AP_OpticalFlow: efficiency improvements to data processing

This commit is contained in:
priseborough 2014-11-07 22:59:02 +11:00 committed by Andrew Tridgell
parent 1f78a73cdb
commit f4f0dfc45c
1 changed files with 5 additions and 4 deletions

View File

@ -65,10 +65,11 @@ void AP_OpticalFlow_PX4::update(void)
_surface_quality = report.quality; _surface_quality = report.quality;
if (report.integration_timespan > 0) { if (report.integration_timespan > 0) {
float flowScaleFactor = 0.01f * float(100 + _flowScaler); float flowScaleFactor = 0.01f * float(100 + _flowScaler);
_flowRate.x = flowScaleFactor * report.pixel_flow_x_integral / (report.integration_timespan / 1e6f); // rad/sec measured optically about the X sensor axis float integralToRate = 1e6f / float(report.integration_timespan);
_flowRate.y = flowScaleFactor * report.pixel_flow_y_integral / (report.integration_timespan / 1e6f); // rad/sec measured optically about the Y sensor axis _flowRate.x = flowScaleFactor * integralToRate * float(report.pixel_flow_x_integral); // rad/sec measured optically about the X sensor axis
_bodyRate.x = report.gyro_x_rate_integral / (report.integration_timespan / 1e6f); // rad/sec measured inertially about the X sensor axis _flowRate.y = flowScaleFactor * integralToRate * float(report.pixel_flow_y_integral); // rad/sec measured optically about the Y sensor axis
_bodyRate.y = report.gyro_y_rate_integral / (report.integration_timespan / 1e6f); // rad/sec measured inertially about the Y sensor axis _bodyRate.x = integralToRate * float(report.gyro_x_rate_integral); // rad/sec measured inertially about the X sensor axis
_bodyRate.y = integralToRate * float(report.gyro_y_rate_integral); // rad/sec measured inertially about the Y sensor axis
} else { } else {
_flowRate.x = 0.0f; _flowRate.x = 0.0f;
_flowRate.y = 0.0f; _flowRate.y = 0.0f;