mirror of https://github.com/ArduPilot/ardupilot
205 lines
9.0 KiB
C++
205 lines
9.0 KiB
C++
#pragma once
|
|
|
|
#include <AP_Common/AP_Common.h>
|
|
#include <AP_Param/AP_Param.h>
|
|
#include <AP_Math/AP_Math.h>
|
|
#include <GCS_MAVLink/GCS_MAVLink.h>
|
|
#include "AP_BattMonitor_Params.h"
|
|
|
|
// maximum number of battery monitors
|
|
#define AP_BATT_MONITOR_MAX_INSTANCES 9
|
|
|
|
// first monitor is always the primary monitor
|
|
#define AP_BATT_PRIMARY_INSTANCE 0
|
|
|
|
#define AP_BATT_SERIAL_NUMBER_DEFAULT -1
|
|
|
|
#define AP_BATT_MONITOR_TIMEOUT 5000
|
|
|
|
#define AP_BATT_MONITOR_RES_EST_TC_1 0.5f
|
|
#define AP_BATT_MONITOR_RES_EST_TC_2 0.1f
|
|
|
|
// declare backend class
|
|
class AP_BattMonitor_Backend;
|
|
class AP_BattMonitor_Analog;
|
|
class AP_BattMonitor_SMBus;
|
|
class AP_BattMonitor_SMBus_Solo;
|
|
class AP_BattMonitor_SMBus_Maxell;
|
|
class AP_BattMonitor_UAVCAN;
|
|
|
|
class AP_BattMonitor
|
|
{
|
|
friend class AP_BattMonitor_Backend;
|
|
friend class AP_BattMonitor_Analog;
|
|
friend class AP_BattMonitor_SMBus;
|
|
friend class AP_BattMonitor_SMBus_Solo;
|
|
friend class AP_BattMonitor_SMBus_Maxell;
|
|
friend class AP_BattMonitor_UAVCAN;
|
|
friend class AP_BattMonitor_Sum;
|
|
friend class AP_BattMonitor_FuelFlow;
|
|
|
|
public:
|
|
|
|
// battery failsafes must be defined in levels of severity so that vehicles wont fall backwards
|
|
enum BatteryFailsafe {
|
|
BatteryFailsafe_None = 0,
|
|
BatteryFailsafe_Low,
|
|
BatteryFailsafe_Critical
|
|
};
|
|
|
|
FUNCTOR_TYPEDEF(battery_failsafe_handler_fn_t, void, const char *, const int8_t);
|
|
|
|
AP_BattMonitor(uint32_t log_battery_bit, battery_failsafe_handler_fn_t battery_failsafe_handler_fn, const int8_t *failsafe_priorities);
|
|
|
|
/* Do not allow copies */
|
|
AP_BattMonitor(const AP_BattMonitor &other) = delete;
|
|
AP_BattMonitor &operator=(const AP_BattMonitor&) = delete;
|
|
|
|
static AP_BattMonitor *get_singleton() {
|
|
return _singleton;
|
|
}
|
|
|
|
struct cells {
|
|
uint16_t cells[MAVLINK_MSG_BATTERY_STATUS_FIELD_VOLTAGES_LEN];
|
|
};
|
|
|
|
// The BattMonitor_State structure is filled in by the backend driver
|
|
struct BattMonitor_State {
|
|
cells cell_voltages; // battery cell voltages in millivolts, 10 cells matches the MAVLink spec
|
|
float voltage; // voltage in volts
|
|
float current_amps; // current in amperes
|
|
float consumed_mah; // total current draw in milliamp hours since start-up
|
|
float consumed_wh; // total energy consumed in Wh since start-up
|
|
uint32_t last_time_micros; // time when voltage and current was last read in microseconds
|
|
uint32_t low_voltage_start_ms; // time when voltage dropped below the minimum in milliseconds
|
|
uint32_t critical_voltage_start_ms; // critical voltage failsafe start timer in milliseconds
|
|
float temperature; // battery temperature in degrees Celsius
|
|
uint32_t temperature_time; // timestamp of the last received temperature message
|
|
float voltage_resting_estimate; // voltage with sag removed based on current and resistance estimate in Volt
|
|
float resistance; // resistance, in Ohms, calculated by comparing resting voltage vs in flight voltage
|
|
BatteryFailsafe failsafe; // stage failsafe the battery is in
|
|
bool healthy; // battery monitor is communicating correctly
|
|
bool is_powering_off; // true when power button commands power off
|
|
bool powerOffNotified; // only send powering off notification once
|
|
};
|
|
|
|
// Return the number of battery monitor instances
|
|
uint8_t num_instances(void) const { return _num_instances; }
|
|
|
|
// detect and initialise any available battery monitors
|
|
void init();
|
|
|
|
/// Read the battery voltage and current for all batteries. Should be called at 10hz
|
|
void read();
|
|
|
|
// healthy - returns true if monitor is functioning
|
|
bool healthy(uint8_t instance) const;
|
|
bool healthy() const { return healthy(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// has_consumed_energy - returns true if battery monitor instance provides consumed energy info
|
|
bool has_consumed_energy(uint8_t instance) const;
|
|
bool has_consumed_energy() const { return has_consumed_energy(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// has_current - returns true if battery monitor instance provides current info
|
|
bool has_current(uint8_t instance) const;
|
|
bool has_current() const { return has_current(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// voltage - returns battery voltage in millivolts
|
|
float voltage(uint8_t instance) const;
|
|
