-- example of getting RC input local scripting_rc_1 = rc:find_channel_for_option(300) local scripting_rc_2 = rc:find_channel_for_option(301) function update() pwm1 = rc:get_pwm(1) pwm2 = rc:get_pwm(2) pwm3 = rc:get_pwm(3) pwm4 = rc:get_pwm(4) gcs:send_text(0, "RCIN 1:" .. tostring(pwm1) .. " 2:" .. tostring(pwm2).. " 3:" .. tostring(pwm3).. " 4:" .. tostring(pwm4)) -- read normalized input from designated scripting RCx_OPTION if scripting_rc_1 then gcs:send_text(0, "Scripting in 1:" .. tostring(scripting_rc_1:norm_input())) end -- read switch input from second designated scripting RCx_OPTION if scripting_rc_2 then local sw_pos = scripting_rc_2:get_aux_switch_pos() if sw_pos == 0 then gcs:send_text(0, "Scripting switch is low") elseif sw_pos == 1 then gcs:send_text(0, "Scripting switch is middle") else gcs:send_text(0, "Scripting switch is high") end end return update, 1000 -- reschedules the loop end return update()