mirror of https://github.com/ArduPilot/ardupilot
AP_NavEKF3: Fix bug preventing height reset if badIMUdata
This commit is contained in:
parent
e4eb8339d0
commit
5d00b7d042
|
@ -590,9 +590,9 @@ void NavEKF3_core::FuseVelPosNED()
|
|||
{
|
||||
// health is set bad until test passed
|
||||
bool posHealth = false; // boolean true if position measurements have passed innovation consistency check
|
||||
bool hgtHealth = false; // boolean true if height measurements have passed innovation consistency check
|
||||
|
||||
bool velCheckPassed = false; // boolean true if velocity measurements have passed innovation consistency checks
|
||||
bool hgtCheckPassed = false; // boolean true if height measurements have passed innovation consistency check
|
||||
|
||||
// declare variables used to control access to arrays
|
||||
bool fuseData[6] = {false,false,false,false,false,false};
|
||||
|
@ -776,43 +776,47 @@ void NavEKF3_core::FuseVelPosNED()
|
|||
}
|
||||
}
|
||||
|
||||
// test height measurements
|
||||
// Test height measurements
|
||||
if (fuseHgtData) {
|
||||
// calculate height innovations
|
||||
// Calculate height innovations
|
||||
innovVelPos[5] = stateStruct.position.z - velPosObs[5];
|
||||
varInnovVelPos[5] = P[9][9] + R_OBS_DATA_CHECKS[5];
|
||||
// calculate the innovation consistency test ratio
|
||||
|
||||
// Calculate the innovation consistency test ratio
|
||||
hgtTestRatio = sq(innovVelPos[5]) / (sq(MAX(0.01f * (float)frontend->_hgtInnovGate, 1.0f)) * varInnovVelPos[5]);
|
||||
|
||||
// when on ground we accept a larger test ratio to allow
|
||||
// the filter to handle large switch on IMU bias errors
|
||||
// without rejecting the height sensor
|
||||
const float maxTestRatio = (PV_AidingMode == AID_NONE && onGround)? 3.0 : 1.0;
|
||||
// When on ground we accept a larger test ratio to allow the filter to handle large switch on IMU
|
||||
// bias errors without rejecting the height sensor.
|
||||
const float maxTestRatio = (PV_AidingMode == AID_NONE && onGround)? 3.0f : 1.0f;
|
||||
if (hgtTestRatio < maxTestRatio) {
|
||||
hgtCheckPassed = true;
|
||||
lastHgtPassTime_ms = imuSampleTime_ms;
|
||||
}
|
||||
|
||||
// fail if the ratio is > 1, but don't fail if bad IMU data
|
||||
hgtHealth = ((hgtTestRatio < maxTestRatio) || badIMUdata);
|
||||
|
||||
// Fuse height data if healthy or timed out or in constant position mode
|
||||
if (hgtHealth || hgtTimeout) {
|
||||
// Use height data if innovation check passed or timed out or if bad IMU data
|
||||
// Always fuse data if bad IMU to prevent aliasing and clipping pulling the state estimate away
|
||||
// from the measurement un-opposed if test threshold is exceeded.
|
||||
if (hgtCheckPassed || hgtTimeout || badIMUdata) {
|
||||
// Calculate a filtered value to be used by pre-flight health checks
|
||||
// We need to filter because wind gusts can generate significant baro noise and we want to be able to detect bias errors in the inertial solution
|
||||
if (onGround) {
|
||||
float dtBaro = (imuSampleTime_ms - lastHgtPassTime_ms)*1.0e-3f;
|
||||
float dtBaro = (imuSampleTime_ms - lastHgtPassTime_ms) * 1.0e-3f;
|
||||
const float hgtInnovFiltTC = 2.0f;
|
||||
float alpha = constrain_float(dtBaro/(dtBaro+hgtInnovFiltTC),0.0f,1.0f);
|
||||
hgtInnovFiltState += (innovVelPos[5]-hgtInnovFiltState)*alpha;
|
||||
float alpha = constrain_float(dtBaro/(dtBaro+hgtInnovFiltTC), 0.0f, 1.0f);
|
||||
hgtInnovFiltState += (innovVelPos[5] - hgtInnovFiltState)*alpha;
|
||||
} else {
|
||||
hgtInnovFiltState = 0.0f;
|
||||
}
|
||||
|
||||
// if timed out, reset the height
|
||||
if (hgtTimeout) {
|
||||
ResetHeight();
|
||||
|
||||
// Don't fuse the same data we have used to reset states.
|
||||
fuseHgtData = false;
|
||||
}
|
||||
|
||||
// If we have got this far then declare the height data as healthy and reset the timeout counter
|
||||
hgtHealth = true;
|
||||
lastHgtPassTime_ms = imuSampleTime_ms;
|
||||
} else {
|
||||
fuseHgtData = false;
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -828,7 +832,7 @@ void NavEKF3_core::FuseVelPosNED()
|
|||
fuseData[3] = true;
|
||||
fuseData[4] = true;
|
||||
}
|
||||
if (fuseHgtData && hgtHealth) {
|
||||
if (fuseHgtData) {
|
||||
fuseData[5] = true;
|
||||
}
|
||||
|
||||
|
|
Loading…