ardupilot/libraries/AP_Baro/AP_Baro_MS5611.cpp

252 lines
6.9 KiB
C++
Raw Normal View History

/// -*- tab-width: 4; Mode: C++; c-basic-offset: 4; indent-tabs-mode: nil -*-
/*
APM_MS5611.cpp - Arduino Library for MS5611-01BA01 absolute pressure sensor
Code by Jose Julio, Pat Hickey and Jordi Muñoz. DIYDrones.com
This library is free software; you can redistribute it and/or
modify it under the terms of the GNU Lesser General Public
License as published by the Free Software Foundation; either
version 2.1 of the License, or (at your option) any later version.
Sensor is conected to standard SPI port
Chip Select pin: Analog2 (provisional until Jordi defines the pin)!!
Variables:
Temp : Calculated temperature (in Celsius degrees * 100)
Press : Calculated pressure (in mbar units * 100)
Methods:
init() : Initialization and sensor reset
read() : Read sensor data and _calculate Temperature, Pressure and Altitude
This function is optimized so the main host don´t need to wait
You can call this function in your main loop
Maximum data output frequency 100Hz - this allows maximum oversampling in the chip ADC
It returns a 1 if there are new data.
get_pressure() : return pressure in mbar*100 units
get_temperature() : return temperature in celsius degrees*100 units
Internal functions:
_calculate() : Calculate Temperature and Pressure (temperature compensated) in real units
*/
#include <SPI.h>
#include "AP_Baro_MS5611.h"
/* on APM v.24 MS5661_CS is PG1 (Arduino pin 40) */
#define MS5611_CS 40
#define CMD_MS5611_RESET 0x1E
#define CMD_MS5611_PROM_Setup 0xA0
#define CMD_MS5611_PROM_C1 0xA2
#define CMD_MS5611_PROM_C2 0xA4
#define CMD_MS5611_PROM_C3 0xA6
#define CMD_MS5611_PROM_C4 0xA8
#define CMD_MS5611_PROM_C5 0xAA
#define CMD_MS5611_PROM_C6 0xAC
#define CMD_MS5611_PROM_CRC 0xAE
#define CMD_CONVERT_D1_OSR4096 0x48 // Maximum resolution (oversampling)
#define CMD_CONVERT_D2_OSR4096 0x58 // Maximum resolution (oversampling)
uint32_t AP_Baro_MS5611::_s_D1;
uint32_t AP_Baro_MS5611::_s_D2;
uint8_t AP_Baro_MS5611::_state;
uint32_t AP_Baro_MS5611::_timer;
bool AP_Baro_MS5611::_sync_access;
bool AP_Baro_MS5611::_updated;
uint8_t AP_Baro_MS5611::_spi_read(uint8_t reg)
{
uint8_t return_value;
uint8_t addr = reg; // | 0x80; // Set most significant bit
digitalWrite(MS5611_CS, LOW);
SPI.transfer(addr); // discarded
return_value = SPI.transfer(0);
digitalWrite(MS5611_CS, HIGH);
return return_value;
}
uint16_t AP_Baro_MS5611::_spi_read_16bits(uint8_t reg)
{
uint8_t byteH, byteL;
uint16_t return_value;
uint8_t addr = reg; // | 0x80; // Set most significant bit
digitalWrite(MS5611_CS, LOW);
SPI.transfer(addr); // discarded
byteH = SPI.transfer(0);
byteL = SPI.transfer(0);
digitalWrite(MS5611_CS, HIGH);
return_value = ((uint16_t)byteH<<8) | (byteL);
return return_value;
}
uint32_t AP_Baro_MS5611::_spi_read_adc()
{
uint8_t byteH,byteM,byteL;
uint32_t return_value;
uint8_t addr = 0x00;
digitalWrite(MS5611_CS, LOW);
SPI.transfer(addr); // discarded
byteH = SPI.transfer(0);
byteM = SPI.transfer(0);
byteL = SPI.transfer(0);
digitalWrite(MS5611_CS, HIGH);
return_value = (((uint32_t)byteH)<<16) | (((uint32_t)byteM)<<8) | (byteL);
return return_value;
}
void AP_Baro_MS5611::_spi_write(uint8_t reg)
{
digitalWrite(MS5611_CS, LOW);
SPI.transfer(reg); // discarded
digitalWrite(MS5611_CS, HIGH);
}
// Public Methods //////////////////////////////////////////////////////////////
// SPI should be initialized externally
bool AP_Baro_MS5611::init( AP_PeriodicProcess *scheduler )
{
2012-04-30 03:11:55 -03:00
scheduler->suspend_timer();
pinMode(MS5611_CS, OUTPUT); // Chip select Pin
digitalWrite(MS5611_CS, HIGH);
delay(1);
2012-02-14 12:55:32 -04:00
_spi_write(CMD_MS5611_RESET);
delay(4);
// We read the factory calibration
// The on-chip CRC is not used
C1 = _spi_read_16bits(CMD_MS5611_PROM_C1);
C2 = _spi_read_16bits(CMD_MS5611_PROM_C2);
C3 = _spi_read_16bits(CMD_MS5611_PROM_C3);
C4 = _spi_read_16bits(CMD_MS5611_PROM_C4);
C5 = _spi_read_16bits(CMD_MS5611_PROM_C5);
C6 = _spi_read_16bits(CMD_MS5611_PROM_C6);
//Send a command to read Temp first
_spi_write(CMD_CONVERT_D2_OSR4096);
_timer = micros();
_state = 1;
Temp=0;
Press=0;
2012-02-14 12:55:32 -04:00
2012-04-30 03:11:55 -03:00
scheduler->resume_timer();
scheduler->register_process( AP_Baro_MS5611::_update );
healthy = true;
return true;
}
// Read the sensor. This is a state machine
// We read one time Temperature (state=1) and then 4 times Pressure (states 2-5)
// temperature does not change so quickly...
