mirror of
https://github.com/ArduPilot/ardupilot
synced 2025-01-03 14:38:30 -04:00
AP_NavEKF2: fixed baro innovation gate when on ground with AIDING_NONE
when on the ground without a position source we would disable the innovation gate for the barometer. This meant that a single (or small number of) really bad baro readings would be fused into the EKF, causing it to destabilise Fixes #11903
This commit is contained in:
parent
8e095d4a81
commit
098701ec79
@ -602,10 +602,17 @@ void NavEKF2_core::FuseVelPosNED()
|
||||
varInnovVelPos[5] = P[8][8] + R_OBS_DATA_CHECKS[5];
|
||||
// calculate the innovation consistency test ratio
|
||||
hgtTestRatio = sq(innovVelPos[5]) / (sq(MAX(0.01f * (float)frontend->_hgtInnovGate, 1.0f)) * varInnovVelPos[5]);
|
||||
// fail if the ratio is > 1, but don't fail if bad IMU data
|
||||
hgtHealth = ((hgtTestRatio < 1.0f) || badIMUdata);
|
||||
|
||||
// when on ground we accept a larger test ratio to allow
|
||||
// the filter to handle large switch on IMU bias errors
|
||||
// without rejecting the height sensor
|
||||
const float maxTestRatio = (PV_AidingMode == AID_NONE && onGround)? 3.0 : 1.0;
|
||||
|
||||
// fail if the ratio is > maxTestRatio, but don't fail if bad IMU data
|
||||
hgtHealth = (hgtTestRatio < maxTestRatio) || badIMUdata;
|
||||
|
||||
// Fuse height data if healthy or timed out or in constant position mode
|
||||
if (hgtHealth || hgtTimeout || (PV_AidingMode == AID_NONE && onGround)) {
|
||||
if (hgtHealth || hgtTimeout) {
|
||||
// Calculate a filtered value to be used by pre-flight health checks
|
||||
// We need to filter because wind gusts can generate significant baro noise and we want to be able to detect bias errors in the inertial solution
|
||||
if (onGround) {
|
||||
|
Loading…