mirror of
https://github.com/ArduPilot/ardupilot
synced 2025-01-30 12:38:33 -04:00
AP_Baro: fixed some signed/unsigned warnings
and a potential bug on timer wrap
This commit is contained in:
parent
d574c78c2c
commit
804332c340
@ -55,7 +55,7 @@
|
|||||||
uint32_t AP_Baro_MS5611::_s_D1;
|
uint32_t AP_Baro_MS5611::_s_D1;
|
||||||
uint32_t AP_Baro_MS5611::_s_D2;
|
uint32_t AP_Baro_MS5611::_s_D2;
|
||||||
uint8_t AP_Baro_MS5611::_state;
|
uint8_t AP_Baro_MS5611::_state;
|
||||||
long AP_Baro_MS5611::_timer;
|
uint32_t AP_Baro_MS5611::_timer;
|
||||||
bool AP_Baro_MS5611::_sync_access;
|
bool AP_Baro_MS5611::_sync_access;
|
||||||
bool AP_Baro_MS5611::_updated;
|
bool AP_Baro_MS5611::_updated;
|
||||||
|
|
||||||
@ -197,25 +197,25 @@ uint8_t AP_Baro_MS5611::read()
|
|||||||
void AP_Baro_MS5611::_calculate()
|
void AP_Baro_MS5611::_calculate()
|
||||||
{
|
{
|
||||||
int32_t dT;
|
int32_t dT;
|
||||||
long long TEMP; // 64 bits
|
int64_t TEMP; // 64 bits
|
||||||
long long OFF;
|
int64_t OFF;
|
||||||
long long SENS;
|
int64_t SENS;
|
||||||
long long P;
|
int64_t P;
|
||||||
|
|
||||||
// Formulas from manufacturer datasheet
|
// Formulas from manufacturer datasheet
|
||||||
// as per data sheet some intermediate results require over 32 bits, therefore
|
// as per data sheet some intermediate results require over 32 bits, therefore
|
||||||
// we define parameters as 64 bits to prevent overflow on operations
|
// we define parameters as 64 bits to prevent overflow on operations
|
||||||
// sub -20c temperature compensation is not included
|
// sub -20c temperature compensation is not included
|
||||||
dT = D2-((long)C5*256);
|
dT = D2-((long)C5*256);
|
||||||
TEMP = 2000 + ((long long)dT * C6)/8388608;
|
TEMP = 2000 + ((int64_t)dT * C6)/8388608;
|
||||||
OFF = (long long)C2 * 65536 + ((long long)C4 * dT ) / 128;
|
OFF = (int64_t)C2 * 65536 + ((int64_t)C4 * dT ) / 128;
|
||||||
SENS = (long long)C1 * 32768 + ((long long)C3 * dT) / 256;
|
SENS = (int64_t)C1 * 32768 + ((int64_t)C3 * dT) / 256;
|
||||||
|
|
||||||
if (TEMP < 2000){ // second order temperature compensation
|
if (TEMP < 2000){ // second order temperature compensation
|
||||||
long long T2 = (long long)dT*dT / 2147483648;
|
int64_t T2 = (((int64_t)dT)*dT) / 2147483648UL;
|
||||||
long long Aux_64 = (TEMP-2000)*(TEMP-2000);
|
int64_t Aux_64 = (TEMP-2000)*(TEMP-2000);
|
||||||
long long OFF2 = 5*Aux_64/2;
|
int64_t OFF2 = 5*Aux_64/2;
|
||||||
long long SENS2 = 5*Aux_64/4;
|
int64_t SENS2 = 5*Aux_64/4;
|
||||||
TEMP = TEMP - T2;
|
TEMP = TEMP - T2;
|
||||||
OFF = OFF - OFF2;
|
OFF = OFF - OFF2;
|
||||||
SENS = SENS - SENS2;
|
SENS = SENS - SENS2;
|
||||||
|
@ -27,7 +27,7 @@ class AP_Baro_MS5611 : public AP_Baro
|
|||||||
static bool _updated;
|
static bool _updated;
|
||||||
static uint32_t _s_D1, _s_D2;
|
static uint32_t _s_D1, _s_D2;
|
||||||
static uint8_t _state;
|
static uint8_t _state;
|
||||||
static long _timer;
|
static uint32_t _timer;
|
||||||
/* Gates access to asynchronous state: */
|
/* Gates access to asynchronous state: */
|
||||||
static bool _sync_access;
|
static bool _sync_access;
|
||||||
|
|
||||||
|
Loading…
Reference in New Issue