#include <AP_Common/AP_Common.h>
|
|
#include <AP_Vehicle/AP_Vehicle_Type.h>
|
|
#include "AP_BattMonitor_Params.h"
|
|
#include "AP_BattMonitor_Analog.h"
|
|
|
|
#if APM_BUILD_TYPE(APM_BUILD_ArduCopter)
|
|
#define DEFAULT_LOW_BATTERY_VOLTAGE 10.5f
|
|
#else
|
|
#define DEFAULT_LOW_BATTERY_VOLTAGE 0.0f
|
|
#endif // APM_BUILD_TYPE(APM_BUILD_ArduCopter)
|
|
|
|
const AP_Param::GroupInfo AP_BattMonitor_Params::var_info[] = {
|
|
// @Param: MONITOR
|
|
// @DisplayName: Battery monitoring
|
|
// @Description: Controls enabling monitoring of the battery's voltage and current
|
|
// @Values: 0:Disabled,3:Analog Voltage Only,4:Analog Voltage and Current,5:Solo,6:Bebop,7:SMBus-Maxell,8:UAVCAN-BatteryInfo,9:BLHeli ESC,10:SumOfFollowing,11:FuelFlow
|
|
// @User: Standard
|
|
// @RebootRequired: True
|
|
AP_GROUPINFO_FLAGS("MONITOR", 1, AP_BattMonitor_Params, _type, BattMonitor_TYPE_NONE, AP_PARAM_FLAG_ENABLE),
|
|
|
|
// @Param: VOLT_PIN
|
|
// @DisplayName: Battery Voltage sensing pin
|
|
// @Description: Sets the analog input pin that should be used for voltage monitoring.
|
|
// @Values: -1:Disabled, 2:Pixhawk/Pixracer/Navio2/Pixhawk2_PM1, 13:Pixhawk2_PM2, 100:PX4-v1
|
|
// @User: Standard
|
|
// @RebootRequired: True
|
|
AP_GROUPINFO("VOLT_PIN", 2, AP_BattMonitor_Params, _volt_pin, AP_BATT_VOLT_PIN),
|
|
|
|
// @Param: CURR_PIN
|
|
// @DisplayName: Battery Current sensing pin
|
|
// @Description: Sets the analog input pin that should be used for current monitoring.
|
|
// @Values: -1:Disabled, 3:Pixhawk/Pixracer/Navio2/Pixhawk2_PM1, 14:Pixhawk2_PM2, 101:PX4-v1
|
|
// @User: Standard
|
|
// @RebootRequired: True
|
|
AP_GROUPINFO("CURR_PIN", 3, AP_BattMonitor_Params, _curr_pin, AP_BATT_CURR_PIN),
|
|
|
|
// @Param: VOLT_MULT
|
|
// @DisplayName: Voltage Multiplier
|
|
// @Description: Used to convert the voltage of the voltage sensing pin (@PREFIX@VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.
|
|
// @User: Advanced
|
|
AP_GROUPINFO("VOLT_MULT", 4, AP_BattMonitor_Params, _volt_multiplier, AP_BATT_VOLTDIVIDER_DEFAULT),
|
|
|
|
// @Param: AMP_PERVLT
|
|
// @DisplayName: Amps per volt
|
|
// @Description: Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17.
|
|
// @Units: A/V
|
|
// @User: Standard
|
|
AP_GROUPINFO("AMP_PERVLT", 5, AP_BattMonitor_Params, _curr_amp_per_volt, AP_BATT_CURR_AMP_PERVOLT_DEFAULT),
|
|
|
|
// @Param: AMP_OFFSET
|
|
// @DisplayName: AMP offset
|
|
// @Description: Voltage offset at zero current on current sensor
|
|
// @Units: V
|
|
// @User: Standard
|
|
AP_GROUPINFO("AMP_OFFSET", 6, AP_BattMonitor_Params, _curr_amp_offset, 0),
|
|
|
|
// @Param: CAPACITY
|
|
// @DisplayName: Battery capacity
|
|
// @Description: Capacity of the battery in mAh when full
|
|
// @Units: mAh
|
|
// @Increment: 50
|
|
// @User: Standard
|
|
AP_GROUPINFO("CAPACITY", 7, AP_BattMonitor_Params, _pack_capacity, 3300),
|
|
|
|
// @Param: WATT_MAX
|
|
// @DisplayName: Maximum allowed power (Watts)
|
|
// @Description: If battery wattage (voltage * current) exceeds this value then the system will reduce max throttle (THR_MAX, TKOFF_THR_MAX and THR_MIN for reverse thrust) to satisfy this limit. This helps limit high current to low C rated batteries regardless of battery voltage. The max throttle will slowly grow back to THR_MAX (or TKOFF_THR_MAX ) and THR_MIN if demanding the current max and under the watt max. Use 0 to disable.
|
|
// @Units: W
|
|
// @Increment: 1
|
|
// @User: Advanced
|
|
AP_GROUPINFO_FRAME("WATT_MAX", 8, AP_BattMonitor_Params, _watt_max, 0, AP_PARAM_FRAME_PLANE),
|
|
|
|
// @Param: SERIAL_NUM
|
|
// @DisplayName: Battery serial number
|
|
// @Description: Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With UAVCAN it is the battery_id.
|
|
// @User: Advanced
|
|
AP_GROUPINFO("SERIAL_NUM", 9, AP_BattMonitor_Params, _serial_number, AP_BATT_SERIAL_NUMBER_DEFAULT),
|
|
|
|
// @Param: LOW_TIMER
|
|
// @DisplayName: Low voltage timeout
|
|
// @Description: This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.
