priseborough 063fb41748 AP_OpticalFlow: Add separate scale factors for X and Y axis.
The resolution is also increased to take advantage of the planned introduction of automated calibration methods
2014-12-06 18:16:49 +11:00
priseborough 52c7e56a4a AP_NavEKF: Add parameter for max valid optical flow rate magnitude 2014-12-06 18:16:49 +11:00
priseborough 6f8971d80a AP_NavEKF: Speed up flow sensor gyro bias correction 2014-12-06 18:16:49 +11:00
priseborough d7ad45ebda AP_NavEKF: Don't fuse flow measurements if too big 2014-12-06 18:16:49 +11:00
priseborough 2dff76394d AC_PosControl: Add spike and noise filter to demanded angles
This has been done to provide a smooth psotion hold when using an optical flow aided EKF which can be noisy.

Signed-off-by: priseborough <p_riseborough@live.com.au>
2014-12-06 18:16:49 +11:00
priseborough 84944fdd4e AP_NAvEKF: Revert back to 10Hz fusion 2014-12-06 18:16:49 +11:00
priseborough f4f0dfc45c AP_OpticalFlow: efficiency improvements to data processing 2014-12-06 18:16:49 +11:00
priseborough 1f78a73cdb AP_NavEKF: Make flow measurement delay vehicle specific
This takes into account the inter-sampling delay between the flow driver and the APM software which depends on the rate at which the dirver is being checked. This is 50Hz for plane and rover, and 200Hz for Copter.
2014-12-06 18:16:49 +11:00
priseborough f23722ecee Plane: Remove statement about flow driver rate in comment 2014-12-06 18:16:48 +11:00
priseborough 5f941655a8 AP_NavEKF: changes to support to 20Hz flow fusion rate 2014-12-06 18:16:48 +11:00
priseborough 715d64dce9 Copter: Check for new optical flow updates at 200Hz
Supports use of higher flow read rates if required.
2014-12-06 18:16:48 +11:00
priseborough ca53d5fb62 Plane: Increase rate at which optical flow sensor is checked
The sensor driver runs asynchronously at 10Hz, so needs to be checked frequently for arrival of data.
2014-12-06 18:16:48 +11:00
priseborough 468c83c074 Copter : Check for new optical flow readings every 10ms
The driver polls the sensor asynchronously every 100 msec, so we need to continually check for new data.
2014-12-06 18:16:48 +11:00
priseborough 0bf991eef9 AP_NavEKF: Fix bug in optical flow fusion smoothing 2014-12-06 18:16:48 +11:00
priseborough 7d27a22f77 DataFlash : Fix EKF optical flow logging bug 2014-12-06 18:16:48 +11:00
priseborough 7ec8dfebcf AP_OpticalFlow : Remove gyro scale factor user adjustable parameter
No longer required because bug in flow sensor has been fixed.
2014-12-06 18:16:48 +11:00
priseborough 898ad7432b Plane : Only build optical flow with PX4 board
Fixes SITL compile errors
2014-12-06 18:16:48 +11:00
priseborough be54f2d6ee Copter : Don't force pre-compiler inclusion of optical flow 2014-12-06 18:16:48 +11:00
priseborough 2baa1e56ed Dataflash : Fix bug in EKF opt flow logging 2014-12-06 18:16:48 +11:00
priseborough df59f3311a AP_OpticalFlow : Add gyro scale factor correction parameter 2014-12-06 18:16:48 +11:00
priseborough eec49ce1dd AP_OpticalFlow : Add parameter for flow rate scale factor correction 2014-12-06 18:16:48 +11:00
priseborough 2500f7e9c2 Plane : Add data logging for optical flow use with EKF 2014-12-06 18:16:48 +11:00
priseborough 2db9247117 Plane : Add logging and EKF read for updated flow sensor interface 2014-12-06 18:16:47 +11:00
priseborough 6d5fb33d1a Copter : enable optical flow by default 2014-12-06 18:16:47 +11:00
priseborough 45c007d216 Copter : Correct comment on required optical flow update rate 2014-12-06 18:16:47 +11:00
priseborough 839b814d12 AP_NavEKF : Inhibit flow and range fusion in static mode 2014-12-06 18:16:47 +11:00
priseborough 9b9934ac06 AP_NavEKF : fix velocity timeout bug during optical flow operation 2014-12-06 18:16:47 +11:00
priseborough cc8e6dbfad DataFlash : Add EKF additional fault and timeout logging 2014-12-06 18:16:47 +11:00
priseborough 517026980b AP_NavEKF : Add fault and timeout logging 2014-12-06 18:16:47 +11:00
priseborough f640ec30ff AP_NavEKF : Reset held velocity on arming
This held velocity is used to constrain the drift in the optical flow solution before the vehicle is high enough for the optical flow sensor to work.
2014-12-06 18:16:47 +11:00
priseborough 4616721b0d DataFlash : Update EKF debug logging 2014-12-06 18:16:47 +11:00
priseborough 06c19a3a4d AP_NavEKF : Update optical flow debug logging 2014-12-06 18:16:47 +11:00
priseborough 1791dec622 AP_NavEKF : Fix velocity hold mode 2014-12-06 18:16:47 +11:00
priseborough 84421e0a35 AP_NavEKF : Adjust initial flow scale factor and limits 2014-12-06 18:16:47 +11:00
priseborough 573633daf7 AP_NavEKF : Fix incorrect use of flow sensor time-stamp
flow sensor time stamp is now issued by the flow sensor and is on a different time-base
2014-12-06 18:16:47 +11:00
priseborough 92e9336fe1 AP_OpticalFlow : prevent divide by zero 2014-12-06 18:16:47 +11:00
priseborough 9ea97c1a38 AP_NavEKF : Modify optical flow data interface
Sign conventions have changed
2014-12-06 18:16:46 +11:00
priseborough a72b6b179b Copter : Modify EKF optical flow data interface 2014-12-06 18:16:46 +11:00
priseborough 311206017c Copter : Update EKF optical flow data interface
Makes it compatible with the new PX4Flow interface
2014-12-06 18:16:46 +11:00
priseborough 8faeb190de AP_NavEKF : Rework logic to cope with bad flow data 2014-12-06 18:16:46 +11:00
priseborough 44e1695d5a AP_AHRS : Enable EKF start without GPS 2014-12-06 18:16:46 +11:00
priseborough 41f0231cfb AP_NavEKF : improve logic dealing with lack of flow or range data 2014-12-06 18:16:46 +11:00
priseborough f047e35167 Plane : Enable optical flow by default if sensor is fitted 2014-12-06 18:16:46 +11:00
priseborough 9ba46ad795 AP_NavEKF : Improve handling of flow sensor failure 2014-12-06 18:16:46 +11:00
priseborough 2ee1c549be AP_NavEKF : improve criteria used to inhibit scale factor estimation 2014-12-06 18:16:46 +11:00
priseborough e09ff84218 AP_NavEKF : Don't estimate focal length scale factor without reliable velocity 2014-12-06 18:16:46 +11:00
priseborough 4c92a5f23f AP_NavEKF : Use GPS velocity if PX4Flow sensor fails 2014-12-06 18:16:46 +11:00
priseborough 283811edcb AP_NavEKF : stop velocity change when flow measurements drop out 2014-12-06 18:16:46 +11:00
priseborough 9132fcfe43 AP_NavEKF : Change mag fusion to use corrected compass values
This enables compass units to be switched in-flight
2014-12-06 18:16:46 +11:00
priseborough c3be486c29 AP_NavEKF : Enable inhibiting of GPS measurements 2014-12-06 18:16:45 +11:00