AP_Scripting: winch-control gets .md file

This commit is contained in:
Randy Mackay 2023-09-28 11:07:39 +09:00 committed by Peter Barker
parent e914c38cef
commit 28746e84ae
2 changed files with 20 additions and 0 deletions

View File

@ -0,0 +1,20 @@
# Winch Control
Allows the winch to be deployed or retracted at a fixed speed using an auxiliary switch
# Parameters
WINCH_RATE_UP : rate (in m/s) when retracting line
WINCH_RATE_DN : rate (in m/s) when deploying line
WINCH_RC_FUNC : RCn_OPTION number to use to control winch rate. Default is 300 (Scripting1)
# How To Use
1. set RCx_OPTION to 300 to enable controlling the winch rate from an auxiliary switch
2. set WINCH_RATE_UP to the fixed retract speed (in m/s)
3. set WINCH_RATE_DN to the fixed release speed (in m/s)
4. raise the RC auxiliary switch to retract the winch's line
5. lower the RC auxiliary switch to deploy the winch's line
6. center the RC auxiliary switch to stop the winch
Alternatively Mission Planner's Aux Function screen can be used in place of an actual RC switch