2021-10-10 05:56:41 -03:00
|
|
|
#include "AP_BattMonitor_LTC2946.h"
|
|
|
|
#include <GCS_MAVLink/GCS.h>
|
|
|
|
#include <AP_HAL/utility/sparse-endian.h>
|
|
|
|
|
|
|
|
#if HAL_BATTMON_LTC2946_ENABLED
|
|
|
|
|
|
|
|
extern const AP_HAL::HAL& hal;
|
|
|
|
|
|
|
|
#define REG_CTRLA 0x00
|
|
|
|
#define REG_CTRLB 0x01
|
|
|
|
#define REG_STATUS 0x80
|
|
|
|
#define REG_MFR_ID 0xe7
|
|
|
|
|
|
|
|
// first byte of 16 bit ID is stable
|
|
|
|
#define ID_LTC2946 0x60
|
|
|
|
|
|
|
|
#define REG_DELTA 0x14 // 16 bits
|
|
|
|
#define REG_VIN 0x1e // 16 bits
|
|
|
|
|
|
|
|
#define REGA_CONF 0x18 // sense, alternate
|
|
|
|
#define REGB_CONF 0x01 // auto-reset
|
|
|
|
|
|
|
|
void AP_BattMonitor_LTC2946::init(void)
|
|
|
|
{
|
|
|
|
dev = hal.i2c_mgr->get_device(HAL_BATTMON_LTC2946_BUS, HAL_BATTMON_LTC2946_ADDR, 100000, false, 20);
|
|
|
|
if (!dev) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
uint8_t id = 0;
|
|
|
|
WITH_SEMAPHORE(dev->get_semaphore());
|
|
|
|
if (!dev->read_registers(REG_MFR_ID, &id, 1) || id != ID_LTC2946) {
|
|
|
|
GCS_SEND_TEXT(MAV_SEVERITY_WARNING, "LTC2946: Failed to find device 0x%04x", unsigned(id));
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (!dev->write_register(REG_CTRLA, REGA_CONF) ||
|
|
|
|
!dev->write_register(REG_CTRLB, REGB_CONF)) {
|
|
|
|
GCS_SEND_TEXT(MAV_SEVERITY_WARNING, "LTC2946: Failed to configure device");
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
// use datasheet typical values
|
|
|
|
voltage_LSB = 102.4 / 4095.0;
|
|
|
|
current_LSB = (0.1024/0.0005) / 4095.0;
|
|
|
|
|
|
|
|
GCS_SEND_TEXT(MAV_SEVERITY_WARNING, "LTC2946: found monitor on bus %u", HAL_BATTMON_LTC2946_BUS);
|
|
|
|
|
|
|
|
if (dev) {
|
|
|
|
dev->register_periodic_callback(25000, FUNCTOR_BIND_MEMBER(&AP_BattMonitor_LTC2946::timer, void));
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
/// read the battery_voltage and current, should be called at 10hz
|
|
|
|
void AP_BattMonitor_LTC2946::read(void)
|
|
|
|
{
|
|
|
|
WITH_SEMAPHORE(accumulate.sem);
|
|
|
|
_state.healthy = accumulate.count > 0;
|
|
|
|
if (!_state.healthy) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
_state.voltage = accumulate.volt_sum / accumulate.count;
|
|
|
|
_state.current_amps = accumulate.current_sum / accumulate.count;
|
|
|
|
accumulate.volt_sum = 0;
|
|
|
|
accumulate.current_sum = 0;
|
|
|
|
accumulate.count = 0;
|
|
|
|
|
|
|
|
const uint32_t tnow = AP_HAL::micros();
|
2022-03-22 21:01:25 -03:00
|
|
|
const uint32_t dt_us = tnow - _state.last_time_micros;
|
2021-10-10 05:56:41 -03:00
|
|
|
|
|
|
|
// update total current drawn since startup
|
2022-03-22 21:01:25 -03:00
|
|
|
update_consumed(_state, dt_us);
|
|
|
|
|
2021-10-10 05:56:41 -03:00
|
|
|
_state.last_time_micros = tnow;
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
read word from register
|
|
|
|
returns true if read was successful, false if failed
|
|
|
|
*/
|
|
|
|
bool AP_BattMonitor_LTC2946::read_word(const uint8_t reg, uint16_t& data) const
|
|
|
|
{
|
|
|
|
// read the appropriate register from the device
|
|
|
|
if (!dev->read_registers(reg, (uint8_t *)&data, sizeof(data))) {
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
|
|
|
// convert byte order
|
|
|
|
data = uint16_t(be16toh(uint16_t(data)));
|
|
|
|
|
|
|
|
// return success
|
|
|
|
return true;
|
|
|
|
}
|
|
|
|
|
|
|
|
void AP_BattMonitor_LTC2946::timer(void)
|
|
|
|
{
|
|
|
|
uint16_t amps, volts;
|
|
|
|
if (!read_word(REG_DELTA, amps) ||
|
|
|
|
!read_word(REG_VIN, volts)) {
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
WITH_SEMAPHORE(accumulate.sem);
|
|
|
|
// convert 12 bit ADC data
|
|
|
|
accumulate.volt_sum += (volts>>4) * voltage_LSB;
|
|
|
|
accumulate.current_sum += (amps>>4) * current_LSB;
|
|
|
|
accumulate.count++;
|
|
|
|
}
|
|
|
|
|
|
|
|
#endif // HAL_BATTMON_LTC2946_ENABLED
|