gh-116750: Add clear_tool_id function to unregister events and callbacks (#124568)

This commit is contained in:
Tian Gao 2024-10-01 10:32:55 -07:00 committed by GitHub
parent b482538523
commit 5e0abb4788
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194
8 changed files with 165 additions and 8 deletions

View File

@ -50,16 +50,14 @@ Registering and using tools
*tool_id* must be in the range 0 to 5 inclusive. *tool_id* must be in the range 0 to 5 inclusive.
Raises a :exc:`ValueError` if *tool_id* is in use. Raises a :exc:`ValueError` if *tool_id* is in use.
.. function:: clear_tool_id(tool_id: int, /) -> None
Unregister all events and callback functions associated with *tool_id*.
.. function:: free_tool_id(tool_id: int, /) -> None .. function:: free_tool_id(tool_id: int, /) -> None
Should be called once a tool no longer requires *tool_id*. Should be called once a tool no longer requires *tool_id*.
Will call :func:`clear_tool_id` before releasing *tool_id*.
.. note::
:func:`free_tool_id` will not disable global or local events associated
with *tool_id*, nor will it unregister any callback functions. This
function is only intended to be used to notify the VM that the
particular *tool_id* is no longer in use.
.. function:: get_tool(tool_id: int, /) -> str | None .. function:: get_tool(tool_id: int, /) -> str | None

View File

@ -8,6 +8,8 @@
extern "C" { extern "C" {
#endif #endif
/* Total tool ids available */
#define _PY_MONITORING_TOOL_IDS 8
/* Count of all local monitoring events */ /* Count of all local monitoring events */
#define _PY_MONITORING_LOCAL_EVENTS 10 #define _PY_MONITORING_LOCAL_EVENTS 10
/* Count of all "real" monitoring events (not derived from other events) */ /* Count of all "real" monitoring events (not derived from other events) */
@ -57,6 +59,8 @@ typedef struct {
_Py_LocalMonitors active_monitors; _Py_LocalMonitors active_monitors;
/* The tools that are to be notified for events for the matching code unit */ /* The tools that are to be notified for events for the matching code unit */
uint8_t *tools; uint8_t *tools;
/* The version of tools when they instrument the code */
uintptr_t tool_versions[_PY_MONITORING_TOOL_IDS];
/* Information to support line events */ /* Information to support line events */
_PyCoLineInstrumentationData *lines; _PyCoLineInstrumentationData *lines;
/* The tools that are to be notified for line events for the matching code unit */ /* The tools that are to be notified for line events for the matching code unit */

View File

@ -272,6 +272,7 @@ struct _is {
Py_ssize_t sys_tracing_threads; /* Count of threads with c_tracefunc set */ Py_ssize_t sys_tracing_threads; /* Count of threads with c_tracefunc set */
PyObject *monitoring_callables[PY_MONITORING_TOOL_IDS][_PY_MONITORING_EVENTS]; PyObject *monitoring_callables[PY_MONITORING_TOOL_IDS][_PY_MONITORING_EVENTS];
PyObject *monitoring_tool_names[PY_MONITORING_TOOL_IDS]; PyObject *monitoring_tool_names[PY_MONITORING_TOOL_IDS];
uintptr_t monitoring_tool_versions[PY_MONITORING_TOOL_IDS];
struct _Py_interp_cached_objects cached_objects; struct _Py_interp_cached_objects cached_objects;
struct _Py_interp_static_objects static_objects; struct _Py_interp_static_objects static_objects;

