const AP_Param::GroupInfo AC_Sprayer::var_info[] = {
|
|
// @Param: ENABLE
|
|
// @DisplayName: Sprayer enable/disable
|
|
// @Description: Allows you to enable (1) or disable (0) the sprayer
|
|
// @Values: 0:Disabled,1:Enabled
|
|
// @User: Standard
|
|
AP_GROUPINFO_FLAGS("ENABLE", 0, AC_Sprayer, _enabled, 0, AP_PARAM_FLAG_ENABLE),
|
|
|
|
// @Param: PUMP_RATE
|
|
// @DisplayName: Pump speed
|
|
// @Description: Desired pump speed when traveling 1m/s expressed as a percentage
|
|
// @Units: %
|
|
// @Range: 0 100
|
|
// @User: Standard
|
|
AP_GROUPINFO("PUMP_RATE", 1, AC_Sprayer, _pump_pct_1ms, AC_SPRAYER_DEFAULT_PUMP_RATE),
|
|
|
|
// @Param: SPINNER
|
|
// @DisplayName: Spinner rotation speed
|
|
// @Description: Spinner's rotation speed in PWM (a higher rate will disperse the spray over a wider area horizontally)
|
|
// @Units: ms
|
|
// @Range: 1000 2000
|
|
// @User: Standard
|
|
AP_GROUPINFO("SPINNER", 2, AC_Sprayer, _spinner_pwm, AC_SPRAYER_DEFAULT_SPINNER_PWM),
|
|
|
|
// @Param: SPEED_MIN
|
|
// @DisplayName: Speed minimum
|
|
// @Description: Speed minimum at which we will begin spraying
|
|
// @Units: cm/s
|
|
// @Range: 0 1000
|
|
// @User: Standard
|
|
AP_GROUPINFO("SPEED_MIN", 3, AC_Sprayer, _speed_min, AC_SPRAYER_DEFAULT_SPEED_MIN),
|
|
|
|
// @Param: PUMP_MIN
|
|
// @DisplayName: Pump speed minimum
|
|
// @Description: Minimum pump speed expressed as a percentage
|
|
// @Units: %
|
|
// @Range: 0 100
|
|
// @User: Standard
|
|
AP_GROUPINFO("PUMP_MIN", 4, AC_Sprayer, _pump_min_pct, AC_SPRAYER_DEFAULT_PUMP_MIN),
|
|
|
|
AP_GROUPEND
|
|
};
|
|
|
|
AC_Sprayer::AC_Sprayer()
|
|
{
|
|
if (_s_instance) {
|
|
#if CONFIG_HAL_BOARD == HAL_BOARD_SITL
|
|
AP_HAL::panic("Too many sprayers");
|
|
#endif
|
|
return;
|
|
}
|
|
_s_instance = this;
|
|
|
|
AP_Param::setup_object_defaults(this, var_info);
|
|
|
|
// check for silly parameter values
|
|
if (_pump_pct_1ms < 0.0f || _pump_pct_1ms > 100.0f) {
|
|
_pump_pct_1ms.set_and_save(AC_SPRAYER_DEFAULT_PUMP_RATE);
|
|
}
|
|
if (_spinner_pwm < 0) {
|
|
_spinner_pwm.set_and_save(AC_SPRAYER_DEFAULT_SPINNER_PWM);
|
|
}
|
|
|
|
// To-Do: ensure that the pump and spinner servo channels are enabled
|
|
}
|
|
|
|
/*
|
|
* Get the AP_Sprayer singleton
|
|
*/
|
|
AC_Sprayer *AC_Sprayer::_s_instance = nullptr;
|
|
AC_Sprayer *AC_Sprayer::get_instance()
|
|
{
|
|
return _s_instance;
|
|
}
|
|
|
|
void AC_Sprayer::run(const bool true_false)
|
|
{
|
|
// return immediately if no change
|
|
if (true_false == _flags.running) {
|
|
return;
|
|
}
|
|
|
|
// set flag indicate whether spraying is permitted:
|
|
// do not allow running to be set to true if we are currently not enabled
|
|
_flags.running = true_false && _enabled;
|
|
|
|
// turn off the pump and spinner servos if necessary
|
|
if (!_flags.running) {
|
|
stop_spraying();
|
|
}
|
|
}
|
|
|
|
void AC_Sprayer::stop_spraying()
|
|
{
|
|
SRV_Channels::set_output_limit(SRV_Channel::k_sprayer_pump, SRV_Channel::SRV_CHANNEL_LIMIT_MIN);
