ardupilot/libraries/AP_BattMonitor/AP_BattMonitor_Logging.cpp

92 lines
3.1 KiB
C++

#include <AP_Logger/AP_Logger_config.h>
#if HAL_LOGGING_ENABLED
#include "AP_BattMonitor_Backend.h"
#include <AP_Logger/AP_Logger.h>
extern const AP_HAL::HAL& hal;
// Write BAT data packet(s)
void AP_BattMonitor_Backend::Log_Write_BAT(const uint8_t instance, const uint64_t time_us) const
{
bool has_curr = has_current();
uint8_t percent = -1;
IGNORE_RETURN(capacity_remaining_pct(percent));
float temperature;
int16_t temperature_cd = 0;
if (get_temperature(temperature)) {
temperature_cd = temperature * 100.0;
}
uint8_t soh_pct = 0;
IGNORE_RETURN(get_state_of_health_pct(soh_pct));
const struct log_BAT pkt{
LOG_PACKET_HEADER_INIT(LOG_BAT_MSG),
time_us : time_us,
instance : instance,
voltage : _state.voltage,
voltage_resting : _state.voltage_resting_estimate,
current_amps : has_curr ? _state.current_amps : AP::logger().quiet_nanf(),
current_total : has_curr ? _state.consumed_mah : AP::logger().quiet_nanf(),
consumed_wh : has_curr ? _state.consumed_wh : AP::logger().quiet_nanf(),
temperature : temperature_cd,
resistance : _state.resistance,
rem_percent : percent,
health : _state.healthy,
state_of_health_pct : soh_pct
};
AP::logger().WriteBlock(&pkt, sizeof(pkt));
}
// Write BCL data packet if has_cell_voltages
void AP_BattMonitor_Backend::Log_Write_BCL(const uint8_t instance, const uint64_t time_us) const
{
if (!has_cell_voltages()) {
return;
}
struct log_BCL cell_pkt{
LOG_PACKET_HEADER_INIT(LOG_BCL_MSG),
time_us : time_us,
instance : instance,
voltage : _state.voltage
};
// we pack the entire BCL message - we must have at least that
// many supported cells or the loop below will over-read
static_assert(ARRAY_SIZE(_state.cell_voltages.cells) >= ARRAY_SIZE(cell_pkt.cell_voltages), "must have at least ARRAY_SIZE(log_BCL.cell_voltages) cells");
for (uint8_t i = 0; i < ARRAY_SIZE(cell_pkt.cell_voltages); i++) {
cell_pkt.cell_voltages[i] = _state.cell_voltages.cells[i] + 1; // add 1mv
}
AP::logger().WriteBlock(&cell_pkt, sizeof(cell_pkt));
#if AP_BATT_MONITOR_CELLS_MAX > 12
if (_state.cell_voltages.cells[12] != UINT16_MAX || _state.cell_voltages.cells[13] != UINT16_MAX)
{
// @LoggerMessage: BCL2
// @Description: Battery cell voltage information
// @Field: TimeUS: Time since system startup
// @Field: Instance: battery instance number
// @Field: V13: thirteenth cell voltage
// @Field: V14: fourteenth cell voltage
AP::logger().WriteStreaming(
"BCL2",
"TimeUS,Instance,V13,V14",
"s#vv",
"F-CC",
"QBHH",
time_us,
instance,
_state.cell_voltages.cells[ARRAY_SIZE(cell_pkt.cell_voltages)+0] + 1, // add 1mv
_state.cell_voltages.cells[ARRAY_SIZE(cell_pkt.cell_voltages)+1] + 1 // add 1mv
);
}
#endif
}
#endif // HAL_LOGGING_ENABLED