mirror of
https://github.com/ArduPilot/ardupilot
synced 2025-01-03 06:28:27 -04:00
AP_BattMonitor: add torqeedo battery monitor
This commit is contained in:
parent
866ea184c8
commit
d3c8a5e85f
@ -16,6 +16,7 @@
|
|||||||
#include "AP_BattMonitor_MPPT_PacketDigital.h"
|
#include "AP_BattMonitor_MPPT_PacketDigital.h"
|
||||||
#include "AP_BattMonitor_INA231.h"
|
#include "AP_BattMonitor_INA231.h"
|
||||||
#include "AP_BattMonitor_LTC2946.h"
|
#include "AP_BattMonitor_LTC2946.h"
|
||||||
|
#include "AP_BattMonitor_Torqeedo.h"
|
||||||
|
|
||||||
#include <AP_HAL/AP_HAL.h>
|
#include <AP_HAL/AP_HAL.h>
|
||||||
|
|
||||||
@ -306,6 +307,11 @@ AP_BattMonitor::init()
|
|||||||
case Type::LTC2946:
|
case Type::LTC2946:
|
||||||
drivers[instance] = new AP_BattMonitor_LTC2946(*this, state[instance], _params[instance]);
|
drivers[instance] = new AP_BattMonitor_LTC2946(*this, state[instance], _params[instance]);
|
||||||
break;
|
break;
|
||||||
|
#endif
|
||||||
|
#if HAL_TORQEEDO_ENABLED
|
||||||
|
case Type::Torqeedo:
|
||||||
|
drivers[instance] = new AP_BattMonitor_Torqeedo(*this, state[instance], _params[instance]);
|
||||||
|
break;
|
||||||
#endif
|
#endif
|
||||||
case Type::NONE:
|
case Type::NONE:
|
||||||
default:
|
default:
|
||||||
|
@ -48,6 +48,7 @@ class AP_BattMonitor_Generator;
|
|||||||
class AP_BattMonitor_MPPT_PacketDigital;
|
class AP_BattMonitor_MPPT_PacketDigital;
|
||||||
class AP_BattMonitor_INA231;
|
class AP_BattMonitor_INA231;
|
||||||
class AP_BattMonitor_LTC2946;
|
class AP_BattMonitor_LTC2946;
|
||||||
|
class AP_BattMonitor_Torqeedo;
|
||||||
|
|
||||||
class AP_BattMonitor
|
class AP_BattMonitor
|
||||||
{
|
{
|
||||||
@ -67,6 +68,8 @@ class AP_BattMonitor
|
|||||||
friend class AP_BattMonitor_INA231;
|
friend class AP_BattMonitor_INA231;
|
||||||
friend class AP_BattMonitor_LTC2946;
|
friend class AP_BattMonitor_LTC2946;
|
||||||
|
|
||||||
|
friend class AP_BattMonitor_Torqeedo;
|
||||||
|
|
||||||
public:
|
public:
|
||||||
|
|
||||||
// battery failsafes must be defined in levels of severity so that vehicles wont fall backwards
|
// battery failsafes must be defined in levels of severity so that vehicles wont fall backwards
|
||||||
@ -99,6 +102,7 @@ public:
|
|||||||
MPPT_PacketDigital = 20,
|
MPPT_PacketDigital = 20,
|
||||||
INA231 = 21,
|
INA231 = 21,
|
||||||
LTC2946 = 22,
|
LTC2946 = 22,
|
||||||
|
Torqeedo = 23,
|
||||||
};
|
};
|
||||||
|
|
||||||
FUNCTOR_TYPEDEF(battery_failsafe_handler_fn_t, void, const char *, const int8_t);
|
FUNCTOR_TYPEDEF(battery_failsafe_handler_fn_t, void, const char *, const int8_t);
|
||||||
|
@ -13,7 +13,7 @@ const AP_Param::GroupInfo AP_BattMonitor_Params::var_info[] = {
|
|||||||
// @Param: MONITOR
|
// @Param: MONITOR
|
||||||
// @DisplayName: Battery monitoring
|
// @DisplayName: Battery monitoring
|
||||||
// @Description: Controls enabling monitoring of the battery's voltage and current
|
// @Description: Controls enabling monitoring of the battery's voltage and current
|
||||||
// @Values: 0:Disabled,3:Analog Voltage Only,4:Analog Voltage and Current,5:Solo,6:Bebop,7:SMBus-Generic,8:UAVCAN-BatteryInfo,9:ESC,10:SumOfFollowing,11:FuelFlow,12:FuelLevelPWM,13:SMBUS-SUI3,14:SMBUS-SUI6,15:NeoDesign,16:SMBus-Maxell,17:Generator-Elec,18:Generator-Fuel,19:Rotoye,20:MPPT,21:INA231,22:LTC2946