|
|
SRV_Channels::set_output_limit(SRV_Channel::k_sprayer_spinner, SRV_Channel::SRV_CHANNEL_LIMIT_MIN);
|
|
|
|
_flags.spraying = false;
|
|
}
|
|
|
|
/// update - adjust pwm of servo controlling pump speed according to the desired quantity and our horizontal speed
|
|
void AC_Sprayer::update()
|
|
{
|
|
// exit immediately if we are disabled or shouldn't be running
|
|
if (!_enabled || !running()) {
|
|
run(false);
|
|
return;
|
|
}
|
|
|
|
// exit immediately if the pump function has not been set-up for any servo
|
|
if (!SRV_Channels::function_assigned(SRV_Channel::k_sprayer_pump)) {
|
|
return;
|
|
}
|
|
|
|
// get horizontal velocity
|
|
Vector3f velocity;
|
|
if (!AP::ahrs().get_velocity_NED(velocity)) {
|
|
// treat unknown velocity as zero which should lead to pump stopping
|
|
// velocity will already be zero but this avoids a coverity warning
|
|
velocity.zero();
|
|
}
|
|
float ground_speed = norm(velocity.x * 100.0f, velocity.y * 100.0f);
|
|
|
|
// get the current time
|
|
const uint32_t now = AP_HAL::millis();
|
|
|
|
bool should_be_spraying = _flags.spraying;
|
|
// check our speed vs the minimum
|
|
if (ground_speed >= _speed_min) {
|
|
// if we are not already spraying
|
|
if (!_flags.spraying) {
|
|
// set the timer if this is the first time we've surpassed the min speed
|
|
if (_speed_over_min_time == 0) {
|
|
_speed_over_min_time = now;
|
|
}else{
|
|
// check if we've been over the speed long enough to engage the sprayer
|
|
if((now - _speed_over_min_time) > AC_SPRAYER_DEFAULT_TURN_ON_DELAY) {
|
|
should_be_spraying = true;
|
|
_speed_over_min_time = 0;
|
|
}
|
|
}
|
|
}
|
|
// reset the speed under timer
|
|
_speed_under_min_time = 0;
|
|
} else {
|
|
// we are under the min speed.
|
|
if (_flags.spraying) {
|
|
// set the timer if this is the first time we've dropped below the min speed
|
|
if (_speed_under_min_time == 0) {
|
|
_speed_under_min_time = now;
|
|
}else{
|
|
// check if we've been over the speed long enough to engage the sprayer
|
|
if((now - _speed_under_min_time) > AC_SPRAYER_DEFAULT_SHUT_OFF_DELAY) {
|
|
should_be_spraying = false;
|
|
_speed_under_min_time = 0;
|
|
}
|
|
}
|
|
}
|
|
// reset the speed over timer
|
|
_speed_over_min_time = 0;
|
|
}
|
|
|
|
// if testing pump output speed as if traveling at 1m/s
|
|
if (_flags.testing) {
|
|
ground_speed = 100.0f;
|
|
should_be_spraying = true;
|
|
}
|
|
|
|
// if spraying or testing update the pump servo position
|
|
if (should_be_spraying) {
|
|
float pos = ground_speed * _pump_pct_1ms;
|
|
pos = MAX(pos, 100 *_pump_min_pct); // ensure min pump speed
|
|
pos = MIN(pos,10000); // clamp to range
|
|
SRV_Channels::move_servo(SRV_Channel::k_sprayer_pump, pos, 0, 10000);
|
|
SRV_Channels::set_output_pwm(SRV_Channel::k_sprayer_spinner, _spinner_pwm);
|
|
_flags.spraying = true;
|
|
} else {
|
|
stop_spraying();
|
|
}
|
|
}
|
|
|
|
namespace AP {
|
|
|
|
AC_Sprayer *sprayer()
|
|
{
|
|
return AC_Sprayer::get_instance();
|
|
}
|
|
|
|
};
|