.5.1
.. method:: BaseEventLoop.run_until_complete(future)
@ -48,10 +57,10 @@ Run an event loop
Stop running the event loop.
Every callback scheduled before :meth:`stop` is called will run.
Callbacks scheduled after :meth:`stop` is called will not run.
However, those callbacks will run if :meth:`run_forever` is called
again later.
This causes :meth:`run_forever` to exit at the next suitable
opportunity (see there for more details).
.. versionchanged:: 3.5.1
.. method:: BaseEventLoop.is_closed()
@ -61,7 +70,8 @@ Run an event loop
.. method:: BaseEventLoop.close()
Close the event loop. The loop must not be running.
Close the event loop. The loop must not be running. Pending
callbacks will be lost.
This clears the queues and shuts down the executor, but does not wait for
the executor to finish.

View File

@ -494,7 +494,7 @@ data and wait until the connection is closed::
def connection_lost(self, exc):
print('The server closed the connection')
print('Stop the event lop')
print('Stop the event loop')
self.loop.stop()
loop = asyncio.get_event_loop()

View File

@ -70,10 +70,6 @@ def _format_pipe(fd):
return repr(fd)
class _StopError(BaseException):
"""Raised to stop the event loop."""
def _check_resolved_address(sock, address):
# Ensure that the address is already resolved to avoid the trap of hanging
# the entire event loop when the address requires doing a DNS lookup.
@ -118,9 +114,6 @@ def _check_resolved_address(sock, address):
"got host %r: %s"
% (host, err))
def _raise_stop_error(*args):
raise _StopError
def _run_until_complete_cb(fut):
exc = fut._exception
@ -129,7 +122,7 @@ def _run_until_complete_cb(fut):
# Issue #22429: run_forever() already finished, no need to
# stop it.
return
_raise_stop_error()
fut._loop.stop()
class Server(events.AbstractServer):
@ -184,6 +177,7 @@ class BaseEventLoop(events.AbstractEventLoop):
def __init__(self):
self._timer_cancelled_count = 0
self._closed = False
self._stopping = False
self._ready = collections.deque()
self._scheduled = []
self._default_executor = None
@ -298,11 +292,11 @@ class BaseEventLoop(events.AbstractEventLoop):
self._thread_id = threading.get_ident()
try:
while True:
try:
self._run_once()
except _StopError:
self._run_once()
if self._stopping:
break
finally:
self._stopping = False
self._thread_id = None
self._set_coroutine_wrapper(False)
@ -345,11 +339,10 @@ class BaseEventLoop(events.AbstractEventLoop):
def stop(self):
"""Stop running the event loop.
Every callback scheduled before stop() is called will run. Callbacks
scheduled after stop() is called will not run. However, those callbacks
will run if run_forever is called again later.
Every callback already scheduled will still run. This simply informs
run_forever to stop looping after a complete iteration.
"""
self.call_soon(_raise_stop_error)
self._stopping = True
def close(self):
"""Close the event loop.
@ -1194,7 +1187,7 @@ class BaseEventLoop(events.AbstractEventLoop):
handle._scheduled = False
timeout = None
if self._ready:
if self._ready or self._stopping:
timeout = 0
elif self._scheduled:
# Compute the desired timeout.

View File

@ -71,12 +71,13 @@ def run_until(loop, pred, timeout=30):
def run_once(loop):
"""loop.stop() schedules _raise_stop_error()
and run_forever() runs until _raise_stop_error() callback.
this wont work if test waits for some IO events, because
_raise_stop_error() runs before any of io events callbacks.
"""Legacy API to run once through the event loop.
This is the recommended pattern for test code. It will poll the
selector once and run all callbacks scheduled in response to I/O
events.
"""
loop.stop()
loop.call_soon(loop.stop)
loop.run_forever()

View File

@ -757,6 +757,59 @@ class BaseEventLoopTests(test_utils.TestCase):
pass
self.assertTrue(func.called)
def test_single_selecter_event_callback_after_stopping(self):
# Python issue #25593: A stopped event loop may cause event callbacks
# to run more than once.
event_sentinel = object()
callcount = 0
doer = None
def proc_events(event_list):
nonlocal doer
if event_sentinel in event_list:
doer = self.loop.call_soon(do_event)
def do_event():
nonlocal callcount
callcount += 1
self.loop.call_soon(clear_selector)
def clear_selector():
doer.cancel()
self.loop._selector.select.return_value = ()
self.loop._process_events = proc_events
self.loop._selector.select.return_value = (event_sentinel,)
for i in range(1, 3):
with self.subTest('Loop %d/2' % i):
self.loop.call_soon(self.loop.stop)
self.loop.run_forever()
self.assertEqual(callcount, 1)
def test_run_once(self):
# Simple test for test_utils.run_once(). It may seem strange
# to have a test for this (the function isn't even used!) but
# it's a de-factor standard API for library tests. This tests
# the idiom: loop.call_soon(loop.stop); loop.run_forever().
count = 0
def callback():
nonlocal count
count += 1
self.loop._process_events = mock.Mock()
self.loop.call_soon(callback)
test_utils.run_once(self.loop)
self.assertEqual(count, 1)
def test_run_forever_pre_stopped(self):
# Test that the old idiom for pre-stopping the loop works.
self.loop._process_events = mock.Mock()
self.loop.stop()
self.loop.run_forever()
self.loop._selector.select.assert_called_once_with(0)
class MyProto(asyncio.Protocol):
done = None

View File

@ -77,6 +77,8 @@ Core and Builtins
Library
-------
- Issue #25593: Change semantics of EventLoop.stop() in asyncio.
- Issue #6973: When we know a subprocess.Popen process has died, do
not allow the send_signal(), terminate(), or kill() methods to do
anything as they could potentially signal a different process.