|
// @Values: 0:Disabled,3:Analog Voltage Only,4:Analog Voltage and Current,5:Solo,6:Bebop,7:SMBus-Generic,8:UAVCAN-BatteryInfo,9:ESC,10:SumOfFollowing,11:FuelFlow,12:FuelLevelPWM,13:SMBUS-SUI3,14:SMBUS-SUI6,15:NeoDesign,16:SMBus-Maxell,17:Generator-Elec,18:Generator-Fuel,19:Rotoye,20:MPPT,21:INA231,22:LTC2946,23:Torqeedo
|
||||||
// @User: Standard
|
// @User: Standard
|
||||||
// @RebootRequired: True
|
// @RebootRequired: True
|
||||||
AP_GROUPINFO_FLAGS("MONITOR", 1, AP_BattMonitor_Params, _type, int8_t(AP_BattMonitor::Type::NONE), AP_PARAM_FLAG_ENABLE),
|
AP_GROUPINFO_FLAGS("MONITOR", 1, AP_BattMonitor_Params, _type, int8_t(AP_BattMonitor::Type::NONE), AP_PARAM_FLAG_ENABLE),
|
||||||
|
77
libraries/AP_BattMonitor/AP_BattMonitor_Torqeedo.cpp
Normal file
77
libraries/AP_BattMonitor/AP_BattMonitor_Torqeedo.cpp
Normal file
@ -0,0 +1,77 @@
|
|||||||
|
/*
|
||||||
|
This program is free software: you can redistribute it and/or modify
|
||||||
|
it under the terms of the GNU General Public License as published by
|
||||||
|
the Free Software Foundation, either version 3 of the License, or
|
||||||
|
(at your option) any later version.
|
||||||
|
|
||||||
|
This program is distributed in the hope that it will be useful,
|
||||||
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||||
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||||||
|
GNU General Public License for more details.
|
||||||
|
|
||||||
|
You should have received a copy of the GNU General Public License
|
||||||
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
||||||
|
*/
|
||||||
|
|
||||||
|
|
||||||
|
#include <AP_HAL/AP_HAL.h>
|
||||||
|
#include "AP_BattMonitor_Torqeedo.h"
|
||||||
|
|
||||||
|
#if HAL_TORQEEDO_ENABLED
|
||||||
|
|
||||||
|
#define AP_BATTMON_TORQEEDO_TIMEOUT_US 5000000
|
||||||
|
|
||||||
|
extern const AP_HAL::HAL &hal;
|
||||||
|
|
||||||
|
void AP_BattMonitor_Torqeedo::read(void)
|
||||||
|
{
|
||||||
|
AP_Torqeedo *torqeedo = AP_Torqeedo::get_singleton();
|
||||||
|
if (torqeedo == nullptr) {
|
||||||
|
_state.healthy = false;
|
||||||
|
return;
|
||||||
|
}
|
||||||
|
|
||||||
|
// get voltage, current, temp and remaining capacity percentage
|
||||||
|
float volts;
|
||||||
|
float current_amps;
|
||||||
|
float temp_C;
|
||||||
|
if (torqeedo->get_batt_info(volts, current_amps, temp_C, remaining_pct)) {
|
||||||
|
have_info = true;
|
||||||
|
_state.voltage = volts;
|
||||||
|
_state.current_amps = current_amps;
|
||||||
|
_state.temperature = temp_C;
|
||||||
|
_state.temperature_time = AP_HAL::millis();
|
||||||
|
|
||||||
|
// update total current draw
|
||||||
|
const uint32_t tnow_us = AP_HAL::micros();
|
||||||
|
const uint32_t diff_us = tnow_us - _state.last_time_micros;
|
||||||
|
if (diff_us < AP_BATTMON_TORQEEDO_TIMEOUT_US) {
|
||||||
|
_state.consumed_mah += _state.current_amps * diff_us / 1000000.0 / 3600.0 * 1000.0;
|
||||||
|
}
|
||||||
|
_state.last_time_micros = tnow_us;
|
||||||
|
_state.healthy = true;
|
||||||
|
}
|
||||||
|
|
||||||
|
// read battery pack capacity
|
||||||
|
if (!have_capacity) {
|
||||||
|
uint16_t batt_capacity_ah;
|
||||||
|
if (torqeedo->get_batt_capacity_Ah(batt_capacity_ah)) {
|
||||||
|
have_capacity = true;
|
||||||
|
if (batt_capacity_ah * 1000 != _params._pack_capacity) {