View File

@ -46,10 +46,14 @@ def nth_line(func, offset):
class MonitoringBasicTest(unittest.TestCase): class MonitoringBasicTest(unittest.TestCase):
def tearDown(self):
sys.monitoring.free_tool_id(TEST_TOOL)
def test_has_objects(self): def test_has_objects(self):
m = sys.monitoring m = sys.monitoring
m.events m.events
m.use_tool_id m.use_tool_id
m.clear_tool_id
m.free_tool_id m.free_tool_id
m.get_tool m.get_tool
m.get_events m.get_events
@ -77,6 +81,43 @@ class MonitoringBasicTest(unittest.TestCase):
with self.assertRaises(ValueError): with self.assertRaises(ValueError):
sys.monitoring.set_events(TEST_TOOL, sys.monitoring.events.CALL) sys.monitoring.set_events(TEST_TOOL, sys.monitoring.events.CALL)
def test_clear(self):
events = []
sys.monitoring.use_tool_id(TEST_TOOL, "MonitoringTest.Tool")
sys.monitoring.register_callback(TEST_TOOL, E.PY_START, lambda *args: events.append(args))
sys.monitoring.register_callback(TEST_TOOL, E.LINE, lambda *args: events.append(args))
def f():
a = 1
sys.monitoring.set_local_events(TEST_TOOL, f.__code__, E.LINE)
sys.monitoring.set_events(TEST_TOOL, E.PY_START)
f()
sys.monitoring.clear_tool_id(TEST_TOOL)
f()
# the first f() should trigger a PY_START and a LINE event
# the second f() after clear_tool_id should not trigger any event
# the callback function should be cleared as well
self.assertEqual(len(events), 2)
callback = sys.monitoring.register_callback(TEST_TOOL, E.LINE, None)
self.assertIs(callback, None)
sys.monitoring.free_tool_id(TEST_TOOL)
events = []
sys.monitoring.use_tool_id(TEST_TOOL, "MonitoringTest.Tool")
sys.monitoring.register_callback(TEST_TOOL, E.LINE, lambda *args: events.append(args))
sys.monitoring.set_local_events(TEST_TOOL, f.__code__, E.LINE)
f()
sys.monitoring.free_tool_id(TEST_TOOL)
sys.monitoring.use_tool_id(TEST_TOOL, "MonitoringTest.Tool")
f()
# the first f() should trigger a LINE event, and even if we use the
# tool id immediately after freeing it, the second f() should not
# trigger any event
self.assertEqual(len(events), 1)
sys.monitoring.free_tool_id(TEST_TOOL)
class MonitoringTestBase: class MonitoringTestBase:

View File

@ -0,0 +1 @@
Provide :func:`sys.monitoring.clear_tool_id` to unregister all events and callbacks set by the tool.

View File

@ -36,6 +36,33 @@ exit:
return return_value; return return_value;
} }
PyDoc_STRVAR(monitoring_clear_tool_id__doc__,
"clear_tool_id($module, tool_id, /)\n"
"--\n"
"\n");
#define MONITORING_CLEAR_TOOL_ID_METHODDEF \
{"clear_tool_id", (PyCFunction)monitoring_clear_tool_id, METH_O, monitoring_clear_tool_id__doc__},
static PyObject *
monitoring_clear_tool_id_impl(PyObject *module, int tool_id);
static PyObject *
monitoring_clear_tool_id(PyObject *module, PyObject *arg)
{
PyObject *return_value = NULL;
int tool_id;
tool_id = PyLong_AsInt(arg);
if (tool_id == -1 && PyErr_Occurred()) {
goto exit;
}
return_value = monitoring_clear_tool_id_impl(module, tool_id);
exit:
return return_value;
}
PyDoc_STRVAR(monitoring_free_tool_id__doc__, PyDoc_STRVAR(monitoring_free_tool_id__doc__,
"free_tool_id($module, tool_id, /)\n" "free_tool_id($module, tool_id, /)\n"
"--\n" "--\n"
@ -304,4 +331,4 @@ monitoring__all_events(PyObject *module, PyObject *Py_UNUSED(ignored))
{ {
return monitoring__all_events_impl(module); return monitoring__all_events_impl(module);
} }
/*[clinic end generated code: output=14ffc0884a6de50a input=a9049054013a1b77]*/ /*[clinic end generated code: output=8f81876c6aba9be8 input=a9049054013a1b77]*/