float voltage() const { return voltage(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// get voltage with sag removed (based on battery current draw and resistance)
|
|
/// this will always be greater than or equal to the raw voltage
|
|
float voltage_resting_estimate(uint8_t instance) const;
|
|
float voltage_resting_estimate() const { return voltage_resting_estimate(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// current_amps - returns the instantaneous current draw in amperes
|
|
float current_amps(uint8_t instance) const;
|
|
float current_amps() const { return current_amps(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// consumed_mah - returns total current drawn since start-up in milliampere.hours
|
|
float consumed_mah(uint8_t instance) const;
|
|
float consumed_mah() const { return consumed_mah(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// consumed_wh - returns total energy drawn since start-up in watt.hours
|
|
float consumed_wh(uint8_t instance) const;
|
|
float consumed_wh() const { return consumed_wh(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// capacity_remaining_pct - returns the % battery capacity remaining (0 ~ 100)
|
|
virtual uint8_t capacity_remaining_pct(uint8_t instance) const;
|
|
uint8_t capacity_remaining_pct() const { return capacity_remaining_pct(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// pack_capacity_mah - returns the capacity of the battery pack in mAh when the pack is full
|
|
int32_t pack_capacity_mah(uint8_t instance) const;
|
|
int32_t pack_capacity_mah() const { return pack_capacity_mah(AP_BATT_PRIMARY_INSTANCE); }
|
|
|
|
/// returns true if a battery failsafe has ever been triggered
|
|
bool has_failsafed(void) const { return _has_triggered_failsafe; };
|
|
|
|
/// returns the highest failsafe action that has been triggered
|
|
int8_t get_highest_failsafe_priority(void) const { return _highest_failsafe_priority; };
|
|
|
|
/// get_type - returns battery monitor type
|
|
enum AP_BattMonitor_Params::BattMonitor_Type get_type() const { return get_type(AP_BATT_PRIMARY_INSTANCE); }
|
|
enum AP_BattMonitor_Params::BattMonitor_Type get_type(uint8_t instance) const { return _params[instance].type(); }
|
|
|
|
/// true when (voltage * current) > watt_max
|
|
bool overpower_detected() const;
|
|
bool overpower_detected(uint8_t instance) const;
|
|
|
|
// cell voltages
|
|
bool has_cell_voltages() { return has_cell_voltages(AP_BATT_PRIMARY_INSTANCE); }
|
|
bool has_cell_voltages(const uint8_t instance) const;
|
|
const cells & get_cell_voltages() const { return get_cell_voltages(AP_BATT_PRIMARY_INSTANCE); }
|
|
const cells & get_cell_voltages(const uint8_t instance) const;
|
|
|
|
// temperature
|
|
bool get_temperature(float &temperature) const { return get_temperature(temperature, AP_BATT_PRIMARY_INSTANCE); };
|
|
bool get_temperature(float &temperature, const uint8_t instance) const;
|
|
|
|
// get battery resistance estimate in ohms
|
|
float get_resistance() const { return get_resistance(AP_BATT_PRIMARY_INSTANCE); }
|
|
float get_resistance(uint8_t instance) const { return state[instance].resistance; }
|
|
|
|
// returns false if we fail arming checks, in which case the buffer will be populated with a failure message
|
|
bool arming_checks(size_t buflen, char *buffer) const;
|
|
|
|
// sends powering off mavlink broadcasts and sets notify flag
|
|
void checkPoweringOff(void);
|
|
|
|
// reset battery remaining percentage
|
|
bool reset_remaining(uint16_t battery_mask, float percentage);
|
|
|
|
static const struct AP_Param::GroupInfo var_info[];
|
|
|
|
protected:
|
|
|
|
/// parameters
|
|
AP_BattMonitor_Params _params[AP_BATT_MONITOR_MAX_INSTANCES];
|
|
|
|
private:
|
|
static AP_BattMonitor *_singleton;
|
|
|
|
BattMonitor_State state[AP_BATT_MONITOR_MAX_INSTANCES];
|
|
AP_BattMonitor_Backend *drivers[AP_BATT_MONITOR_MAX_INSTANCES];
|
|
uint32_t _log_battery_bit;
|
|
uint8_t _num_instances; /// number of monitors
|
|
|
|
void convert_params(void);
|
|
|
|
/// returns the failsafe state of the battery
|
|
BatteryFailsafe check_failsafe(const uint8_t instance);
|
|
void check_failsafes(void); // checks all batteries failsafes
|
|
|
|
battery_failsafe_handler_fn_t _battery_failsafe_handler_fn;
|
|
const int8_t *_failsafe_priorities; // array of failsafe priorities, sorted highest to lowest priority, -1 indicates no more entries
|
|
|
|
int8_t _highest_failsafe_priority; // highest selected failsafe action level (used to restrict what actions we move into)
|
|
bool _has_triggered_failsafe; // true after a battery failsafe has been triggered for the first time
|
|
|
|
};
|
|
|
|
namespace AP {
|
|
AP_BattMonitor &battery();
|
|
};
|