|
||||||
|
_params._pack_capacity.set_and_notify(batt_capacity_ah * 1000);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
// capacity_remaining_pct - returns true if the battery % is available and writes to the percentage argument
|
||||||
|
// returns false if the battery is unhealthy, does not have current monitoring, or the pack_capacity is too small
|
||||||
|
bool AP_BattMonitor_Torqeedo::capacity_remaining_pct(uint8_t &percentage) const
|
||||||
|
{
|
||||||
|
if (have_info) {
|
||||||
|
percentage = remaining_pct;
|
||||||
|
}
|
||||||
|
return have_info;
|
||||||
|
}
|
||||||
|
|
||||||
|
#endif // HAL_TORQEEDO_ENABLED
|
52
libraries/AP_BattMonitor/AP_BattMonitor_Torqeedo.h
Normal file
52
libraries/AP_BattMonitor/AP_BattMonitor_Torqeedo.h
Normal file
@ -0,0 +1,52 @@
|
|||||||
|
/*
|
||||||
|
This program is free software: you can redistribute it and/or modify
|
||||||
|
it under the terms of the GNU General Public License as published by
|
||||||
|
the Free Software Foundation, either version 3 of the License, or
|
||||||
|
(at your option) any later version.
|
||||||
|
|
||||||
|
This program is distributed in the hope that it will be useful,
|
||||||
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
||||||
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
||||||
|
GNU General Public License for more details.
|
||||||
|
|
||||||
|
You should have received a copy of the GNU General Public License
|
||||||
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
||||||
|
*/
|
||||||
|
#pragma once
|
||||||
|
|
||||||
|
#include <AP_Common/AP_Common.h>
|
||||||
|
#include <AP_HAL/AP_HAL.h>
|
||||||
|
#include <AP_Torqeedo/AP_Torqeedo.h>
|
||||||
|
#include "AP_BattMonitor_Backend.h"
|
||||||
|
|
||||||
|
#if HAL_TORQEEDO_ENABLED
|
||||||
|
|
||||||
|
class AP_BattMonitor_Torqeedo: public AP_BattMonitor_Backend
|
||||||
|
{
|
||||||
|
public:
|
||||||
|
// constructor. This incorporates initialisation as well.
|
||||||
|
AP_BattMonitor_Torqeedo(AP_BattMonitor &mon, AP_BattMonitor::BattMonitor_State &mon_state, AP_BattMonitor_Params ¶ms):
|
||||||
|
AP_BattMonitor_Backend(mon, mon_state, params)
|
||||||
|
{};
|
||||||
|
|
||||||
|
// read the latest battery voltage
|
||||||
|
void read() override;
|
||||||
|
|
||||||
|
/// returns true if battery monitor instance provides current info
|
||||||
|
bool has_current() const override { return have_info; };
|
||||||
|
|
||||||
|
// returns true if battery monitor provides temperature
|
||||||
|
bool has_temperature() const override { return have_info; };
|
||||||
|
|
||||||
|
// capacity_remaining_pct - returns true if the battery % is available and writes to the percentage argument
|
||||||
|
// returns false if the battery is unhealthy, does not have current monitoring, or the pack_capacity is too small
|
||||||
|
bool capacity_remaining_pct(uint8_t &percentage) const override WARN_IF_UNUSED;
|
||||||
|
|
||||||
|
private:
|
||||||
|
|
||||||
|
bool have_info; // true if torqeedo has provided battery info at least once
|
||||||
|
bool have_capacity; // true once torqeedo has provided battery capacity
|
||||||
|
uint8_t remaining_pct; // battery remaining capacity as a percentage
|
||||||
|
};
|
||||||
|
|
||||||
|
#endif
|
Loading…
Reference in New Issue