View File

@ -1660,6 +1660,16 @@ update_instrumentation_data(PyCodeObject *code, PyInterpreterState *interp)
if (allocate_instrumentation_data(code)) { if (allocate_instrumentation_data(code)) {
return -1; return -1;
} }
// If the local monitors are out of date, clear them up
_Py_LocalMonitors *local_monitors = &code->_co_monitoring->local_monitors;
for (int i = 0; i < PY_MONITORING_TOOL_IDS; i++) {
if (code->_co_monitoring->tool_versions[i] != interp->monitoring_tool_versions[i]) {
for (int j = 0; j < _PY_MONITORING_LOCAL_EVENTS; j++) {
local_monitors->tools[j] &= ~(1 << i);
}
}
}
_Py_LocalMonitors all_events = local_union( _Py_LocalMonitors all_events = local_union(
interp->monitors, interp->monitors,
code->_co_monitoring->local_monitors); code->_co_monitoring->local_monitors);
@ -2004,6 +2014,8 @@ _PyMonitoring_SetLocalEvents(PyCodeObject *code, int tool_id, _PyMonitoringEvent
goto done; goto done;
} }
code->_co_monitoring->tool_versions[tool_id] = interp->monitoring_tool_versions[tool_id];
_Py_LocalMonitors *local = &code->_co_monitoring->local_monitors; _Py_LocalMonitors *local = &code->_co_monitoring->local_monitors;
uint32_t existing_events = get_local_events(local, tool_id); uint32_t existing_events = get_local_events(local, tool_id);
if (existing_events == events) { if (existing_events == events) {
@ -2036,6 +2048,43 @@ _PyMonitoring_GetLocalEvents(PyCodeObject *code, int tool_id, _PyMonitoringEvent
return 0; return 0;
} }
int _PyMonitoring_ClearToolId(int tool_id)
{
assert(0 <= tool_id && tool_id < PY_MONITORING_TOOL_IDS);
PyInterpreterState *interp = _PyInterpreterState_GET();
for (int i = 0; i < _PY_MONITORING_EVENTS; i++) {
PyObject *func = _PyMonitoring_RegisterCallback(tool_id, i, NULL);
if (func != NULL) {
Py_DECREF(func);
}
}
if (_PyMonitoring_SetEvents(tool_id, 0) < 0) {
return -1;
}
_PyEval_StopTheWorld(interp);
uint32_t version = global_version(interp) + MONITORING_VERSION_INCREMENT;
if (version == 0) {
PyErr_Format(PyExc_OverflowError, "events set too many times");
_PyEval_StartTheWorld(interp);
return -1;
}
// monitoring_tool_versions[tool_id] is set to latest global version here to
// 1. invalidate local events on all existing code objects
// 2. be ready for the next call to set local events
interp->monitoring_tool_versions[tool_id] = version;
// Set the new global version so all the code objects can refresh the
// instrumentation.
set_global_version(_PyThreadState_GET(), version);
int res = instrument_all_executing_code_objects(interp);
_PyEval_StartTheWorld(interp);
return res;
}
/*[clinic input] /*[clinic input]
module monitoring module monitoring
[clinic start generated code]*/ [clinic start generated code]*/
@ -2083,6 +2132,33 @@ monitoring_use_tool_id_impl(PyObject *module, int tool_id, PyObject *name)
Py_RETURN_NONE; Py_RETURN_NONE;
} }
/*[clinic input]
monitoring.clear_tool_id
tool_id: int
/
[clinic start generated code]*/
static PyObject *
monitoring_clear_tool_id_impl(PyObject *module, int tool_id)
/*[clinic end generated code: output=04defc23470b1be7 input=af643d6648a66163]*/
{
if (check_valid_tool(tool_id)) {
return NULL;
}
PyInterpreterState *interp = _PyInterpreterState_GET();
if (interp->monitoring_tool_names[tool_id] != NULL) {
if (_PyMonitoring_ClearToolId(tool_id) < 0) {
return NULL;
}
}
Py_RETURN_NONE;
}
/*[clinic input] /*[clinic input]
monitoring.free_tool_id monitoring.free_tool_id
@ -2099,6 +2175,13 @@ monitoring_free_tool_id_impl(PyObject *module, int tool_id)
return NULL; return NULL;
} }
PyInterpreterState *interp = _PyInterpreterState_GET(); PyInterpreterState *interp = _PyInterpreterState_GET();
if (interp->monitoring_tool_names[tool_id] != NULL) {
if (_PyMonitoring_ClearToolId(tool_id) < 0) {
return NULL;
}
}
Py_CLEAR(interp->monitoring_tool_names[tool_id]); Py_CLEAR(interp->monitoring_tool_names[tool_id]);
Py_RETURN_NONE; Py_RETURN_NONE;
} }
@ -2376,6 +2459,7 @@ monitoring__all_events_impl(PyObject *module)
static PyMethodDef methods[] = { static PyMethodDef methods[] = {
MONITORING_USE_TOOL_ID_METHODDEF MONITORING_USE_TOOL_ID_METHODDEF
MONITORING_CLEAR_TOOL_ID_METHODDEF
MONITORING_FREE_TOOL_ID_METHODDEF MONITORING_FREE_TOOL_ID_METHODDEF
MONITORING_GET_TOOL_METHODDEF MONITORING_GET_TOOL_METHODDEF
MONITORING_REGISTER_CALLBACK_METHODDEF MONITORING_REGISTER_CALLBACK_METHODDEF

View File

@ -654,6 +654,7 @@ init_interpreter(PyInterpreterState *interp,
interp->monitoring_callables[t][e] = NULL; interp->monitoring_callables[t][e] = NULL;
} }
interp->monitoring_tool_versions[t] = 0;
} }
interp->sys_profile_initialized = false; interp->sys_profile_initialized = false;
interp->sys_trace_initialized = false; interp->sys_trace_initialized = false;