void AP_Baro_MS5611::_update(uint32_t tnow)
{
if (_sync_access) return;
// Throttle read rate to 100hz maximum.
// note we use 9500us here not 10000us
// the read rate will end up at exactly 100hz because the Periodic Timer fires at 1khz
if (tnow - _timer < 9500) {
return;
}
_timer = tnow;
2012-02-14 12:55:32 -04:00
if (_state == 1) {
_s_D2 = _spi_read_adc(); // On state 1 we read temp
_state++;
_spi_write(CMD_CONVERT_D1_OSR4096); // Command to read pressure
} else if (_state == 5) {
_s_D1 = _spi_read_adc();
_state = 1; // Start again from state = 1
_spi_write(CMD_CONVERT_D2_OSR4096); // Command to read temperature
_updated = true; // New pressure reading
} else {
_s_D1 = _spi_read_adc();
_state++;
_spi_write(CMD_CONVERT_D1_OSR4096); // Command to read pressure
_updated = true; // New pressure reading
}
}
uint8_t AP_Baro_MS5611::read()
{
_sync_access = true;
bool updated = _updated;
_updated = 0;
if (updated > 0) {
D1 = _s_D1;
D2 = _s_D2;
_raw_press = D1;
_raw_temp = D2;
}
_sync_access = false;
_calculate();
if (updated) {
_last_update = millis();
}
return updated ? 1 : 0;
}
// Calculate Temperature and compensated Pressure in real units (Celsius degrees*100, mbar*100).
void AP_Baro_MS5611::_calculate()
{
int32_t dT;
int64_t TEMP; // 64 bits
int64_t OFF;
int64_t SENS;
int64_t P;
// Formulas from manufacturer datasheet
// as per data sheet some intermediate results require over 32 bits, therefore
// we define parameters as 64 bits to prevent overflow on operations
// sub -20c temperature compensation is not included
dT = D2-((long)C5*256);
TEMP = 2000 + ((int64_t)dT * C6)/8388608;
2012-02-14 12:55:32 -04:00
OFF = (int64_t)C2 * 65536 + ((int64_t)C4 * dT ) / 128;
SENS = (int64_t)C1 * 32768 + ((int64_t)C3 * dT) / 256;
if (TEMP < 2000){ // second order temperature compensation
int64_t T2 = (((int64_t)dT)*dT) >> 31;
int64_t Aux_64 = (TEMP-2000)*(TEMP-2000);
int64_t OFF2 = (5*Aux_64)>>1;
int64_t SENS2 = (5*Aux_64)>>2;
TEMP = TEMP - T2;
OFF = OFF - OFF2;
SENS = SENS - SENS2;
}
2012-02-14 12:55:32 -04:00
P = (D1*SENS/2097152 - OFF)/32768;
Temp = TEMP;
Press = P;
}
int32_t AP_Baro_MS5611::get_pressure()
{
return(Press);
}
int16_t AP_Baro_MS5611::get_temperature()
{
// callers want the temperature in 0.1C units
return(Temp/10);
}
int32_t AP_Baro_MS5611::get_raw_pressure() {
return _raw_press;
}
int32_t AP_Baro_MS5611::get_raw_temp() {
return _raw_temp;
}