|
|
// @Units: s
|
|
// @Increment: 1
|
|
// @Range: 0 120
|
|
// @User: Advanced
|
|
AP_GROUPINFO("LOW_TIMER", 10, AP_BattMonitor_Params, _low_voltage_timeout, 10),
|
|
|
|
// @Param: FS_VOLTSRC
|
|
// @DisplayName: Failsafe voltage source
|
|
// @Description: Voltage type used for detection of low voltage event
|
|
// @Values: 0:Raw Voltage, 1:Sag Compensated Voltage
|
|
// @User: Advanced
|
|
AP_GROUPINFO("FS_VOLTSRC", 11, AP_BattMonitor_Params, _failsafe_voltage_source, BattMonitor_LowVoltageSource_Raw),
|
|
|
|
// @Param: LOW_VOLT
|
|
// @DisplayName: Low battery voltage
|
|
// @Description: Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the @PREFIX@LOW_TIMER parameter then the vehicle will perform the failsafe specified by the @PREFIX@FS_LOW_ACT parameter.
|
|
// @Units: V
|
|
// @Increment: 0.1
|
|
// @User: Standard
|
|
AP_GROUPINFO("LOW_VOLT", 12, AP_BattMonitor_Params, _low_voltage, DEFAULT_LOW_BATTERY_VOLTAGE),
|
|
|
|
// @Param: LOW_MAH
|
|
// @DisplayName: Low battery capacity
|
|
// @Description: Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the @PREFIX@FS_LOW_ACT parameter.
|
|
// @Units: mAh
|
|
// @Increment: 50
|
|
// @User: Standard
|
|
AP_GROUPINFO("LOW_MAH", 13, AP_BattMonitor_Params, _low_capacity, 0),
|
|
|
|
// @Param: CRT_VOLT
|
|
// @DisplayName: Critical battery voltage
|
|
// @Description: Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the @PREFIX@LOW_TIMER parameter then the vehicle will perform the failsafe specified by the @PREFIX@FS_CRT_ACT parameter.
|
|
// @Units: V
|
|
// @Increment: 0.1
|
|
// @User: Standard
|
|
AP_GROUPINFO("CRT_VOLT", 14, AP_BattMonitor_Params, _critical_voltage, 0),
|
|
|
|
// @Param: CRT_MAH
|
|
// @DisplayName: Battery critical capacity
|
|
// @Description: Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the @PREFIX@_FS_CRT_ACT parameter.
|
|
// @Units: mAh
|
|
// @Increment: 50
|
|
// @User: Standard
|
|
AP_GROUPINFO("CRT_MAH", 15, AP_BattMonitor_Params, _critical_capacity, 0),
|
|
|
|
// @Param: FS_LOW_ACT
|
|
// @DisplayName: Low battery failsafe action
|
|
// @Description: What action the vehicle should perform if it hits a low battery failsafe
|
|
// @Values{Plane}: 0:None,1:RTL,2:Land,3:Terminate,4:QLand
|
|
// @Values{Copter}: 0:None,1:Land,2:RTL,3:SmartRTL or RTL,4:SmartRTL or Land,5:Terminate
|
|
// @Values{Sub}: 0:None,2:Disarm,3:Enter surface mode
|
|
// @Values{Rover}: 0:None,1:RTL,2:Hold,3:SmartRTL,4:SmartRTL or Hold,5:Terminate
|
|
// @Values{Tracker}: 0:None
|
|
// @User: Standard
|
|
AP_GROUPINFO("FS_LOW_ACT", 16, AP_BattMonitor_Params, _failsafe_low_action, 0),
|
|
|
|
// @Param: FS_CRT_ACT
|
|
// @DisplayName: Critical battery failsafe action
|
|
// @Description: What action the vehicle should perform if it hits a critical battery failsafe
|
|
// @Values{Plane}: 0:None,1:RTL,2:Land,3:Terminate,4:QLand
|
|
// @Values{Copter}: 0:None,1:Land,2:RTL,3:SmartRTL or RTL,4:SmartRTL or Land,5:Terminate
|
|
// @Values{Sub}: 0:None,2:Disarm,3:Enter surface mode
|
|
// @Values{Rover}: 0:None,1:RTL,2:Hold,3:SmartRTL,4:SmartRTL or Hold,5:Terminate
|
|
// @Values{Tracker}: 0:None
|
|
// @User: Standard
|
|
AP_GROUPINFO("FS_CRT_ACT", 17, AP_BattMonitor_Params, _failsafe_critical_action, 0),
|
|
|
|
// @Param: ARM_VOLT
|
|
// @DisplayName: Required arming voltage
|
|
// @Description: Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.
|
|
// @Units: V
|
|
// @Increment: 0.1
|
|
// @User: Advanced
|
|
AP_GROUPINFO("ARM_VOLT", 18, AP_BattMonitor_Params, _arming_minimum_voltage, 0),
|
|
|
|
// @Param: ARM_MAH
|
|
// @DisplayName: Required arming remaining capacity
|
|
// @Description: Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the @PREFIX@_ARM_VOLT parameter.
|
|
// @Units: mAh
|
|
// @Increment: 50
|
|
// @User: Advanced
|
|
AP_GROUPINFO("ARM_MAH", 19, AP_BattMonitor_Params, _arming_minimum_capacity, 0),
|
|
|
|
AP_GROUPEND
|
|
|
|
};
|
|
|
|
AP_BattMonitor_Params::AP_BattMonitor_Params(void) {
|
|
AP_Param::setup_object_defaults(this, var_info);
|
|
}
|