ardupilot/libraries/AP_Logger
Jaaaky 1817280e01 AP_Logger: fix 'last_file' may be used uninitialized with debug build 2020-01-06 14:53:03 +11:00
..
examples AP_Logger: correct Write() containing 'a' entries 2019-12-11 15:50:42 +11:00
AP_Logger.cpp AP_Logger: mavlink backend needs to be the last backend 2020-01-02 18:18:04 +11:00
AP_Logger.h AP_Logger: added CESC message for logging CAN ESC status 2020-01-05 15:25:56 +11:00
AP_Logger_Backend.cpp AP_Logger: correct Write() containing 'a' entries 2019-12-11 15:50:42 +11:00
AP_Logger_Backend.h AP_Logger: Support new ModeReason 2019-10-25 08:48:22 +08:00
AP_Logger_Block.cpp AP_Logger: fix 'last_file' may be used uninitialized with debug build 2020-01-06 14:53:03 +11:00
AP_Logger_Block.h AP_Logger: mavlink backend needs to be the last backend 2020-01-02 18:18:04 +11:00
AP_Logger_DataFlash.cpp AP_Logger: mavlink backend needs to be the last backend 2020-01-02 18:18:04 +11:00
AP_Logger_DataFlash.h AP_Logger: mavlink backend needs to be the last backend 2020-01-02 18:18:04 +11:00
AP_Logger_File.cpp AP_Logger: fixed LOG_FILE_DSRMROT with delayed log stop 2019-10-03 07:17:16 +10:00
AP_Logger_File.h AP_Logger: fixed LOG_FILE_DSRMROT with delayed log stop 2019-10-03 07:17:16 +10:00
AP_Logger_MAVLink.cpp AP_Logger: fixed use of old irqsave() API 2019-09-21 15:36:47 +10:00
AP_Logger_MAVLink.h AP_Logger: pass mavlink_message_t by const reference 2019-07-16 20:51:42 +10:00
AP_Logger_MAVLinkLogTransfer.cpp AP_Logger: mavlink backend needs to be the last backend 2020-01-02 18:18:04 +11:00
AP_Logger_SITL.cpp AP_Logger: mavlink backend needs to be the last backend 2020-01-02 18:18:04 +11:00
AP_Logger_SITL.h AP_Logger: mavlink backend needs to be the last backend 2020-01-02 18:18:04 +11:00
LogFile.cpp AP_Logger: added CESC message for logging CAN ESC status 2020-01-05 15:25:56 +11:00
LogStructure.h AP_Logger: added CESC message for logging CAN ESC status 2020-01-05 15:25:56 +11:00
LoggerMessageWriter.cpp AP_Logger: tidy MessageWriter stages using enum class 2019-10-05 16:37:43 +10:00
LoggerMessageWriter.h AP_Logger: tidy MessageWriter stages using enum class 2019-10-05 16:37:43 +10:00
README.md AP_Logger: add a README.md to help locating units/mults/fieldtypes 2019-06-04 19:00:11 +10:00

README.md

Logger Notes

Format Types

The format type specifies the amount of storage required for the entry and how the content should be interpreted.

Char C Type
a int16_t[32]
b int8_t
B uint8_t
h int16_t
H uint16_t
i int32_t
I uint32_t
f float
d double
n char[4]
N char[16]
Z char[64]
L int32_t latitude/longitude (so -35.1332423 becomes -351332423)
M uint8_t flight mode
q int64_t
Q uint64_t

Legacy field types - do not use. These have been replaced by using the base C type and an appropriate multiplier column entry.

Char CType+Mult
c int16_t * 100
C uint16_t * 100
e int32_t * 100
E uint32_t * 100

Units

All units here should be base units This does mean battery capacity is here as "amp*second" Please keep the names consistent with Tools/autotest/param_metadata/param.py:33

Char Unit Abbrev. Description
'-' "" no units e.g. Pi
'?' "UNKNOWN" Units which haven't been worked out yet....
'A' "A" Ampere
'd' "deg" of the angular variety
'b' "B" bytes
'k' "deg/s" degrees per second. Degrees are NOT SI
'D' "deglatitude" degrees of latitude
'e' "deg/s/s" degrees per second per second. Degrees are NOT SI
'E' "rad/s" radians per second
'G' "Gauss" Gauss is not an SI unit
'h' "degheading" 0.? to 359.?
'i' "A.s" Ampere second
'J' "W.s" Joule (Watt second)
'l' "l" litres
'L' "rad/s/s" radians per second per second
'm' "m" metres
'n' "m/s" metres per second
'N' "N" Newton
'o' "m/s/s" metres per second per second
'O' "degC" degrees Celsius. Not SI
'%' "%" percent
'S' "satellites" number of satellites
's' "s" seconds
'q' "rpm" rounds per minute. Not SI
'r' "rad" radians
'U' "deglongitude" degrees of longitude
'u' "ppm" pulses per minute
'v' "V" Volt
'P' "Pa" Pascal
'w' "Ohm" Ohm
'Y' "us" pulse width modulation in microseconds
'z' "Hz" Hertz
'#' "instance" (e.g.)Sensor instance number

Multipliers

This multiplier information applies to the raw value present in the log. Any adjustment implied by the format field (e.g. the "centi" in "centidegrees" is IGNORED for the purposes of scaling. Essentially "format" simply tells you the C-type, and format-type h (int16_t) is equivalent to format-type c (int16_t*100) tl;dr a GCS shouldn't/mustn't infer any scaling from the unit name

Char Multiplier
'-' 0
'?' 1
'2' 1e2
'1' 1e1
'0' 1e0
'A' 1e-1
'B' 1e-2
'C' 1e-3
'D' 1e-4
'E' 1e-5
'F' 1e-6
'G' 1e-7
'!' 3.6
'/' 3600