AP_Generator: rename fuel_remain_pct to fuel_remain_scale

This commit is contained in:
Peter Barker 2023-03-10 18:04:05 +11:00 committed by Peter Barker
parent 6bc9b7c435
commit a32180f709
6 changed files with 14 additions and 13 deletions

View File

@ -38,14 +38,15 @@ public:
// Helpers to retrieve measurements // Helpers to retrieve measurements
float get_voltage(void) const { return _voltage; } float get_voltage(void) const { return _voltage; }
float get_current(void) const { return _current; } float get_current(void) const { return _current; }
float get_fuel_remaining_pct(void) const { return _fuel_remain_pct; } // get_fuel_remaining returns fuel remaining as a scale 0-1
float get_fuel_remaining(void) const { return _fuel_remaining; }
float get_batt_consumed(void) const { return _consumed_mah; } float get_batt_consumed(void) const { return _consumed_mah; }
uint16_t get_rpm(void) const { return _rpm; } uint16_t get_rpm(void) const { return _rpm; }
// Helpers to see if backend has a measurement // Helpers to see if backend has a measurement
bool has_current() const { return _has_current; } bool has_current() const { return _has_current; }
bool has_consumed_energy() const { return _has_consumed_energy; } bool has_consumed_energy() const { return _has_consumed_energy; }
bool has_fuel_remaining_pct() const { return _has_fuel_remaining_pct; } bool has_fuel_remaining() const { return _has_fuel_remaining; }
// healthy() returns true if the generator is not present, or it is // healthy() returns true if the generator is not present, or it is
// present, providing telemetry and not indicating any errors. // present, providing telemetry and not indicating any errors.
@ -99,13 +100,13 @@ private:
// Front end variables // Front end variables
float _voltage; float _voltage;
float _current; float _current;
float _fuel_remain_pct; float _fuel_remaining; // 0-1
bool _has_fuel_remaining;
float _consumed_mah; float _consumed_mah;
uint16_t _rpm; uint16_t _rpm;
bool _healthy; bool _healthy;
bool _has_current; bool _has_current;
bool _has_consumed_energy; bool _has_consumed_energy;
bool _has_fuel_remaining_pct;
static AP_Generator *_singleton; static AP_Generator *_singleton;

View File

@ -29,7 +29,7 @@ void AP_Generator_Backend::update_frontend()
_frontend._voltage = _voltage; _frontend._voltage = _voltage;
_frontend._current = _current; _frontend._current = _current;
_frontend._consumed_mah = _consumed_mah; _frontend._consumed_mah = _consumed_mah;
_frontend._fuel_remain_pct = _fuel_remain_pct; _frontend._fuel_remaining = _fuel_remaining;
_frontend._rpm = _rpm; _frontend._rpm = _rpm;
_frontend._healthy = healthy(); _frontend._healthy = healthy();
} }

View File

@ -43,7 +43,7 @@ protected:
// Measurements readings to write to front end // Measurements readings to write to front end
float _voltage; float _voltage;
float _current; float _current;
float _fuel_remain_pct; // Decimal from 0 to 1 float _fuel_remaining; // Decimal from 0 to 1
float _consumed_mah; float _consumed_mah;
uint16_t _rpm; uint16_t _rpm;

View File

@ -29,7 +29,7 @@ void AP_Generator_IE_2400::init()
// Tell frontend what measurements are available for this generator // Tell frontend what measurements are available for this generator
_frontend._has_current = true; _frontend._has_current = true;
_frontend._has_consumed_energy = true; _frontend._has_consumed_energy = true;
_frontend._has_fuel_remaining_pct = true; _frontend._has_fuel_remaining = true;
} }
// Update fuel cell, expected to be called at 20hz // Update fuel cell, expected to be called at 20hz
@ -43,10 +43,10 @@ void AP_Generator_IE_2400::assign_measurements(const uint32_t now)
_state = (State)_parsed.state; _state = (State)_parsed.state;
_err_code = _parsed.err_code; _err_code = _parsed.err_code;
// Scale tank pressure linearly to a percentage. // Scale tank pressure linearly to a value between 0 and 1
// Min = 5 bar, max = 300 bar, PRESS_GRAD = 1/295. // Min = 5 bar, max = 300 bar, PRESS_GRAD = 1/295.
const float PRESS_GRAD = 0.003389830508f; const float PRESS_GRAD = 0.003389830508f;
_fuel_remain_pct = constrain_float((_parsed.tank_bar-5)*PRESS_GRAD,0,1); _fuel_remaining = constrain_float((_parsed.tank_bar-5)*PRESS_GRAD,0,1);
// Update battery voltage // Update battery voltage
_voltage = _parsed.battery_volt; _voltage = _parsed.battery_volt;
@ -197,7 +197,7 @@ void AP_Generator_IE_2400::log_write()
"F2---", "F2---",
"Qfiii", "Qfiii",
AP_HAL::micros64(), AP_HAL::micros64(),
_fuel_remain_pct, _fuel_remaining,
_spm_pwr, _spm_pwr,
_pwr_out, _pwr_out,
_err_code _err_code

View File

@ -28,7 +28,7 @@ void AP_Generator_IE_650_800::init()
// This unit does not have current but this needs to be true to make use of consumed_mah in BattMonitor // This unit does not have current but this needs to be true to make use of consumed_mah in BattMonitor
_frontend._has_current = true; _frontend._has_current = true;
_frontend._has_consumed_energy = true; _frontend._has_consumed_energy = true;
_frontend._has_fuel_remaining_pct = false; _frontend._has_fuel_remaining = false;
} }
// Update fuel cell, expected to be called at 20hz // Update fuel cell, expected to be called at 20hz
@ -40,7 +40,7 @@ void AP_Generator_IE_650_800::assign_measurements(const uint32_t now)
_err_code = _parsed.err_code; _err_code = _parsed.err_code;
// Update variables to be returned to front end // Update variables to be returned to front end
_fuel_remain_pct = _parsed.tank_pct * 0.01; _fuel_remaining = _parsed.tank_pct * 0.01;
// Invert bat remaining percent to match AP_BattMonitor convention // Invert bat remaining percent to match AP_BattMonitor convention
_consumed_mah = 100.0f - _parsed.battery_pct; _consumed_mah = 100.0f - _parsed.battery_pct;

View File

@ -41,7 +41,7 @@ void AP_Generator_RichenPower::init()
// Tell frontend what measurements are available for this generator // Tell frontend what measurements are available for this generator
_frontend._has_current = true; _frontend._has_current = true;
_frontend._has_consumed_energy = false; _frontend._has_consumed_energy = false;
_frontend._has_fuel_remaining_pct = false; _frontend._has_fuel_remaining = false;
} }